Option “K” is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between 0.031 and 0.093 inches (0.79 to 2.36 mm), and loads rated up to 50
Amps. For higher load currents, the “K” standoff temperature must not exceed 105°C. For additional application assistance please contact Crydom Technical Support.
(3)
Output will self trigger between 450-600Vpk, Min., not suitable for capacitive loads.
(4)
Instantaneous turn-on version is not recomended for capacitive loads. Use zero turn-on only.
(5)
All parameters at 25°C unless otherwise specified.
(6)
Heat sinking required, see derating curves.
(7)
For 40mA minimum current, the voltage drop increases over maximum rated.
(8)
Maximum turn-on voltage for -B option is: 1VDC for DC control, 10Vrms for AC control, and 4Vrms for E control range.
(9)
For relays with option “G” minimum control voltage is 4.5VDC.
(10)
Must turn-off voltage for -B option is: 3VDC for DC control, 90Vrms for AC control, and 18Vrms for E control range.
(11)
Turn-on time for Instantaneous turn-on versions is 0.02 msec (DC Control Models).
(12)
All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report).
(13)
Load can be wired to either SSR output terminal 1 or 2.
(14)
Elective Input Status LED, “G” option.
(15)
Elective Overvoltage Protection, “P” option.
(16)
Mechanical dimensions vary from G3 models.
For additional information or specific questions, contact Crydom Technical Support.
What should hardware engineers or companies do if they cannot find some components during RD or production?
Especially for some Japanese companies, it is difficult to find agents in China.
So I sugges...
I am now learning 51 single chip microcomputer by myself. Now I have a question to ask you: What is the function of R_XD T_XD P1.0 P1.1 when programming? Thank you very much for your reply;...
I have a GPRS module, connected to the PC's COM1, debugged on the HyperTerminal, OK Now I want to develop an application using GPRS to access the Internet in VS2005, and run it on the WM6 simulator. M...
WARNING: formal port 'clk' of module 'testbench' is not connected in component instance 'testbench'module testbench(clk,Data_in,OUT); output clk,Data_in,OUT; electrical OUT; electrical Data_in; parame...
Servo motors are usually divided into stepper motors, DC brushed servo motors, DC brushless servo motors, and AC servo motors. With the advancement of technology, many special servo motors have emerge...