Features
Regulated
Converters
●
●
●
●
●
●
●
●
Compact 40W AC-DC Power Supply
Universal Input Voltage Range
4000VAC Isolation, Low Leakage Current
Low Output Ripple and Noise
Short Circuit Protected
Triple Output with Independent Outputs
UL-60601 Certified for Medical Applications
CE Marked
POWERLINE
AC/DC-Converter
with 3 year Warranty
Selection Guide
Part
Number
RAC40-3.3SA
RAC40-05SA
RAC40-12SA
RAC40-15SA
RAC40-24SA
RAC40-05DA
RAC40-12DA
RAC40-15DA
RAC40-0512TA
RAC40-0515TA
Input
Range
(VAC)
90-264
90-264
90-264
90-264
90-264
90-264
90-264
90-264
Output
Voltage
(VDC)
3.3
5
12
15
24
Output
Current
(mA)
8000
8000
3333
2666
1667
Efficiency
(%)
76
79
83
83
83
Max.
Capacitive
Load
70000µF
33000µF
4000µF
3000µF
1200µF
RAC40-0512DA
NOT RECOMMENDED
FOR
NEW DESIGNS
±5
±4000
80
±12
±15
±1666
±1333
83
83
90-264
90-264
90-264
5/12
5000/1250
80
79
79
5/±12
5/±15
+5000/±600
+5000/±500
40 Watt
Single/Dual,
Double
&
Triple Output
±6000µF
±1000µF
±2000µF
15000/750µF
18000/±150µF
18000/±400µF
2002/95/EC
6/6
*add suffix “-E” for extended temperature range, e.g. RAC40-05SA-E
*add suffix "-ST” for screw terminal module e.g. RAC40-05SA-ST, RAC40-05DA-ST, RAC40-0512TA-ST
RoHS
Specifications
(typical at 25°C and after warm up time unless otherwise specified )
Input Voltage Range
90-264VAC or 100-370VDC
Rated Power
40 Watts max.
Input Frequency Range (for AC Input)
47-440Hz
Input Current (full load)
115VAC/230VAC
860mA/ 460mA max.
No Load Power Consumption
115VAC/230VAC
720mW max.
Inrush Current (<2ms)
115VAC/230VAC
10A / 20A max.
Leakage Current
115VAC/230VAC
100µA/ 200µA max.
Output Voltage Accuracy (Full load)
Single, Dual Outputs ±2% typ.
(note 2)
Others: Main Output ±3% typ., Secondary Output(s) ±5% typ.
Line Voltage Regulation (low line, high line at full load )
Single, Dual Outputs ±0.5% typ.
Double&Triple: Main Output ±0.5% typ., Secondary Output(s) ±5% typ.
Load Voltage Regulation (10% to 100% symmetric load )
Single, Dual O!utputs ±1% typ.
Double: Main Output 2% typ., Secondary Output 6% typ.
Triple: Main Output ±3% typ., Secondary Output(s) ±7% typ.
Cross Regulation
Dual
±5% typ.
Double
Main Output 1%, Secondary Output 7% typ.
Triple
Main Output ±3%, Secondary Output ±7% typ.
Output Ripple and Noise
3.3V Output
50mVp-p max.
(20MHz limited, 0.1µF and 47µF across outputs)
Others
1% Vout max.
Operating Frequency
132kHz typ.
RMS Isolation Voltage (input to output)
4kVAC / 1 minute
Temperature Coefficient
±0.01%/°C typ.
Isolation Resistance
100 MΩ min.
Short Circuit Protection
Continuous, Automatic Restart
Overcurrent Protection
105% typ.
Over Temeperature Protection
100°C
Operating Temperature Range
Standard
-25°C to +70°C
(free air convection, with derating)
Suffix -E
-40°C to +70°C
Storage Temperature Range
-40°C to +100°C
Humidity
95% max.
continued on next page
PA-30
REV: 0/2012
E314885
UL-60601-1 Certified
RAC40-A
RAC40-A
Description
Compact switching power module for PCB or
DIN-rail mounting with medical certification
UL-60601-1.
Derating Graph
(Ambient Temperature)
125
100
Output Power (%)
75
50
25
0
-40 -25 -10 0
60 70 80 90
E-Version
Natural Convection
50
Ambient Temperature Range (°C)
Please Read Application Notes
www.recom-electronic.com
POWERLINE
AC/DC-Converter
Specifications
continued
Case Material
Package Weight
suffix (-ST)
Packing Quantity
EMC
MTBF (+25°C)
using MIL-HDBK-217F
RAC40-S_D_TA
Series
Epoxy with Fibreglass (UL94V-0)
280g
300g
5 pcs (-ST Version: 1 pc)
EN 55011 Class B / EN60601-1-2
200~400 x 10
3
hours
Screw Terminal Module Option (suffix -ST)
32.5
3rd angle
projection
5.5
Removable DIN-Rail
Mounting Bracket
Pin Connections
Pin #
Single Out
NC
VAC in (L)
VAC in (N)
+VDC out
NC
-VDC out
NC
NC
Dual Out
NC
VAC in (L)
VAC in (N)
+VDC out
NC
Com
NC
-VDC out
Double Out
NC
VAC in (L)
VAC in (N)
+12V Out
+5V Out
+12V Rtn
+5V Rtn
NC
Triple Out
NC
VAC in (L)
VAC in (N)
+VDC out
+5V Out
Com
+5V Rtn
-VDC out
1
2
3
Fuse
RAC40-xxS_D_TA
4
5
6
7
8
1
2
50.0
63.7
3
4
5
6
7
100.0
111.9
8
RAC40-A
NC = No Connection
Package Style and Pinning
89.0
63.5
3rd angle
projection
27.00
6.0
81.30
1.2
Pin Connections
Pin #
Single Out
VAC in (L)
VAC in (N)
+VDC out
No Pin
-VDC out
No Pin
NC
Dual Out
VAC in (L)
VAC in (N)
+VDC out
No Pin
Com
No Pin
-VDC out
Double Out
VAC in (L)
VAC in (N)
+12V Out
+5V Out
+12V Rtn
+5V Rtn
No Pin
Triple Out
VAC in (L)
VAC in (N)
+VDC out
+5V Out
Vout Com
+5V Rtn
-VDC out
2
7
6
15.24
12.7
1
2
3
4
5
Tolerance =± 0.5 mm
6
7
55.88
Bottom View
5
12.7
4
15.24
1
3
Notes
Note 1: Suggested input fuse rating 3.15A Slow Blow.
Note2: Triple output version has +/-Vout common that is not connected to +5V Return pin internally.
www.recom-international.com
REV:0/2012