The Bel Power Solutions MAP30/40/42 Series of power supplies
combines low cost and universal input in a board-only power solution
to meet commercial and industrial requirements. Full international
safety, EMI and ESD compliance ensure worldwide acceptance.
All units bear the CE Mark.
Fixed frequency operation simplifies system level operation. The
MAP30/40/42 Series is configured to the international standard 3 x 5
inch footprint. Input and output connections are made via popular
single-row Molex connectors. Single output models feature wide-
range output adjustability to meet a wide variety of standard and user-
specific output voltage requirements.
Universal Input 85-264 VAC
Input Transient & ESD Compliance to EN61000-4-2/-3/-4
Meets EN55022 Conducted and Radiated Limits
Greater than 311,000 Hours MTBF
Remote Sense (MAP30, MAP42)
RoHS Compliant
CE Marked to Low Voltage Directive
2
MAP30/40/42 Series
MODEL
9
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAX OUTPUT
CURRENT
PEAK
OUTPUT
CURRENT
1
LINE
REGULATION
LOAD
REGULATION
RIPPLE &
NOISE
2
INITIAL SETTING
ACCURACY
MAP30-1005G
MAP42-1005
MAP42-1012G
MAP42-1024G
5V
5V
12V/15V
24V/28V
4.7V to 5.8V
4.7V to 5.8V
11V to 18V
23V to 29V
6A
8A
3.4/2.7A
3
1.7/1.4A
3
8A
8
11A
4.6/3.7A
3
2.3/1.9A
3
0.2%
0.2%
0.2%
0.2%
±1%
±1%
1%
1%
1%
1%
1%
1%
4.9V to 5.1V
4.9V to 5.1V
11.9V to 12.1V
23.8V to 24.2V
MODEL
9
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT
PEAK
OUTPUT
CURRENT
4
LINE
REGULATION
LOAD
REGULATION
RIPPLE &
NOISE
2
INITIAL SETTING
ACCURACY
MAXIMUM
OUTPUT
POWER
+5V
MAP40-3000G
+12V
-12V
+5V
MAP40-3100G
+12V
-12V
+5V
MAP40-3101G
+24V
-12V
+5V
MAP40-3105G
+12V
-5V
+5V
MAP40-3500G
+12V
-12V
+5V
MAP40-3003G
+15V
-15V
4.7V to 5.5V
Fixed
Fixed
4.75V to
5.25V
Fixed
Fixed
4.75V to
5.25V
Fixed
Fixed
4.7V to 5.8V
Fixed
Fixed
4.7V to 5.8V
Fixed
Fixed
4.7V to 5.8V
Fixed
Fixed
3A
2A
0.3A
3A
2A
0.3A
3A
1A
0.3A
3A
2A
0.5A
5A
1A
0.3A
3A
1.5A
0.2A
5A
3.5A
0.5A
5A
3.5A
0.5A
5A
1.5A
0.5A
5A
3.5A
1A
6A
3.5A
0.5A
5A
3A
0.5A
0.2%
1%
1%
0.2%
1%
1%
0.2%
1%
1%
0.2%
1%
1%
0.2%
1%
1%
0.2%
1%
1%
2%
3.5%
5
2%
6
2%
3.5%
5
2%
2%
3.5%
5
2%
2%
3.5%
5
2%
2%
3.5%
5
2%
2%
3.5%
5
2%
6
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
4.9V to 5.1V
11.5V to 12.5V
-11.5V to -12.5V
4.9V to 5.1V
11.5V to 12.5V
-11.4V to -12.6V
4.9V to 5.1V
23.0V to 25.0V
-11.5V to -12.5V
4.9V to 5.1V
11.5V to 12.5V
-4.75V to -5.25V
4.9V to 5.1V
11.5V to 12.5V
-11.4V to -12.6V
4.9V to 5.1V
14.7V to 15.3V
-14.3V to -15.7V
40 W
7
40 W
7
40 W
7
40 W
7
40 W
7
40 W
7
1
2
Peak ratings may be used as maximum output current with 100 Linear Feet per Minute (LFM) forced air cooling.
Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3
MAP42-1012G output currents are expressed as 12V/15V operation. MAP42-1024G output currents are expressed as 24V/28V operation.
4
Peak loads for 30 seconds or less are acceptable, (10% duty cycle max.).
5
Quasi regulated output. See Regulation Curves for more information.
6
Requires a minimum load of 0.5A on V1 or 0.3A on V2.
7
Needs 170 LFM forced air cooling for use at 50°C ambient.
8
Needs 200 LFM forced air cooling for use at 50°C ambient.
9
Non-G models use lead solder exemption and are not recommended for new designs.
Xxx
Model highlighted in yellow is not recommended for new designs.
tech.support@psbel.com
MAP30/40/42 Series
PARAMETER
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
3
CONDITIONS / DESCRIPTION
Continuous input range
AC input
Lowest AC input voltage that regulation is maintained with full rated
loads.
Nominal AC Input Voltage (115VAC), full rated load.
90 VAC (40W load).
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor, Vin = 264 VAC (one cycle), 25° C
Switching frequency of power supply (fixed frequency).
MAP42
MAP30, MAP40
MIN
85
90
47
85
15
NOM
MAX
264
264
63
UNITS
VAC
Hz
VAC
ms
1.2
A
RMS
38
23
25
30
A
PK
kHz
PARAMETER
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
CONDITIONS / DESCRIPTION
Full load @120 VAC
Single output models; MAP30, MAP42.
All multiple output models, see regulation graphs.
Full load, 20 MHz bandwidth.
Multiple output models with convection cooling.
Output voltage overshoot/undershoot at turn-on, V1.
Varies by output, total regulation includes: Line changes from 90-
132 VAC or 175-264, changes in load starting at 20% load and
changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output only of multiple
output units).
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
MIN
NOM
MAX
UNITS
70% typical
0.0
See Model Selection Chart.
40
1
See regulation graphs.
Watts
%
Amps
Transient Response
Turn-on Delay
Turn-on Rise Time
500
1
20
2
μs
Sec
ms
PARAMETER
Overvoltage Protection
CONDITIONS / DESCRIPTION
MAP30-1005G, MAP42-1005
MAP42-1012G
MAP42-1024G
Main output only of multiple output units.
Fully protected against output overload and short circuit. Automatic
recovery upon removal of overload condition.
Total cable drop, single output models only.
MIN
5.8
20.0
32.0
5.8
NOM
MAX
6.8
22.0
37.0
6.8
UNITS
V
Overload Protection
Remote Sense
8
130
250
%
mV
Power Fail Warning is not available for MAP80-1024G. The MAP80-1012G is an open collector output, capable of sinking 35 mA, maximum.
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
BCD.00563_AC
© 2016 Bel Power Solutions & Protection
4
MAP30/40/42 Series
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
PARAMETER
Agency Approvals
Approved to the latest edition of the following standards;
UL/CSA60950-1 2
nd
, IEC60950-1 2
nd
and EN60950-1 2
nd
.
Input to Chassis
Dielectric Withstand Voltage
Input to Output (tested by manufacturer only)
FCC CFR title 47 part 15 sub-part B - conducted
Electromagnetic
EN55022 / CISPR 22 conducted (Note 1)
Interference
EN55022 / CISPR 22 radiated (Note 2)
Line to Line
Input Transient Protection
EN61000-4-5 Level 3
Line to Ground
Insulation Resistance
Input to output
MAP42,
MAP40-3100G/3001G/3105G/3500G
MAP30-1005G,
MAP40-3000G, MAP40-3003G
2121
4242
B
B
B
1
2
7
500
VDC
Class
kV
MΩ
Leakage Current
Per EN60950, 264VAC
μA
750
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
CONDITIONS/DESCRIPTION
Operating
Non-operating
Derate linearly above 50°C by 2.5% per °C
to a maximum temperature of 70°C
MIN
NOM
MAX
10k
40k
50
70
85
UNITS
ASL Ft.
°C
°C
%/°C
%RH
G
G
RMS
At 100% load:
At 50% load:
0
0
-40
0°C to 70°C (after 15 minute warm-up)
Non-condensing
Operating, peak acceleration
Random vibration, 10Hz to 2kHz, 3 axis
5
±0.02
±0.03
95
20
6
14.25
13.75
13.25
12.75
+5 @ 5.0 Amps
V
12.25
+5 @ 3.0 Amps
V
+5 @ 1.0 Amps
V
+5 @ 0 Amps
V
11.25
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
11.75
12V OUTPUT CURRENT
Figure1. MAP40-3500G Typical Quasi Regulation Performance For +12V Output
tech.support@psbel.com
MAP30/40/42 Series
13.5
5
13.0
12.5
12.0
+5V @ 3.0 Amps
11.5
+5V @ 1.8 Amps
+5V @ 0.6 Amps
+5V @ 0 Amps
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
11.0
12V OUTPUT CURRENT
Figure 2. MAP40-3000/3100/3105G Typical Quasi Regulation Performance For +12V Output
17.0
16.5
16.0
15.5
15.0
14.5
14.0
13.5
0
0.15
0.3
0.45
0.6
0.75
0.9
1.05
1.2
1.35
1.5
+5V @ 3.0 Amps
+5V @ 1.8 Amps
+5V @ 0.6 Amps
+5V @ 0 Amps
15V OUTPUT CURRENT
Figure 3. MAP40-3003G Typical Quasi Regulation Performance For +15V Output
J1
NEUTRAL
PIN 1
MAP30 J2
PIN 7
N/C
V1
V1
GND
GND
+Sense
-Sense
MAP40 J2
PIN 6
V2
V1
V1
GND
GND
V3
MAP42 J2
PIN 6
V1
V1
GND
GND
+Sense
-Sense
LINE
PIN 2
J3
SAFETY EARTH GROUND
(0.250" x 0.032" FASTON)
PIN 1
PIN 1
PIN 1
J1/J2 MATES WITH MOLEX (SERIES 2139 or SERIES 41695) .156" (4mm)
CENTER CRIMP TERMINAL HOUSING OR EQUIVALENT
Figure 4. Electrical Connectors
PARAMETER
Dimensions
Weight
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
mm
in
kg
lb
127.0 x 76.2 x see table below
5.0 x 3.0 x see table below
0.26
0.6
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
BCD.00563_AC