EEWORLDEEWORLDEEWORLD

Part Number

Search

DA22832111

Description
AC Power Entry Modules PCB 1A 125/250VAC
CategoryThe connector   
File Size559KB,6 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Parametric Compare View All

DA22832111 Online Shopping

Suppliers Part Number Price MOQ In stock  
DA22832111 - - View Buy Now

DA22832111 Overview

AC Power Entry Modules PCB 1A 125/250VAC

DA22832111 Parametric

Parameter NameAttribute value
Product CategoryAC Power Entry Modules
ManufacturerSCHURTER
RoHSDetails
ProductInlets
FilteredFiltered
FusedYes
Switch FunctionNot Switched
Current Rating8 A
Voltage Rating250 VAC
Mounting StyleScrew
Termination StyleQuick Connect
Connector TypeC-14
Flammability RatingUL 94 V-0
Housing MaterialThermoplastic
Factory Pack Quantity20
Unit Weight2.292808 oz
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
DA22
IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, for PCB Mounting
C14
70° C
Approvals and Compliances
Description
- Panel Mount :
Screw-on mounting on PCB , from rear-side
- 3 Functions :
Appliance Inlet , Fuseholder for fuse-links 5 x 20 mm , Line filter in
standard and medical version
- V-Lock notch standard
- PCB terminals
Characteristics
-
-
-
-
Ultra-compact design
All single elements are already wired
For added safety "Extra-Safe" fuse drawers are available
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Fixing on PCB with self-tapping screws 3 mm or pre-inserted nuts M3
Fuse drawer 1-pole, plus spare fuse case
Fuse drawer 2-pole, with shorting bar
Medical version M80, 220 nF X capacitors
Class X1- and Y1-capacitors for enhanced withstand voltage
Protection class II, 70°C
Other versions on request
-
-
-
-
-
-
References
Weblinks
Alternative: version for panel mounting
KFA
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product, Microsite
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 250 VAC;
50/60 Hz ¹⁾
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (1 min/50 Hz)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
For PCB mounting ; Additional for
ground terminal: Quick connect termi-
nals 6.3 x 0.8 mm angled to pin axis
Screw-on mounting: max 3 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
C14 acc. to IEC 60320-1
UL 498 CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.4 W (2-pole) per
pole
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 2'000'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Tempe-
rature
Climatic Category
IP-Protection
Protection Class
Terminal
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Filter
MTBF
Panel Thickness S
Material: Housing
1)
UL appovals: 1-pole versions up to 10 A, 2-pole versions up to 8 A
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
EMC Products
1

DA22832111 Related Products

DA22832111 DA22612111 DA22112111 DA22232111 DA22432111 DA22912111 DA22632111 DA22932111
Description AC Power Entry Modules PCB 1A 125/250VAC AC Power Entry Modules PCB 1A 125/250VAC AC Power Entry Modules PCB 1A 125/250VAC AC Power Entry Modules PCB 1A 125/250VAC AC Power Entry Modules PCB 1A 125/250VAC AC Power Entry Modules PCB 1A 125/250VAC AC Power Entry Modules PCB 1A 125/250VAC
Product Category AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules
Manufacturer SCHURTER SCHURTER SCHURTER SCHURTER SCHURTER SCHURTER SCHURTER SCHURTER
RoHS Details Details Details Details Details Details Details Details
Product Inlets Inlets Inlets Inlets Inlets Inlets Inlets Inlets
Filtered Filtered Filtered Filtered Filtered Filtered Filtered Filtered Filtered
Fused Yes Yes Yes Yes Yes Yes Yes Yes
Switch Function Not Switched Not Switched Not Switched Not Switched Not Switched Not Switched Not Switched Not Switched
Current Rating 8 A 6 A 1 A 2 A 4 A 10 A 6 A 10 A
Voltage Rating 250 VAC 250 VAC 250 VAC 250 VAC 250 VAC 250 VAC 250 VAC 250 VAC
Mounting Style Screw Screw Screw Screw Screw Screw Screw Screw
Termination Style Quick Connect Quick Connect Quick Connect Quick Connect Quick Connect Quick Connect Quick Connect Quick Connect
Connector Type C-14 C-14 C-14 C-14 C-14 C-14 C-14 C-14
Flammability Rating UL 94 V-0 UL 94 V-0 UL 94 V-0 UL 94 V-0 UL 94 V-0 UL 94 V-0 UL 94 V-0 UL 94 V-0
Housing Material Thermoplastic Thermoplastic Thermoplastic Thermoplastic Thermoplastic Thermoplastic Thermoplastic Thermoplastic
Factory Pack Quantity 20 20 20 20 20 20 20 20
Unit Weight 2.292808 oz 2.292808 oz 2.292808 oz 2.292808 oz 2.292808 oz 2.292808 oz 2.292808 oz 2.292808 oz
How to create a folder under vxworks operating system?
As the title says, I used the system function and found that I could not create a folder. Forum friends, do you know how to create it?...
newnew0601 Real-time operating system RTOS
A question from a WinCE novice: Why is there only WinCE6.0 Test Kit and nothing else after I installed WinCE6.0?
After I installed WinCE6.0, there was only WinCE6.0 Test Kit in the program start menu, nothing else, no Platformbuilder6.0. I did find pb6 in the Tools of VS2005, but how to use it is still a problem...
mr.luoli Embedded System
I received the prize for the 51 essay contest~~[Portable speaker] Unboxing photos~~~~[Updated disassembly photos!!]
First of all, thanks to the forum, thanks to Xiaobai~~~~ HeheNo more nonsense, here are the photos!!!First, a family photo~Unfortunately, one of the speakers seems to have been hit... but it's not a b...
anqi90 51mcu
Modeim simulation advice!
Error: (vsim-SDF-3250) test10_vhd.sdo(39): Failed to find INSTANCE '\q[0]~I\'.# ** Error: (vsim-SDF-3250) test10_vhd.sdo(39): Failed to find INSTANCE 'asynch_inst'.# ** Error: (vsim-SDF-3250) test10_v...
简小韬韬 FPGA/CPLD
How to contact if I cannot receive the discounted product I bought from ti estore?
I used FedEx to send the items I sold at TI estore to China. I changed the address twice and they still didn't deliver it. It shows that the address is wrong. How can I contact them?...
7leaves TI Technology Forum

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1842  2730  932  1634  1791  38  55  19  33  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号