tfs70H12A.doc
Version 1.0
25.07.2000
VI TELEFILTER
Filter Specification
TFS 70H12A - 1/4
1. Measurement condition
Ambient temperature T
A
:
Input power level:
Terminating impedances in fc:
25
°C.
0
dBm.
for input:
for output:
50
Ω
0 pF.
50
Ω
0 pF.
2. Characteristics
Remark:
Reference level for the relative attenuation
arel
of the
TFS 70H12A
is the minimum of the pass band attenuation
amin.
The minimum of the pass
band attenuation
amin
is defined as the insertion loss
ae
. The reference frequence
fc
is the arithmetic mean value of the upper and lower
frequencies at the
20 dB
filter attenuation level relative to the insertion loss
ae.
The temperature coefficient of frequency
Tc
f
is valid both for the
reference frequency
fc
and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating
temperature range is not included in the production tolerance scheme.
Data
Insertion loss
(Reference level)
Centre frequency
Pass band ( PB ) :
Amplitude ripple in :
Bandwidth ( BW ) :
0,8
3
20
40
50
dB - band width
dB - band width
dB - band width
dB - band width
dB - band width
arel
fc
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
.....
.....
.....
.....
.....
.....
.....
.....
.....
fc
fc
fc
fc
fc
fc
fc
fc
fc
±
±
±
±
-
+
+
+
+
3,6
4,0
5,05
50
50
90
145
155
210
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
fc - 3,6 MHz ... fc + 3,6 MHz
ae
typ. value
21 dB
70,0 MHz
tolerance / limit
max.
23 dB
MHz
fc
at ambient temperature
(f
CTA
)
70 ± 0,08
fc - 4,0 MHz ... fc + 4,0 MHz
0,4 dB
max. 0,8 dB
at ambient temperature T
A
7,45
8,05
9,26
9,88
10,11
MHz
MHz
MHz
MHz
MHz
min.
min.
7,2 MHz
8,0 MHz
max. 10,0 MHz
Relative attenuation
fc
fc
fc
fc
fc
fc
fc
fc
±
±
±
-
+
+
+
+
3,6
5,0
5,05
68
50
90
145
155
45
55...60
45...50
45...55
55...58
25
55...60
-
-
dB
dB
dB
dB
dB
dB
dB
max. 0,8 dB
max.
3 dB
min. 40 dB
min. 45 dB
Group delay ( mean value in PB ):
Group delay ripple in PB (p-p):
Deviation from linear phase in PB :
Triple transit attenuation compared to main signal
Crosstalk
Temperature coefficient of frequency ( Tc
f
) :
Frequency deviation of fc over temperature :
Operating temperature range
Storage temperature range
2,43 µs
70...80 ns
3,3 ° (r.m.s. 0,8 °)
50...52 dB
70...75 dB
max. 2,5 µs
max. 100 ns
max. 4 °
-87 ppm/K²
∆f
c(Hz) = Tc
f
(ppm/K) x (T - T
o
) x f
CTA
(MHz)
- 25 °C ... + 80 °C
- 40 °C ... + 85 °C
Generated:
Wadim Dunzow
Checked/Approved:
Dr. Bert Wall
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
tfs70H12A.doc
Version 1.0
25.07.2000
VI TELEFILTER
3. Package :
22,5 Max.
5,0 max.
Filter Specification
TFS 70H12A - 2/4
13 max.
5,6 max.
2,54 ± 0,2
6x2,54 = 15,62
0,45 Dia.
7,62
TFS 70H12A
tft M25
1
2
7
Date-code:
K
L
M
.......
Year+week
1998
1999
2000
.......
Pin
14
Pin 1
Pin
8
Pin 7
Pin 2, 9
Input
Input RF Return
Output
Output RF Return
Package Ground
14
9
8
4. 50
Ω
matching network:
14
9
8
1
2
7
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
tfs70H12A.doc
Version 1.0
25.07.2000
VI TELEFILTER
5. Air reflow temperature conditions
Filter Specification
TFS 70H12A - 3/4
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Air reflow profile
260
240
220
200
180
temperature / °C
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
time / sec.
140
160
180
200
220
240
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
tfs70H12A.doc
Version 1.0
25.07.2000
VI TELEFILTER
History
Version
1.0
Reason of changes
Filter Specification
TFS 70H12A - 4/4
Name
Dunzow W.
Date
25.07.2000.
Generate
Filter Specification
.
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information