Part Number

Search

2026-25-C2

Description
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Sparkover100V/s 250V 3 Pole
CategoryWireless rf/communication    Telecom circuit   
File Size620KB,4 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Environmental Compliance
Download Datasheet Parametric View All

2026-25-C2 Online Shopping

Suppliers Part Number Price MOQ In stock  
2026-25-C2 - - View Buy Now

2026-25-C2 Overview

Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Sparkover100V/s 250V 3 Pole

2026-25-C2 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codeunknown
Factory Lead Time5 weeks
JESD-30 codeO-XXSS-P3
Number of functions1
Number of terminals3
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
Package body materialUNSPECIFIED
Package shapeROUND
Package formSPECIAL SHAPE
Certification statusNot Qualified
surface mountNO
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Temperature levelOTHER
Terminal formPIN/PEG
Terminal locationUNSPECIFIED
Base Number Matches1
*R
oH
VE S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
n
Balanced TRIGARD
®
n
Approximately 8 mm diameter, 11 mm long
n
UL Recognized
n
Custom configurations available
n
High surge current rating
n
Stable breakdown throughout life
M
PL
IA
Applications
n
Telecommunications
n
Industrial electronics
n
Commercial electronics
n
Consumer electronics
n
Automotive, aircraft, military electronics
n
RoHS compliant* version available
NT
Characteristics
LE
AD
F
RE
E
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
(1)
100 V/µs
1000 V/µs
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
(1)
100 V/µs
1000 V/µs
(1)
*R
oH
S
CO
2026 Series - 3-Pole Gas Discharge Tube
Model No.
2026-09
90 V
275 V
600 V
2026-15
150 V
Ro VE LEA
HS RS D
C ION FRE
OM S E
PL AR
IA E
NT
*
2026-07
75 V
275 V
700 V
2026-20
200 V
425 V
625 V
2026-40
400 V
675 V
925 V
2026-23
230 V
450 V
650 V
2026-42
420 V
725 V
1000 V
2026-25
250 V
475 V
700 V
2026-47
470 V
800 V
1100 V
2026-26
260 V
475 V
700 V
2026-60
600 V
925 V
1250 V
350 V
575 V
Model No.
2026-30
300 V
550 V
775 V
2026-35
350 V
625 V
875 V
Impulse Sparkover voltage is defined as typical values of distribution.
Impulse Transverse Delay.............................................1000 V/µs ................................................................. < 75 ns
Insulation Resistance ...................................................100 V (50 V for Model 2026–07 & 2026-09) ............. > 10
10
Ω
Glow Voltage ................................................................10 mA ....................................................................... ~ 70 V
Arc Voltage ...................................................................1A ............................................................................. ~ 10 V
Glow-Arc Transition Current ........................................................................................................................... < 0.5 A
Capacitance .................................................................1 MHz ....................................................................... < 2 pF
DC Holdover Voltage
(2)
...............................................>135 V, (52 V for Model 2026-07 & 2026-09, ........... < 150 ms
80 V for Model 2026-15)
Impulse Discharge Current ...........................................40000 A, 8/20 µs
(3)
.................................................. 1 operation minimum
20000 A, 8/20 µs ...................................................... > 10 operations
5000 A, 10/350 µs ................................................... 1 operation
1000 A, 10/1000 µs ................................................. > 400 operations
Alternating Discharge Current ......................................130 Arms, 11 cycles
(3)
............................................. 1 operation minimum
20 Arms, 1 s ............................................................. > 10 operations
Operation and Storage Temperature .............................................................................................................. -40 to +90 °C
Climatic Category (IEC 60068-1) .................................................................................................................... 40/ 90/ 21
Moisture Sensitivity Level ............................................................................................................................... 1
ESD Classification (HBM) ............................................................................................................................... 6
An optional Switch-Grade Fail-Short device is available. The optional Fail-Short assembly will activate at a temperature of 215 °C – 217 °C
to provide a high conductive path to ground in case of a thermal overload. GDTs equipped with the optional Fail-Short device should be
soldered either manually at a temperature that is below the activation temperature of the Fail-Short mechanism, or using a selective soldering
process that does not exceed 210 °C.
Notes:
• Model number marking on tube: 26-xxx V.
• The rated discharge current for TRIGARD
®
Gas Discharge Tubes is the total current equally divided between each line to ground.
• Sparkover limits after life ±25 %, IR >108Ω (-25 %,+30 % for Model 2026-07, 2026-09 and 2026-60).
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859
(2)
(3)
Network applied.
DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Basic knowledge of LED backlight
[hide] 1. Technology of light source module:   The core technology of light source module is the optical technology of light guide plate. At present, there are mainly two types of light guide plates: ...
探路者 LED Zone
Cable colors are subject to national standards and must be enforced. Did you know that
[b] In industrial and civil electricity, transmission cables must be marked with various colors. Are there any special regulations for these colorful cable colors? [/b] [b] Is it a mandatory requireme...
qwqwqw2088 Analogue and Mixed Signal
CC2430 and other TI series chips SPI communication program writing
This article introduces how to configure SPI for TI chips such as cc2430. The content is quite detailed~~...
吸铁石上 RF/Wirelessly
Could you please tell me what is the function of the NL27WZ04 chip?
May I ask the experts what is the function of the NL27WZ04 chip? Does it have a plastic surgery function? Thank you...
wcht304 Analog electronics
Analog electronics learning
Uc is the control voltage. When Uc is high, the MOS tube is turned on when it is closed; when Uc is low, the MOS tube is turned off when it is open. Question: What are the functions of the diode, capa...
whwshiyuan1984 Analog electronics
NUCLEO Smart Home Gateway Solution Concept
Recently, I have been studying smart home and have been considering the implementation of home gateway. [size=3]There are two main solutions that I can think of. One is that the gateway builds its own...
通宵敲代码 DIY/Open Source Hardware

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2592  2297  1174  1566  1484  53  47  24  32  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号