EF12.A04BK190C0.1210.019

Description
Mains Power Connector,
CategoryThe connector    The connector   
File Size1MB,6 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

EF12.A04BK190C0.1210.019 Overview

Mains Power Connector,

EF12.A04BK190C0.1210.019 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact materialNOT SPECIFIED
JESD-609 codee3/e2
Base Number Matches1
Power Entry Modules with Line Filter
www.schurter.com/pg06
IEC Appliance Inlet C20 with Filter, Circuit Breaker TA45 (recessed)
EF2
Standard- or Medical-Filter
C20
70° C
Description
- Panel Mount:
Screw-on mounting from front side
- 3 Functions:
Appliance Inlet Protection class I, circuit breaker type TA45 2-
pole, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
Characteristics
Approvals
- All single elements are already wired
- Line switch non-illuminated
Illuminated version on request
Thermal overload protection
Optional with undervoltage- or remote trip release
- With EMC-shield
- Qualified for use in equipment according IEC/EN 60950
- VDE Certificate Number: 40001520
- UL File Number: E72928
Other versions on request
References
Weblinks
- Variant with notch for V-Lock mating Cordsets
Alternative: version without line filter EF11
Alternative: Standard version
pdf-datasheet, html-datasheet, General Product Information, Approvals,
RoHS, CHINA-RoHS, Mating Connectors, e-Shop, SCHURTER-Stock-
Check, Distributor-Stock-Check, CAD-Drawings, Accessories, Detailed
request for product
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
12 - 16 A @ Ta 40 °C / 250 VAC; 50 Hz
12 - 20 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C20 acc. to
IEC/EN 60320-2-2 UL 498, CSA C22.2
no. 42 (for cold conditions) pin-tempera-
ture 70 °C, 16 A, Protection Class I
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Rocker switch 2-pole, non-illuminated
or illuminated, acc. to IEC 61058-1
Technical Details
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical Details
> 100'000 h acc. to MIL-HB-217 F
Circuit Breakers
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Line Switch
Line Filter
MTBF
EMC Products

Free wifi
If it's simple, use connectify software. If it's complicated, use: 1. Run the command prompt as an administrator (use the shortcut key WIN+R to call up the run and then enter CMD to open the command p...
chenhao520 Creative Market
Verilog program for DS1302 chip
Hey guys, I would like to ask how to write the timing of the CE and SCLK clocks of the DS1302 chip. The data of the DS1302 chip states that CE must be high when writing command data and register data,...
sun139 Embedded System
New book recommendation: Programming with MicroPython
[i=s]This post was last edited by lcofjp on 2017-10-10 12:48[/i] I don't know MicroPython, but I think this book is good. I saw some familiar boards. Table of contents screenshot:Download address: [ur...
lcofjp MicroPython Open Source section
MPS Mall Big Offer Experience Season】 Unboxing
While browsing EE, I happened to find that eeworld and MPS had cooperated to launch a welfare event, so I decided to participate. [Full cashback for orders, capped at 300 yuan] MPS Mall Power Design G...
sylar^z Power technology
Power supply capacitor selection
What is the relationship between the input and output capacitors of the voltage regulator and the actual circuit selection?...
gongjl Power technology
HOHO, our 51DIY——LC measurement tool is completed!
[media=ra,400,300,0][/media] Comrades, I am happy to tell you that I have finished this week's regular post!!Before I post the picture, let me first reveal a little embarrassing thing: I have doubted ...
辛昕 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2857  622  507  816  613  58  13  11  17  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号