EEWORLDEEWORLDEEWORLD

Part Number

Search

4301.8055

Description
PWR ENT MOD RCPT IEC320-C14 PNL
CategoryThe connector   
File Size1MB,11 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric Compare View All

4301.8055 Overview

PWR ENT MOD RCPT IEC320-C14 PNL

4301.8055 Parametric

Parameter NameAttribute value
Connector styleIEC 320-C14
Connector typeSocket, male blade - module
Current - IEC1A
Voltage - IEC250VAC
Current - UL1A
Voltage - UL125VAC
filter typeFiltering (EMI, RFI) - commercial, medical
fuseyes
Number of pins3
Installation typepanel mount, flange
TerminationQuick Connect - .250" (6.3mm)
switch function-
characteristic-
fuse holder, drawerDrawers sold separately
Panel opening sizeRectangle - 29.00mm x 33.00mm
Panel thickness-
Material flammability ratingUL94 V-0
Intrusion protectionIP40
ApprovalCCC,cULus,ENEC
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
KFA
IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, optional Voltage Selector (step switch)
Screw-on mounting from front side
Version with ground line choke
without voltage selector
Fuse drawer must be ordered separately (see
accessories).
Snap-in mounting from front side
without voltage selector
Fuse drawer must be ordered separately (see
accessories).
Screw-on mounting from rear side
without voltage selector
Fuse drawer must be ordered separately (see
accessories).
C14
Approvals and Compliances
70° C
See below:
Description
- Panel mount :
Screw-on version from front or rear side, snap-in version from front
side
- 4 Functions :
Appliance Inlet Protection class I , Fuseholder for fuse-links 5 x 20 mm
1- or 2-pole , with or without voltage selector (step switch) , Line filter
in standard and medical version
- V-Lock notch standard
- Quick connect terminals or wires
Characteristics
- Rear side mounting for efficient costsaving assembly
Suitable for assembly in metal plated plastic housings
- All single elements are already wired
- Plug removal necessary for fuse-link replacement
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
- Capacity CX 100 nF
Unique Selling Proposition
-
-
-
-
References
Weblinks
Reduces noise on the ground wire
Interrupts ground loops
High asymmetrical attenuation
V-Lock cord retaining
Alternative: version without line filter
KEA
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product, Microsite
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Flexible wire AWG18, 150 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 0.8 mm to 3 mm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
C14 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
optional, step, 3 pos.
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 1'700'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Tempe-
rature
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness S
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Voltage Selector
Line Filter
MTBF
Material: Housing
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: KFA
EMC Products
1

4301.8055 Related Products

4301.8055 4301.5011 20KDA60_15 4301.5003 4301.5014 4301.5004 4301.5249 4301.5202
Description PWR ENT MOD RCPT IEC320-C14 PNL 6A, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER, PLUG Standard Recovery Diode 6A, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER, PLUG 6A, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER, PLUG 6A, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER, PLUG PWR ENT MOD RCPT IEC320-C14 PNL PWR ENT MOD RCPT IEC320-C14
Connector type Socket, male blade - module MAINS POWER CONNECTOR - MAINS POWER CONNECTOR MAINS POWER CONNECTOR MAINS POWER CONNECTOR MAINS POWER CONNECTOR Socket, male blade - module
Installation type panel mount, flange PANEL - PANEL PANEL PANEL PANEL -
Is it lead-free? - Lead free - Lead free Lead free Lead free Lead free -
Is it Rohs certified? - conform to - conform to conform to conform to conform to -
package instruction - ROHS COMPLIANT - ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT -
Reach Compliance Code - compli - compli compli compli compliant -
Factory Lead Time - 8 weeks - 8 weeks 8 weeks 8 weeks 8 weeks -
Other features - STANDARD: IEC/EN 60320-1/C14, UL 498; UL 94V-0, CSA C22.2, VDE, QUICK CONNECT - STANDARD: IEC/EN 60320-1/C14, UL 498; UL 94V-0, CSA C22.2, VDE, QUICK CONNECT STANDARD: IEC/EN 60320-1/C14, UL 498; UL 94V-0, CSA C22.2, VDE, QUICK CONNECT STANDARD: IEC/EN 60320-1/C14, UL 498; UL 94V-0, CSA C22.2, VDE, QUICK CONNECT STANDARD: IEC/EN 60320-1/C14, UL 498; UL 94V-0, CSA C22.2, VDE, QUICK CONNECT -
Body/casing type - PLUG - PLUG PLUG PLUG PLUG -
Contact to complete cooperation - NOT SPECIFIED - NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED -
Contact point gender - MALE - MALE MALE MALE MALE -
Contact material - NOT SPECIFIED - NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED -
Coupling type - SNAP - SNAP SNAP SNAP SNAP -
DIN compliance - NO - NO NO NO NO -
IEC compliance - YES - YES YES YES YES -
MIL compliance - NO - NO NO NO NO -
Power Connector Ratings - 1A, 125/250VAC - 4A, 125/250VAC 6A, 125/250VAC 6A, 125/250VAC 10A, 125/250VAC -
Manufacturer's serial number - 4301 - 4301 4301 4301 KFA -
Options - GENERAL PURPOSE - GENERAL PURPOSE GENERAL PURPOSE GENERAL PURPOSE GENERAL PURPOSE -
Shell material - POLYETHYLENE - POLYETHYLENE POLYETHYLENE POLYETHYLENE POLYETHYLENE -
Termination type - SOLDER - SOLDER SOLDER SOLDER SOLDER -
Total number of contacts - 3 - 3 3 3 3 -
Base Number Matches - 1 - 1 1 1 1 -
A brief discussion of the insertion sort algorithm
[i=s]This post was last edited by michael_llh on 2016-10-11 20:20[/i] [align=left][size=4] When we are interviewing for software development positions in Internet companies, we will inevitably be test...
michael_llh Programming Basics
High-performance data acquisition system enhances digital X-ray and MRI images
High-Performance Data Acquisition Systems Enhance Digital X-Ray and MRI Images Digital X-ray (DXR), magnetic resonance imaging, and other medical devices require data acquisition systems that are smal...
youluo ADI Reference Circuit
What does IIHZ/IILZ mean?
Looking at the 74LVC4245A data sheet, there is IIHZ/IILZ, what does it mean?...
216hjk Test/Measurement
Digital Sampling Oscilloscope
Compared with the digital storage oscilloscope and digital phosphor oscilloscope structure, in the digital sampling oscilloscope structure, the attenuator/amplifier and sampling bridge are reversed, a...
一世轮回 Test/Measurement
Research on Reflow Process Technology
Abstract : With the development of surface mount technology, reflow soldering has attracted more and more attention. This article introduces the general technical requirements of reflow soldering, and...
gaoyanmei PCB Design
Has anyone used OP07 to adjust zero? How is the circuit connected when adjusting zero?
Has anyone used OP07 to adjust zero? How is the circuit connected when adjusting zero?...
陈铁牛 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1957  1343  2292  916  1637  40  28  47  19  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号