Ultraviolet selective thin film sensor
TW30SX
Features of the TW30SX UV Sensor
The UV Sensor TW30SX is our Big Seller. Our customers treasure it’s broad application
range, it’s high reliability and robustness and it’s competitive price. Overview on the
advantages:
•
•
•
•
•
Broad Band UVA – UVB spectral response
Hermetically sealed metal housing and UV-glass window
high photocurrent even if illuminated with very low radiation because of big active area.
optimally suited for inexpensive sun dosimetry
we
are able to manufacture up to 2.000.000 pcs. per year.
Was leistet der TW30SX UV-Sensor?
Der UV-Sensor TW30SX ist unserer Verkaufsrenner. Unsere Kunden schätzen seine
Universalität, seine Zuverlässigkeit, Robustheit und seinen günstigen Preis. Die Vorteile auf
einen Blick:
•
•
•
•
•
Breitband UVA – UVB Messspektrum
Hermetisch dichtes Metallgehäuse mit UV-Glasfenster
Großer Photostrom auch bei sehr schwachem UV-Signal durch große aktive Fläche
optimal geeignet für preiswerte Sonnen-UV-Dosimetrie
Lieferfähigkeit ist bis zu 2.000.000 Stück jährlich.
Rev. 1.4
Page 1 [4]
Ultraviolet selective thin film sensor
TW30SX
Features
•
•
•
•
•
•
•
Schottky-type photodiode
Intrinsic visible blindness due to wide-bandgap semiconductor material
Large photoactive area
No focusing lens needed, therefore large usable incident angle
No interference filter required
Designed to operate in photovoltaic mode
TO-18 metal package
Maximum Ratings
Parameter
Symbol
Value
Unit
Operating temperature range
Reverse voltage
Forward current
Total power dissipation at 25°C
T
opt
V
Rmax
I
Fmax
P
tot
-20 ... +80
3
1
1
°C
V
mA
mW
Rev. 1.4
Page 2 [4]
Ultraviolet selective thin film sensor
TW30SX
General Characteristics
(T
a
= 25 °C)
Parameter
Symbol
Value
Unit
Active area
Active area dimensions
Max. viewing angle
Shunt resistance
(dark)
Dark current at
10mV reverse bias
Open circuit voltage
(200µW/cm
2
,
λ=300nm)
Short circuit current
(200µW/cm
2
,
λ=300nm)
Breakdown voltage
(dark)
A
LxW
α
R
s
4,18
2.2 x 1.9
70
300
mm
2
mm
2
degree
MΩ
I
d
30
pA
V
0
>250
mV
I
0
175
nA
V
BR
>3
V
Spectral Characteristics
(T
a
= 25 °C)
Parameter
Symbol
garanteed
Value
Unit
Max. spectral sensitivity
Wavelength of max. spectral sensitivity
Range of spectral sensitivity
(S=0.1*S
max
)
Visible blindness
S
max
λ
Smax
-
21
300
215 – 387
mA W
nm
nm
-1
S
max
S
400nm
50
Rev. 1.4