EEWORLDEEWORLDEEWORLD

Part Number

Search

5900

Description
AC Fans Tubeaxial, 127x38mm 115VAC, Sleeve
CategoryThermal management products    Heat resisting bracing   
File Size127KB,1 Pages
Manufacturerebm-papst
Websitehttp://www.ebmpapst.com
Environmental Compliance
Download Datasheet Parametric View All

5900 Online Shopping

Suppliers Part Number Price MOQ In stock  
5900 - - View Buy Now

5900 Overview

AC Fans Tubeaxial, 127x38mm 115VAC, Sleeve

5900 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Makerebm-papst
Reach Compliance Codecompliant
Factory Lead Time14 weeks
Heat Resistant Support Device TypeAC FAN
Base Number Matches1
Max.
206
m /h
3
AC axial fans
127 x 38 mm
– Material:
Housing: Die-cast aluminum
Impeller: GRP
1)
(PA)
Direction of air flow:
Exhaust over struts
Direction of rotation:
Counterclockwise,
looking towards rotor
Connection:
Via 2 flat plugs 2.8 x 0.8 mm
grounding lug for M4 x 6
Weight:
570 g
– Possible special versions:
(See page 12)
- Moisture protection
1) Fiberglass-reinforced plastic
Power consumption
Sound power level
Temperature range
Nominal voltage
Series 5900
Sound pressure level
Sintec sleeve bearings
Ball bearings
Service life L10
at 40 °C
Nominal speed
Frequency
at T max
Air flow
Air flow
Nominal data
Type
5988
5950
5958
5938
5900
5908
Subject to change
m
3
/h
150
180
180
162
206
206
cfm
88.2
106
106
95.2
121
121
VAC
230
230
230
115
115
115
Hz
50
50
50
60
60
60
dB(A)
37
43
44
40
46
47
Bel(A)
4.9
5.4
5.5
4.9
5.7
5.8
/
Watts
13.0
18.0
18.0
12.0
17.0
17.0
rpm
-1
2 250
2 700
2 750
2 500
3 050
3 100
°C
-30...+55
-20...+50
-30...+60
-30...+55
-20...+55
-30...+75
Hours
Hours
35 000 / 20 000
40 000 / 32 500
40 000 / 25 000
35 000 / 20 000
42 500 / 30 000
42 500 / 20 000
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level L
W
A ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
2016-01
214
Finger guards
from p. 242
Cables
P. 255
Curve
¿
¬
¬
¡

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2926  2307  518  247  1949  59  47  11  5  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号