EEWORLDEEWORLDEEWORLD

Part Number

Search

TB200-24

Description
Barrier Terminal Blocks BARRIER BLOCK
CategoryThe connector   
File Size62KB,1 Pages
ManufacturerEaton
Environmental Compliance
Download Datasheet Parametric View All

TB200-24 Online Shopping

Suppliers Part Number Price MOQ In stock  
TB200-24 - - View Buy Now

TB200-24 Overview

Barrier Terminal Blocks BARRIER BLOCK

TB200-24 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerEaton
Reach Compliance Codecompliant
ECCN codeEAR99
Factory Lead Time6 weeks 1 day
Other features94V-0, THERMOPLASTIC
Fastening methodSCREW
Installation typeCABLE
Number of layers1
Rows2
Number of channels48
Rated current30 A
Rated voltage300 V
safety certificateUL; CSA; CE; IEC
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge8 AWG
MAGNUM
®
Top & Bottom Marking Strips
Double Row Terminal Blocks (TB100, TB200, TB300, TB345 SERIES)
Single & Double Row
Filtered Connectors
TOP MARKER STRIPS
Top mounting marker strips are available in white (opaque)
plastic. Two cover clips are supplied with each marker
strip.
All top marker strips must be ordered separately. Consult
factory for special legends.
Example: 12 position cover, TB200, .032” x .312”, with no
legends . . . Part No. is X20312.
Example: 12 position cover, TB200HB, .060” x .500”, with
no legends . . . Part No. is X23312HB.
Euro-MAG Series
PCB – Spring Clamp
Part Numbering System
Series
Top Marker Strip
Poles
X
133
- TB100 (.060 thk x .500w)
103
- TB100 (.032 thk x .312w)
233
- TB200 (.060 thk x .500w)
233TB
- TB200HB (.060 thk x .500w)
203
- TB200 (.032 thk x .312w)
203HB
- TB200HB (.032 thk x .312w)
333
- TB300 & TB345 (.060 thk x .500w)
303
- TB300 & TB345 (.032 thk x .380w)
02
to
36
(TB100)
02
to
30
(TB200/TB200HB)
02
to
24
(TB300/TB345)
Note: Marking Strips are not available on
TB400 Series.
Base & Rail Mount
Connectors
BOTTOM MARKER STRIPS;
Bottom mounting marker strips are made of black PVC,
.030” thick. Space is available to handle most marking sit-
uations. All marker strips must be ordered separately.
To order, specify part number, required legends and (BF)
bottom forward, (BR) bottom reverse, (TF) top forward, or
(TR) top reverse. Consult factory for specials.
Space for marking
one side
Space for marking
two sides
Power Distribution Blocks
Example: 13 position strip, TB100 with no legends, space
for marking one side . . . Part No. is X10513.
Position for legends (one side, two sides) can be specified
standard. Standard legend height is .125”. Standard leg-
ends are 0-99 and A-Z. Special legends are available on
special order. Drawing(s) must be submitted to ensure
accuracy of part required.
TB100
Dim. A
Dim. B
1.13”
1.38”
TB200
1.37”
1.62”
TB200HB
1.62”
1.81”
TB300
1.58”
1.81”
TB345
1.58”
1.81”
TB400
N/A
N/A
Part Numbering System
Series
Bottom Marker Strip
Poles
Orientation
WIRE MANAGEMENT PRODUCTS
X
105
101
205
201
295
291
305
301
-
-
-
-
-
-
-
-
TB100 – marking one side
TB100 – marking both sides
TB200 – marking one side
TB200 – marking both sides
TB200HB – marking one side
TB200HB – marking both sides
TB300 & TB345 – marking one side
TB300 & TB345 – marking both sides
02
to
36
(TB100)
02
to
30
(TB200/TB200HB)
02
to
24
(TB300/TB345)
BF
– bottom forward
BR
– bottom reverse
TF
– top forward
TR
– top reverse
Note: Marking Strips are not available on TB400 Series.
36
Personnel positioning system base station
[align=left][b]System Introduction[/b][/align][align=left] This system adopts the international standard ZigBee wireless communication technology, integrating personnel positioning, attendance managem...
lwslxh RF/Wirelessly
How can I reverse the PWM signal and then give it to the MOS tube?
[i=s]This post was last edited by wolfcan on 2016-9-21 20:57[/i] Hello experts, I am working on control algorithms, but I need to make a hardware circuit for experiments. Now I have a question for you...
wolfcan Power technology
485 Communication Problem
The 485 protocol format is generally used for large-scale communication of single-chip microcomputers. I checked the information of 485 IC 65HVN3082, which says "1/8 load--the bus can connect up to 25...
eeleader Industrial Control Electronics
I have read a lot of explanations of the startup code but still don't understand it
How is the memory initialized in the startup code? How is the stack initialized? How is it implemented? What is the result of the implementation? I have read many explanations of the startup code but ...
xinbako stm32/stm8
[TI recommended course] #Live replay: TI mmWave millimeter wave radar application in automobiles#
//training.eeworld.com.cn/TI/show/course/5657...
SensorYoung TI Technology Forum
JPEG
When I use jpeg to decode .jpg images, jpeg_read_scanlines can only read the information of each line, so the decoding is very slow. Is there any way to increase the decoding speed?...
xieyuanbin Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1667  2256  107  1891  1679  34  46  3  39  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号