8345-B03A-T3M2-DB1B1C-50A Overview

CIRCUIT BREAKER HYDRAULIC MAGN

8345-B03A-T3M2-DB1B1C-50A Parametric

Parameter NameAttribute value
Circuit breaker typeMagnetic (hydraulic delay)
Rated current50A
Rated voltage - AC480V
Rated voltage - DC80V
Number of poles3
Actuator typepress slice
illuminationnone
Lighting voltage (nominal)-
Installation typePanel mounting
Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-...
Description
Single or multipole hydraulic-magnetic circuit breakers with trip-free-
mechanism and toggle actuation. A choice of switching characteristics
ensures suitability for a wide range of applications. Industry standard
dimensions and panel mounting. Auxiliary contacts optional. Low
temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934) S-type HM CBE.
Typical applications
In the business fields Communication and Transport: power supplies,
switchgear, instrumentation and process control engineering.
8345
1-pole
2-pole
Standard current ratings and typical internal resistance values
Current
rating (A)
0.05
0.1
1
2
3
5
10
15
20
25
30
40
50
60
80
100
125
Trip curves and internal resistance (Ω) per pole
K1, M1, T1,
K2, M2, T2
452
376
100
0.95
0.26
0.10
0.042
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
<
<
<
<
<
<
0.01
0.01
0.01
0.01
0.01
0.01
94
0.90
0.20
0.10
0.040
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
<
<
<
<
<
<
0.01
0.01
0.01
0.01
0.01
0.01
Technical data
Voltage rating
Current rating range
3 AC 415 V; AC 277/480 V;
AC 120/240 V; AC 240 V; DC 80 V,
0.05...125 A single and multipole
150...180 A single pole, two poles
connected in parallel
higher ratings upon request
AC 240 V 6 A; DC 28 V 3 A
DC 65 V 1 A; DC 80 V 0.5 A
10,000 operations at 1 x I
N
-40...+85 °C (-40...+185 °F)
2.5 kV/2
reinforced insulation in operating area
test voltage
AC 3,000 V
AC 1,500 V
AC 3,000 V
AC 1,500 V
> 100 MΩ (DC 500 V)
operating area IP40
terminal area IP00
10 g (57-2000 Hz) ±0,76mm (10-57Hz)
at 0.9 I
N
10 g at 1 x I
N
10 g at 0.8 x I
N
in all planes.
(57-2000 Hz) ±0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
100 g (11 ms) at 1 x I
N
,
100 g (11 ms) at 0.8 x I
N
,
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
96 hours at 5% salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-3, test Ca
approx. 90 - 120 g per pole
depending on version
3
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664)
Dielectric strength
operating area
pole to pole
main to auxiliary circuit
switching to trip circuit
Insulation resistance
Degree of protection
(IEC 60529)
Vibration
with toggle down:
directions 1, 2, 3, 4, 5:
with curves F1, F2:
Interrupting capacity
to EN 60934, UL 489 and UL 1077
IEC 60934 – test series E
voltage
number of poles
DC 80 V
1+2
AC 240/415 V
1-6
AC 240 V
1
UL 489 – test sequence Z
voltage
number of poles
DC 80 V
1+2
AC 120 V
1
AC 120/240 V
1
AC 240 V
1 (2)
UL 1077
voltage
number of poles
DC 80 V
1+2
AC 277/480 V
1-6
I
N
max. (A)
0.02...125
0.02...80
0.02...20
I
cn
(A)
10,000
6 x I
N
5,000
Shock
directions 1, 2, 3, 4, 5:
direction 6:
with curves F1, F2:
Corrosion
Humidity
Mass
I
N
max. (A)
0.5...125
0.5...80
0.5...80
0.5...20
I
cn
(A)
10,000
5,000
5,000
5,000
Approvals
VDE (EN 60934)
UL 489
UL 1077
CCC
1- to 6-pole
1- to 6-pole
1- to 4-pole
I
N
max. (A)
0.02...125
0.02...70
I
cn
(A)
10,000
5,000
06/07
(101106)
www.e-t-a.com
3
- 27
How to correctly set AD via cover oil in batches?
1. First select a representative via and double-click the via (via)2. Left-click to select the via (via), then right-click Find Simillar Objects to find similar objects as shown below:3. Note that the...
dengguoqiang PCB Design
Report on the 8th China International Defense Electronics Exhibition
Brother Niu went to the Beijing Exhibition Hall to attend the 8th China International Defense Electronics Exhibition on May 10. There were many SSD suppliers, connector manufacturers, RF chip supplier...
jameswangsynnex Automotive Electronics
A good collection of analog circuit information - worth collecting
An amplifier is a three-terminal circuit, one of which must be the common "ground" terminal for input and output. If this common "ground" terminal is connected to the emitter, it is called a common-em...
qwqwqw2088 Power technology
I have received the group-purchased industrial analog device set, and I would like to post this to express my gratitude!
[i=s] This post was last edited by dontium on 2015-1-23 13:17 [/i] Good, but unfortunately REF5025 is a standard version, the package is relatively small...
fffofo Analogue and Mixed Signal
Seeking advice from experts--Design of wireless answering system
Topic requirements: Goods are stored in a warehouse. Since the specifications of the goods are not easy to distinguish, it is inconvenient to find them. Now we need to design an electronic automatic t...
广播人 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2249  2523  146  1199  267  46  51  3  25  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号