EEWORLDEEWORLDEEWORLD

Part Number

Search

RPS10E

Description
RPS10E
CategoryTools and equipment   
File Size292KB,3 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Download Datasheet View All

RPS10E Overview

RPS10E

Process Safeguarding
rKS & rPS
trapped rotary Key Power isolators
Direct drive operation, positively opens contacts
IP65 (NEMA 4) rated enclosure—water & dust resistant
Virtually maintenance free
Weatherproof stainless steel dust cap as standard
Up to 100 A isolation
4 N/O or 2 N/O + 2 N/C contacts
Conforms to EN292, EN1088, IEC947-5-1 & GS ET 19
UL listed & CSA approval on switches
RKS
r
C
US
Specifications
housing (rKS only)
Enclosure Rating:
Conduit Entries:
Ambient Temp:
Mechanical Operations:
Max. Shear Force to Key:
Max. Torque to Key:
Relative Operating Humidity:
Finger Protection:
Weight:
Code Barrels:
electrical Specifications
Electrical Operations RKS & RPS
Types:
Climatic Test:
Ambient Temp:
Rated Insulation Voltage (Ui):
Rated Impulse Withstand Vol. (Uimp):
S3 Intermittent Rating
(VDE 0530 Part 1) Duty Factor:
Rated Uninterrupted Current (Iu):
IEC/EN/VDE
UL /CSA
Rated Operational Voltage (Ue):
IEC/EN/SEV/VDE
UL/CSA
Main Switch isol. Voltage Up to:
Rated Operational Current (Ie):
AC-21A IEC/EN/VDE
AC-1 SEV
Rated Operational Power at 50 to
60 Hz:
AC-23A IEC/EN/VDE
3 Phase 220-240 V
3 Phase 380-440 V
500-690
AC-3 IEC/EN/VDE
3 Phase 220-240 V
3 Phase 380-440 V
500-690 V
IP65 (NEMA 4)
M20
-10 to 40°C (14 to 104°F)
>10
6
15.1 kN
14 Nm
25% to 95%
DIN 57106/VDE 0106 T.100
0.85 kg (2.21 lb.)
Tested to 1,000,000 operations
>10
5
Constant to DIN IEC 68 Part 2-3;
Variable to DIN IEC 68 Part 2-30
Encased -25 to 40°C (13 to 104°F)
690 V
6 kV
60/40/25%=1,3/1,6/2xlu
20 A
16 A
690 V
600 V
750 V
20 A
20 A
32 A
30 A
690 V
600 V
750 V
32 A
32 A
DOL-Rating UL/CSA
3 Phase 120 V
1.5 HP
3 Phase 240 V
3 HP
480 V
7.5 HP
600 V
10 HP
Rated Breaking Capacity:
AC-23/AC-3 220-240 V
250 A
Motor Switch 380-440 V
250 A
Max. Fuse Size (gL):
25 A
Rated Fused Short Circuit Current:
15 kA
Terminal Cross Section:
Single/Multiple Wire min. mm
2
1
max. mm
2
10
Fine Strand Wire
min. mm
2
0.75
w/ Sleeve max.
mm
2
6
American Wire Gauge:
8
Specifications are subject to change without notice.
3 HP
10 HP
20 HP
20 HP
330 A
330 A
35 A
15 kA
1
10
0.75
6
8
m
4 kW
7.5 kW
7.5 kW
3 kW
5.5 kW
5.5 kW
7.5 kW
15 kW
11 kW
5.5 kW
11 kW
11 kW
EN1088—Safety of Machinery, Interlocking devices associated with guards
“4.1.1 Control interlocking
The stop command from the interlocking device is introduced into the control system
so that the interruption of the energy supply to the machine actuators, or mechanical
disconnection of moving parts from the machine actuators, is triggered by the control
system (indirect interruption…)”.
“4.1.2 Power interlocking
The stop command from the interlocking device directly interrupts the energy supply to
machine actuators or disconnects moving parts from the machine actuators…”Directly”
means that, unlike control interlocking the control system does not play any intermediate
role in the interlocking function.”
m
OmrOn Scientific technOlOgieS, inc.
USA
Tel. 1/888/510-4357
canada
Tel. 1/866/986-6766
For the Latest Information
On the Internet:
www.sti.com
or
www.omron.ca
CS+ compilation error, prompting that the specified file cannot be found, please help
This is the first time I installed this, and I downloaded more than 600 megabytes of installation files from the official website.The project displays normally even without compilation. I don't unders...
liyancao001 Renesas Electronics MCUs
BeagleBone Black Design: Add cooling measures to your own test platform
[i=s]This post was last edited by anananjjj on 2018-9-4 22:02[/i] Last month, the BeagleBone Black I got in a forum activity unfortunately broke down!! I still don’t know which chip went wrong, so I h...
anananjjj DSP and ARM Processors
The microcontroller or UC3842 generates PWM
I want to make a DCDC conversion circuit. Should I use a sliding resistor or a microcontroller to adjust the PWM duty cycle?...
浅浅之一 Power technology
Safety interlock for electrostatic precipitator
[font=Arial]As a safety protection for electrostatic precipitators, French interlocking expert STI (SERV Trayvou Interverrouillage) has designed and manufactured an interlock with a key transfer mecha...
aone2008 Industrial Control Electronics
Looking for a part-time DSP engineer to port existing algorithms to 8127DSP qq392895043
Use the existing algorithm to port it to TI 8127 DSP....
cs9581 Recruitment
Op amp driving the cable shield
I use a double-shielded cable to transmit signals. The inner signal line (3V sawtooth wave) drives the shield layer (middle layer) after passing through the AD823 in-phase buffer. The outer shield lay...
wtl28 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 714  618  1921  2525  948  15  13  39  51  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号