EEWORLDEEWORLDEEWORLD

Part Number

Search

CECC16101-007-01-07-04-05P

Description
Power/Signal Relay,
Categoryrelay   
File Size417KB,5 Pages
ManufacturerHi-G Relays
Download Datasheet Parametric View All

CECC16101-007-01-07-04-05P Overview

Power/Signal Relay,

CECC16101-007-01-07-04-05P Parametric

Parameter NameAttribute value
MakerHi-G Relays
Reach Compliance Codeunknown
ECCN codeEAR99
Manufacturer's serial number2K-6600
Relay typePOWER/SIGNAL RELAY
Base Number Matches1
HALF SIZE CRYSTAL CAN RELAY
Series
2 AMPERE DPDT
2K-6600
Product Description
A complete series of half crystal can hermetically sealed relays manufactured and qualified to the referenced CECC specifications. The
leading relay design in military and commercial application is represented in Hi-G 2K-6600 series relay. The product advanced design
provides superior performance in the environmental and operational requirements of today’s sophisticated equipment. Volume
production coupled with continuing qualification programs, ensure product consistency and the highest degree of reliability.
The following construction features ensure the highest reliability in extreme environments:
-
All welded relay construction
-
Cleaning and sealing techniques ensures maximum internal cleanliness
-
Low level to 2 amperes switching
-
2 form C, DPDT contacts, special metal alloy with gold plating
-
Frame, armature designs and force / mass ratio provides exceptional immunity to shock and vibration.
Series Type
-
2K-6600
2 form C, DPDT
Code
01
02
Contact Category
Light Duty Contact
0,01 mA, 5 Vdc max.
0,01 mA, 0,01 Vdc max.
Types
007, 014, 021
021
CECC 16101 – 007
16101 – 014
16101 – 021
(SEE NOTE *)
Environmental and Physical Specifications
Temperature (Ambient)
Shock
Vibration (sinusoidal)
Bump
Sealing
Weight
Finish
- 65°C to + 125°C
50 g, 11 ms., half sine wave
20 g, 10 to 2000 Hz, 1,5 amplitude peak
40 g, 6 ms.
All welded, Hermetic
0,46 oz. (13,0 grams) max.
Bright tin lead plated terminals and case
* NOTE:
- 007
- 014
- 021
ITALIAN FACTORY SPECIFICATION
GERMAN / FRENCH FACTORY SPECIFICATION
UK FACTORY SPECIFICATION
A part from the range and a few environmental tests, all specs. are identical.
Nuova Hi-G is the only company qualified to each / all country specs.
Electrical Characteristics
(over the Temperature range. Unless otherwise noted)
Coil Data
Contact Rating
(Note: All ratings with grounded
case)
See Typical Characteristics chart
Type Load
Contact Load
Low Level
10 mA / 30 mV
Resistive
2 A / 28 Vdc
Overload
4 A / 28 Vdc
Inductive
0,75 A / 28 Vdc (200 mH)
0,05
max. initial, 0,2
max. after life
Cycles min.
1.000.000
100.000
100
100.000
Contact Resistance
Operate Time
Release Time
Contact Bounce
Dielectric Strength
Insulation Resistance
Intercontact Capacitance
Sensitivity
4,0 ms. max. at 25°C
4,0 ms. max. at 25°C
2,5 ms. max. at 25°C. Series: 007, 014
3,0 msec. max. at 25°C. Series: 021
500 Vrms min., 60 Hz, all points, at sea level
1.000 M min. all points at 500 Vdc
2,5 pF typical
250 mW at pick-up, 1,0 W max., at nominal rated coil voltage, at 25 °C
High Generation S.r.l.
Tel: + 39 06 96873136
Fax: + 39 06 94443060
37
REV. 0/2012
Unboxing - ESP32-S2 and ESP32-S3 Development Boards + Modules
[i=s]This post was last edited by mars4zhu on 2022-7-16 18:50[/i]Dear friends who participated in the event, have you considered the risk of the new coronavirus when you received packages from DigiKey...
mars4zhu DigiKey Technology Zone
LM3S818 interrupt trigger setting
The interrupt has a trigger depth setting, which is very efficient when transmitting large amounts of data. In use, it is found that its depth detection mechanism is similar to the low-level detection...
淮海的大学 Microcontroller MCU
Principle of Magnetic Latching Relay
[font=仿宋_GB2312][size=4]The magnetic latching relay is attracted after the excitation coil is energized (DC). After the excitation coil is de-energized, it remains attracted due to the residual magnet...
lzcqust Power technology
Is children's programming a waste of money?
In shopping malls, you can often see people promoting children's programming. These salespeople will imply that children's programming is a skill that every child must master nowadays, making parents ...
eric_wang Robotics Development
Questions about VxWorks virtual network card
I wrote a virtual network card, and used FPGA to allocate memory pool. I can view the virtual network card device through ifShow() and muxShow(). In addition, there is a real network card device. Howe...
pengdingbo Real-time operating system RTOS
Robotics
In the 1950s, industrial robots came into being to replace manual labor in monotonous, repetitive physical labor or dangerous work and improve product quality. Since then, robots, as a typical represe...
songrisi Robotics Development

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 997  396  230  1635  2502  21  8  5  33  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号