EEWORLDEEWORLDEEWORLD

Part Number

Search

LSRK028T

Description
Industrial & Electrical Fuses 2.8A 600VAC 300VDC Class RK1
CategoryCircuit protection   
File Size238KB,3 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet Parametric View All

LSRK028T Online Shopping

Suppliers Part Number Price MOQ In stock  
LSRK028T - - View Buy Now

LSRK028T Overview

Industrial & Electrical Fuses 2.8A 600VAC 300VDC Class RK1

LSRK028T Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerLittelfuse
Product CategoryIndustrial & Electrical Fuses
RoHSN
ProductClass RK1 Fuse
Current Rating2.8 A
Voltage Rating AC600 VAC
Fuse TypeTime Delay / Slow Blow
Voltage Rating DC300 VDC
Body StyleCartridge Fuses
Mounting StyleHolder
Termination StyleClip
Fuse Size / GroupPOWR-PRO
Indicator StyleWithout Indicator
PackagingBulk
TypePower Guard
Interrupt Rating200 kA at 600 VAC / 300 kA at 600 VAC / 20 kA at 300 VDC
Factory Pack Quantity1
POWR-PRO
®
Fuses
LLNRK/LLSRK Series POWR-PRO
®
Class RK1 Fuses
250/600 VAC • Dual-Element, Time-Delay • 1/10 – 600 Amperes
Littelfuse LLNRK and LLSRK series POWR-PRO fuses provide superior
overload and short-circuit protection for service entrance, main, feeder
and general-purpose branch circuits up to 600 amperes.
LLNRK/LLSRK series fuses can be installed in existing Class H fuse
blocks to upgrade systems containing lower interrupting rating Class H
one-time or renewable fuses.
POWR-PRO
®
Fuses
Applications
All general purpose circuits
Motors
Transformers
Solenoids
Fluorescent lighting
All system components with high in-rush currents
Features/Benefits
• Extremely current-limiting — Reduces damage to circuits and
equipment under short-circuit conditions. Stops damaging short-
circuits faster than any mechanical protective device.
• 300kA Interrupting Rating — Littelfuse self-certified to 300,000
amperes as standard. Meets future trend towards higher available
short-circuit currents.
• Reduced costs — Current-limiting design often permits use of readily
available, less costly equipment. Low resistance design reduces
power consumption and utility bills.
• Excellent time-delay — True dual-element construction, with separate
non-fatiguing thermally-reversible spring-loaded thermal overload
element, withstands repeated surges within rated time delay without
opening needlessly. Eliminates needless downtime caused by power
surges or equipment demands.
Specifications
Voltage Ratings:
AC: 250 Volts (LLNRK)
600 Volts (LLSRK)
DC: 125 Volts (LLNRK)
300 Volts (LLSRK)
AC: 200,000 amperes rms symmetrical
300,000 amperes rms symmetrical
(Littelfuse self-certified)
DC: 20,000 amperes
1/10 – 600 amperes
AC: Standard 248-12, Class RK1
UL Listed (File No: E81895)
CSA Certified (File No: LR29862)
QPL: Federal Specification No. WF-1814
DC: Littelfuse self-certified
Ampere Ratings
10
1
2
8
10
6
1
4
25
80
1
100
1 ⁄
8
3
7
30
90
2
10
1
1
4
3
2
10
8
35
100
1
4
1
4
*
1 ⁄
10
3 ⁄
2
9
40
110
3
10
1
6
10
4
10
45
125
4
10
1
8
10
4
1
2
12
50
150
1
2
2
5
15
60
175
6
10
2
1
4
5
6
10
17
1
2
70
200
8
10
2
1
2
6
20
75*
225
* LLSRK Only.
Example part number (series & amperage): LLNRK 450.
For online ordering, use numbers LNRK and LSRK for LLNRK/LLSRK.
1
15
Interrupting Ratings:
250
300
350
400
450
500
600
Ampere Range:
Approvals:
Recommended Fuse Blocks
LR250 series (LLNRK Series)
LR600 series (LLSRK Series)
Refer to the Blocks & Holders section of this catalog for additional information.

www.littelfuse.com
© 2005 Littelfuse
POWR-GARD
Products Catalog
Data Sorting
I have a problem, please help me. Every 10 clock cycles, a 24-bit wide number arrives, which needs to be compared with the previous 1024 data, and the largest one is placed in front. In other words, w...
zhoudaoxi FPGA/CPLD
ARM interrupt semaphore problem
When calling assembly from C, you can use __swi(int) to set the semaphore, and the compiler will automatically recognize it. But how do you set the semaphore for an interrupt in assembly? Where is thi...
kiny ARM Technology
A wild idea for the future of energy harvesting: Harvesting the power of tree growth
With the increase of environmental awareness, people have begun to use various natural resources such as solar energy, wind energy, and tidal energy to improve the existing energy system structure in ...
fish001 Energy Infrastructure?
[Theme Month] What is the impact of the DC/DC output resistance of the switching power supply on the fall time?
[Theme Month] What is the impact of the DC/DC output resistance of the switching power supply on the fall time? How to select the output inductor and capacitor?...
打不死xiaoqiang Power technology
How to set ACLK of MSP430G2553? A novice needs guidance
I want to set ACLK to 12kHZ, which registers should I set? ? ?...
13618027298 MCU
RFID Literature: RF rectifier for passive UHF RFID transponders
MOS rectifier, this article proposes an improved version of the diode structure, which actually adds bulk voltage processing, so that the body effect is weakened and the turn-on voltage of the entire ...
七月七日晴 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1238  2015  2116  880  2657  25  41  43  18  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号