tfs433r.doc
version 3.1
24.05.2002
VI
TELEFILTER
Filter Specification
TFS 433 R
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedances*
for input:
for output:
Coupling coil:
23
°C
0 dBm
560
Ω ║
-1,25 pF
560
Ω ║
-1,25 pF
47 nH
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 433 R is the minimum of the pass band attenuation amin. The minimum of the pass
band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies
at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 433,92 MHz without tolerance. The given
values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below even if the centre
frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance
of centre frequency fc.
Data
Insertion loss
(Reference level)
Nominal frequency
Centre frequency
ae = amin
fN
fc
typ. value
3,8
-
433,95
BW
-
0,8
32
50
58
61
53
58
0,5
-
-
TC **
-0.036
ppm/K²
+ 20
°C
dB
dB
dB
dB
dB
dB
dB
µs
MHz
dB
tolerance/limit
max.
6,5
dB
433,920 MHz
Guaranteed 1,5 dB signal band width
Relative attenuation
fN ± 80 kHz
fN ± 460 kHz ... fN
fN ± 660 kHz ... fN
fN -
1 MHz ... fN
fN +
1 MHz ... fN
fN +
2 MHz ... fN
fN ±
5 MHz ... fN
Group delay ripple
fN ± 70 kHz
arel
± 660 kHz
±
1 MHz
- 13 MHz
+
2 MHz
+
5 MHz
± 13 MHz
GD
min.
max.
min.
min.
min.
min.
min.
min.
max.
160
1,5
25
40
50
50
47
50
2
kHz
dB
dB
dB
dB
dB
dB
dB
µs
°C
°C
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
Frequency inversion temperature
*)
- 40
°C
... + 85
- 40
°C
... + 85
-
-
The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**)
∆f(Hz)
= TCf(ppm/K²) x (T-T
0
)² x fTo(MHz)
Generated:
Checked / approved:
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
Vectron International Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail:
vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs433r.doc
version 3.1
24.05.2002
VI
TELEFILTER
(All dimensions in mm)
Filter Specification
TFS 433 R
2/5
Construction, pin configuration and 50
Ω
- matching network
5.0 SQ
-0.1
7
5
+0.15
433 R
P19
1
Date code
Pin 1
Pin 2
Pin 3
Pin 4,8
Input
Input RF Return
External Coil
Package Ground
Pin 5 Output
Pin 6 Output RF Return
Pin 7 Ground
Date code:
M
N
P
...
Year + week
2000
2001
2002
3
50 Ohm Test circuit 1
L1
1
5
L2
C1
SAW
3
2, 4, 6, 7, 8
L3
C2
50 Ohm Test circuit 2
C1
1
5
C2
L1
SAW
3
2, 4, 6, 7, 8
L3
L2
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
Vectron International Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail:
vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs433r.doc
version 3.1
24.05.2002
VI
TELEFILTER
Stability Characteristics
Filter Specification
TFS 433 R
3/5
After the following tests the filter shall meet the whole specification:
1. Shock:
2. Vibration:
3. Damp heat:
(cycle)
4. Resistance to
solder heat (reflow):
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type
II,
embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Reel of empty components at start:
Reel of empty components at start including leader:
Trailer
3000
min 300 mm
min 500 mm
min 300 mm
Tape (all dimensions in mm)
W
Po
:
:
12
4
± 0,3
± 0,1
P
o
EMBOSSED CARRIER TAPE
D
o
P
2
Do
:
E
:
F
:
G (min) :
P2
:
P1
:
D1(min) :
Ao
Bo
CT
:
:
:
1,5 + 0,1
1,75 ± 0,1
5,5 ± 0,05
0,75
2
8
1,5
5,3
5,3
9,5
± 0,05
± 0,1
± 0,1
± 0,1
± 0,1
CT
B
o
E
A
o
D
1
F
W
G
P
1
COVER TAPE
W2
Reel (all dimensions in mm):
A
W1
N (min)
C
:
:
:
:
330
12,4 + 0,2
18,4
50
13
+0,5 -0,2
A
C
N
W2 (max) :
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
Vectron International Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail:
vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs433r.doc
version 3.1
24.05.2002
VI
TELEFILTER
Air reflow temperature conditions
Filter Specification
TFS 433 R
4/5
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
180
temperature / °C
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
time / sec.
140
160
180
200
220
240
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
Vectron International Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail:
vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs433r.doc
version 3.1
24.05.2002
VI
TELEFILTER
History
Version
1.0
1.1
1.2
Reason of Changes
-
-
-
-
-
-
-
-
-
-
3.1
-
Filter Specification
TFS 433 R
5/5
Name
Dr. Wall
Dr. Wall
Dr. Wall
Date
14.03.2002
21.03.2002
22.04.2002
Generate specification according to customer requirements
Change pinning according to discussion with customer.
Change development specification to preliminary specification.
Add termination impedances.
Add typical data.
Position of coupling coil changed from pin 7 to pin 3
Change starting frequency for 25 dB selection from
fN ± 400 kHz to fN ± 460 kHz.
Change starting frequency for 40 dB selection from
fN ± 600 kHz to fN ± 660 kHz.
Change typical values.
Change termination impedances.
Change preliminary specification to filter specification.
1.3
3.0
Dr. Wall
Dr. Wall
23.04.2002
29.04.2002
Dr. Wall
24.05.2002
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
Vectron International Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail:
vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.