EEWORLDEEWORLDEEWORLD

Part Number

Search

DA22912111

Description
AC Power Entry Modules PCB 1A 125/250VAC
CategoryThe connector   
File Size559KB,6 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Parametric Compare View All

DA22912111 Online Shopping

Suppliers Part Number Price MOQ In stock  
DA22912111 - - View Buy Now

DA22912111 Overview

AC Power Entry Modules PCB 1A 125/250VAC

DA22912111 Parametric

Parameter NameAttribute value
Product CategoryAC Power Entry Modules
ManufacturerSCHURTER
RoHSDetails
ProductInlets
FilteredFiltered
FusedYes
Switch FunctionNot Switched
Current Rating10 A
Voltage Rating250 VAC
Mounting StyleScrew
Termination StyleQuick Connect
Connector TypeC-14
Flammability RatingUL 94 V-0
Housing MaterialThermoplastic
Factory Pack Quantity20
Unit Weight2.292808 oz
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
DA22
IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, for PCB Mounting
C14
70° C
Approvals and Compliances
Description
- Panel Mount :
Screw-on mounting on PCB , from rear-side
- 3 Functions :
Appliance Inlet , Fuseholder for fuse-links 5 x 20 mm , Line filter in
standard and medical version
- V-Lock notch standard
- PCB terminals
Characteristics
-
-
-
-
Ultra-compact design
All single elements are already wired
For added safety "Extra-Safe" fuse drawers are available
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Fixing on PCB with self-tapping screws 3 mm or pre-inserted nuts M3
Fuse drawer 1-pole, plus spare fuse case
Fuse drawer 2-pole, with shorting bar
Medical version M80, 220 nF X capacitors
Class X1- and Y1-capacitors for enhanced withstand voltage
Protection class II, 70°C
Other versions on request
-
-
-
-
-
-
References
Weblinks
Alternative: version for panel mounting
KFA
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product, Microsite
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 250 VAC;
50/60 Hz ¹⁾
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (1 min/50 Hz)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
For PCB mounting ; Additional for
ground terminal: Quick connect termi-
nals 6.3 x 0.8 mm angled to pin axis
Screw-on mounting: max 3 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
C14 acc. to IEC 60320-1
UL 498 CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.4 W (2-pole) per
pole
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 2'000'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Tempe-
rature
Climatic Category
IP-Protection
Protection Class
Terminal
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Filter
MTBF
Panel Thickness S
Material: Housing
1)
UL appovals: 1-pole versions up to 10 A, 2-pole versions up to 8 A
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
EMC Products
1

DA22912111 Related Products

DA22912111 DA22612111 DA22832111 DA22112111 DA22232111 DA22432111 DA22632111 DA22932111
Description AC Power Entry Modules PCB 1A 125/250VAC AC Power Entry Modules PCB 1A 125/250VAC AC Power Entry Modules PCB 1A 125/250VAC AC Power Entry Modules PCB 1A 125/250VAC AC Power Entry Modules PCB 1A 125/250VAC AC Power Entry Modules PCB 1A 125/250VAC AC Power Entry Modules PCB 1A 125/250VAC
Product Category AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules
Manufacturer SCHURTER SCHURTER SCHURTER SCHURTER SCHURTER SCHURTER SCHURTER SCHURTER
RoHS Details Details Details Details Details Details Details Details
Product Inlets Inlets Inlets Inlets Inlets Inlets Inlets Inlets
Filtered Filtered Filtered Filtered Filtered Filtered Filtered Filtered Filtered
Fused Yes Yes Yes Yes Yes Yes Yes Yes
Switch Function Not Switched Not Switched Not Switched Not Switched Not Switched Not Switched Not Switched Not Switched
Current Rating 10 A 6 A 8 A 1 A 2 A 4 A 6 A 10 A
Voltage Rating 250 VAC 250 VAC 250 VAC 250 VAC 250 VAC 250 VAC 250 VAC 250 VAC
Mounting Style Screw Screw Screw Screw Screw Screw Screw Screw
Termination Style Quick Connect Quick Connect Quick Connect Quick Connect Quick Connect Quick Connect Quick Connect Quick Connect
Connector Type C-14 C-14 C-14 C-14 C-14 C-14 C-14 C-14
Flammability Rating UL 94 V-0 UL 94 V-0 UL 94 V-0 UL 94 V-0 UL 94 V-0 UL 94 V-0 UL 94 V-0 UL 94 V-0
Housing Material Thermoplastic Thermoplastic Thermoplastic Thermoplastic Thermoplastic Thermoplastic Thermoplastic Thermoplastic
Factory Pack Quantity 20 20 20 20 20 20 20 20
Unit Weight 2.292808 oz 2.292808 oz 2.292808 oz 2.292808 oz 2.292808 oz 2.292808 oz 2.292808 oz 2.292808 oz
[Vishay special post] Try Vishay gadgets and grab a travel set for your trip. If you want to grab it, grab it. Don’t hesitate.
[size=4]Event Date: From now on - Ends at 12:00:00 on May 20, 2015 Event Protagonist: [url=https://www.eeworld.com.cn/huodong/201501_Vishay/][color=#000][font=宋体]Vishay's new "IHLP Core Loss Calculato...
EEWORLD社区 Analog electronics
The task cannot be looped.
These are two programs. I run them directly using Keil's simulation and they will jump back and forth. 0; // SYSCLK_Init (); // SYSCLK_INIT () PORT_Init (); // SYSCLK_INIT () PORT_Init (); // SYSCLK_I...
似是而非君 Real-time operating system RTOS
The entire process of automobile design and manufacturing
For most people, the appreciation of cars is basically the whole car. In addition to performance, the appearance and interior of the car are the most talked about topics, because this is the most intu...
clj2004000 Automotive Electronics
Answer all the questions and get a 50-yuan Jingdong shopping voucher: Microchip's pre-Christmas carnival event at element11
[size=4] [/size] {:1_123:}Discover benefits for forum users, grab them when you see them. [size=5][b]Event date: now - December 24[/b][/size] [b][size=5]Answer a question and get a 50 yuan Jingdong co...
EEWORLD社区 Microchip MCU
MSP430 ECG Digital Wireless Telemetry System
[color=#000][font=宋体][size=12px] The market for wireless telemetry products is developing rapidly. Recently, the industry has also set off a revolution in wireless applications. Wireless telemetry tec...
Jacktang Microcontroller MCU
Questions about ccsv8
Why does the program always show that the file cannot be opened when entering data? How can I solve this problem?...
江冰雄 MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1037  2092  910  683  931  21  43  19  14  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号