EEWORLDEEWORLDEEWORLD

Part Number

Search

SF1050-10/01

Description
Mains Power Connector, 10A, 250VAC, Male
CategoryThe connector    The connector   
File Size80KB,1 Pages
ManufacturerDIALIGHT
Websitehttps://www.dialight.com
Download Datasheet Parametric Compare View All

SF1050-10/01 Overview

Mains Power Connector, 10A, 250VAC, Male

SF1050-10/01 Parametric

Parameter NameAttribute value
MakerDIALIGHT
Reach Compliance Codeunknown
Other featuresSTANDARDS: IEC 320; CSA; VDE, FASTON
Connector typeMAINS POWER CONNECTOR
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings10A, 250VAC
Manufacturer's serial numberSF1050
Installation typePANEL
OptionsGENERAL PURPOSE
Total number of contacts3
Base Number Matches1
SF 1050
1 & 3 AMP STANDARD
db
db
COMPACT GENERAL PURPOSE IEC INLET FILTER
‘M’ VERSION FOR MEDICAL APPLICATIONS
6 & 10 AMP STANDARD
90
90
80
70
60
50
40
30
20
10
.1
.15
.4
1
4
10
Frequency MHz
40
100
500
SYMMETRIC
80
70
60
50
40
30
SYMMETRIC
ASYMMETRIC
20
10
.1
.15
.4
1
ASYMMETRIC
4
10
Frequency MHz
40
100
500
1 & 3 AMP MEDICAL
db
db
6 & 10 AMP MEDICAL
90
90
80
70
60
50
40
30
20
10
.1
.15
SYMMETRIC
80
70
60
50
40
30
SYMMETRIC
ASYMMETRIC
.4
1
4
10
Frequency MHz
40
100
500
20
10
.1
.15
.4
ASYMMETRIC
1
4
10
Frequency MHz
40
100
500
SF 1050
Rated
Current A
Leakage Current
@ 250V 50Hz
Inductance
mH
Connections
Input
Output
Resistor
Value MΩ
Approvals
Standard Version
SF 1050-1/01
SF 1050-3/01
SF 1050-6/01
SF 1050-10/01
Medical Version
SF 1050M-1/01
SF 1050M-3/01
SF 1050M-6/01
SF 1050M-10/01
1
3
6
10
1
3
6
10
0.2mA max
0.2mA max
0.2mA max
0.2mA max
5µA max
5µA max
5µA max
5µA max
3.0
0.85
0.35
0.16
3.0
0.85
0.35
0.16
IEC 320
IEC 320
IEC 320
IEC 320
IEC 320
IEC 320
IEC 320
IEC 320
6.3 x 0.8 Faston
6.3 x 0.8 Faston
6.3 x 0.8 Faston
6.3 x 0.8 Faston
6.3 x 0.8 Faston
6.3 x 0.8 Faston
6.3 x 0.8 Faston
6.3 x 0.8 Faston
Not Fitted
Not Fitted
Not Fitted
Not Fitted
1
1
1
1
s
s
s
s
s
s
s
s
s
Approved
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
Temperature Range:
-25
0
C to +85
0
C
Operating Voltage:
250Vac
Operating Frequency:
0 to 400Hz
Test Voltage:
L+N to ground, 2700Vdc,
2 seconds
Submitted for Approval
IEC 950
(EN 60950 Applications)
DIMENSIONS
All dimensions are nominal and in mm
5.7
48
10.5
40
28.5
PANEL
CUT OUT
40
22.5
ø3.6
50
3.5R
3.8
34.5
21
FRONT AND REAR MOUNTING
CIRCUIT DIAGRAMS
Standard Version
L
LINE
E
N
0.047µF (x2)
Medical Version (Suffix ‘M’)
L1
L
LOAD
LINE
E
N
L1
2x2200pF (Y)
L
1MΩ
E
L1
L
LOAD
E
N
0.047µF (x2)
N
L1
14
FOR MORE INFORMATION PLEASE PHONE
01638 665161

SF1050-10/01 Related Products

SF1050-10/01 SF1050-1/01 SF1050M-1/01 SF1050M-10/10
Description Mains Power Connector, 10A, 250VAC, Male 1A, 250VAC, MALE, MAINS POWER CONNECTOR 1A, 250VAC, MALE, MAINS POWER CONNECTOR Mains Power Connector, 10A, 250VAC, Male
Maker DIALIGHT DIALIGHT DIALIGHT DIALIGHT
Reach Compliance Code unknown unknown unknown unknown
Other features STANDARDS: IEC 320; CSA; VDE, FASTON STANDARDS: IEC 320; CSA; VDE, FASTON STANDARDS: IEC 320; CSA; VDE, FASTON STANDARDS: IEC 320; CSA; VDE, FASTON
Connector type MAINS POWER CONNECTOR MAINS POWER CONNECTOR MAINS POWER CONNECTOR MAINS POWER CONNECTOR
Contact point gender MALE MALE MALE MALE
Coupling type SNAP SNAP SNAP SNAP
DIN compliance NO NO NO NO
IEC compliance YES YES YES YES
MIL compliance NO NO NO NO
Power Connector Ratings 10A, 250VAC 1A, 250VAC 1A, 250VAC 10A, 250VAC
Manufacturer's serial number SF1050 SF1050 SF1050M SF1050M
Installation type PANEL PANEL PANEL PANEL
Options GENERAL PURPOSE GENERAL PURPOSE GENERAL PURPOSE GENERAL PURPOSE
Total number of contacts 3 3 3 3
How is the output V0 of this op amp derived?
How is the output V0 of this op amp derived?...
QWE4562009 Integrated technical exchanges
Is there any microcontroller training in Suzhou?
MCU assembly language programmer    The CPC Central Committee and the State Council have vigorously promoted the labor preparation system, strictly implemented the employment access system and impleme...
dzpx MCU
About the clock setting of IIC in STM32F051 firmware library IIC
Now I want to use the IIC in the firmware library of F0. But I found a problem in it, that is, I can't calculate the clock setting of IIC. There is an official calculation tool. There is a line in the...
dwlovehome stm32/stm8
Why are the footprints I draw myself using ad10 different from those drawn using the footprint wizard?
[table=98%] [tr][td]I drew a stm32f103rbt6. According to the datasheet, its chip body, that is, the black part of the chip, is a 10*10 square. At this time, I drew a 10*10 square on the silk screen la...
伊森亨特 PCB Design
Solution to circuit failure of self-resettable fuse in LED products
Solution to the problem and feasibility analysis: The solution to the problem can be a self-recovery fuseIf a resettable fuse is used for protection, the result will be different. From the principle, ...
keeptops Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2498  2121  2016  523  1463  51  43  41  11  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号