EEWORLDEEWORLDEEWORLD

Part Number

Search

657H/2G-3V

Description
Toggle Switch, 3PDT, Momentary, 5A, 25VDC, Solder Terminal, Lever Actuator, Panel Mount
Categoryswitch    Toggle switch   
File Size315KB,8 Pages
ManufacturerAPEM
Environmental Compliance  
Download Datasheet Parametric View All

657H/2G-3V Overview

Toggle Switch, 3PDT, Momentary, 5A, 25VDC, Solder Terminal, Lever Actuator, Panel Mount

657H/2G-3V Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerAPEM
Reach Compliance Codecompliant
ECCN codeEAR99
Is SamacsysN
Actuator typeLEVER
body width31.8 mm
body height24 mm
Body length or diameter34.5 mm
Contact (AC) maximum rated R load15A@125VAC
Maximum contact current (AC)15 A
Maximum contact current (DC)5 A
Contact (DC) maximum rated R load5A@25VDC
Maximum contact voltage (AC)125 V
Maximum contact voltage (DC)25 V
Electrical life10000 Cycle(s)
JESD-609 codee4
Manufacturer's serial number600
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
method of packingBULK
surface mountNO
Switch actionMOMENTARY
switch function3PDT
Switch typeTOGGLE SWITCH
Terminal surfaceSilver (Ag)
Termination typeSOLDER
Base Number Matches1
600H and 600NH series
Toggle switches - high amperage
Distinctive features and specifications
Construction
Terminal and contact support are manufactured from a single piece of metal. The
contacts are resistance-welded to the terminal for increased mechanical strength.
Rating
A
These switches are suitable for motor loads and power applications up to
15A 250VAC or 10A 400VAC
Metal or insulated lever
UL, CSA and NF-VDE (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage ratings : see tables below
• Peak current : 30A max. during 1/2 sine, 250VAC
• Initial contact resistance : 10 mΩ max. at 1A 2VDC
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength :
2.000 Vrms 50 Hz min. between terminals
2.500 Vrms 50 Hz min. between terminals and frame
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
600H - 600NH
MODELS
FUNCTIONS
UL
UL 1054
Models for peak currents
Models 600SH and 600SNH with silver
cadmium oxide contacts are
discontinued.
They will be replaced by switches with silver
tin oxide contacts.
- FOR INFORMATION-
Max. current/voltage rating w. resistive load
Functions
ON - OFF
ON - ON
ON OFF ON
Ratings
Electrical life
CSA
CSA 22-2
NF-VDE
EN 61058-1
ON - OFF (1)
Single and
double pole
ON - ON (6)
Other
(4-7-8-9)
ON - OFF (1)
& ON - ON (6)
15A 1/2 HP
125-250VAC
10A 1/2 HP
125-250VAC
15A 1/2 HP
125-250VAC
10A 1/2 HP
125-250VAC
10(4)A
400VAC
T 85/55 (600H)
T 125/55
(600NH)
15A 250VAC
10A 24VDC 10.000 cycles
15A 12VDC
15A 250VAC
6.000 cycles
Other
15A 125VAC
12A 250VAC 10.000 cycles
5A 25VDC
Three pole
Other
(4-7-8-9)
MATERIALS
GENERAL SPECIFICATIONS
• Case : polyester UL94-V0
• Actuator :
- 600H : brass, nickel plated
- 600NH : black polyamide
• Bushing : brass, nickel plated
• Contacts : silver/nickel alloy
• Torque : 1,50 Nm (1.10 Ft.lb) max. applied to nut
• Panel thickness : 4,5 mm (.177) max. between 2 nuts
• Operating temperature : -20°C to +55°C
A-100
www.apem.com
APEM
LM3S8962 I2C bus part learning sharing
Internal I2C bus module introduction: The Inter-Integrated Circuit (I2C) bus provides bidirectional data transmission by adopting a two-wire design (serial data line SDA and serial clock line SCL), an...
eeleader Microcontroller MCU
Technical support issues for group-purchased Mini2440
Haha, let me emphasize here that I hope friends who participate in group buying can find solutions more quickly: 1) If a problem occurs, contact friendly technical support as soon as possible. I have ...
soso Embedded System
My first car
Let me show you my first car. The problem is that I didn’t leave a good space for the LCD, so I had to put it on the system board of the microcontroller, and it was shaking....
xiaotian105 51mcu
How to choose the installation height of Doppler flowmeter sensor?
When installing the Doppler flowmeter, the sensor should be installed as close to the bottom of the channel as possible. If there are a lot of sediments, silt, water plants or stones rolling on the bo...
ywj5188 Industrial Control Electronics
Has anyone tried running MPY in C?
I saw someone run C with subprocess under MPY, and I want to ask if anyone has tried it. I was given a post by a foreigner, but I don’t understand it at my level. [url]https://github.com/PyConPL/Book/...
凉冰 MicroPython Open Source section
There is no signal at all when using the ceramic antenna on the cc2541. Can anyone help me see if that is wrong?
I tried to draw the board myself. The ceramic antenna I used was RFANT3216120A5T, and I drew it according to the data sheet. First, the balun outputted a 50Ω impedance, and then the antenna. But the r...
osiris00 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1014  508  2535  2656  183  21  11  52  54  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号