• FEP insulation is compatible with most insulation
displacement connectors
• .050 inch pitch parallel conductors for mass
termination
• Low dielectric constant
• Excellent abrasion and chemical resistance
• Excellent mechanical durability
• Nonflammable
• UL Recognized to 200°C
• See the Regulatory Information Appendix
(RIA) in the “RoHS compliance” section of
www.3Mconnectors.com for compliance
information (RIA E1 & C1 apply)
Date Modified: October 30, 2013
3601 Series
TS-0553-C
Sheet 1 of 3
Physical
Insulation:
Material: Flourinated Ethylene Propylene (FEP)
Color: Blue
Marking:
Conductors:
28 AWG, 7
×
36 AWG [ 7
×
Ø
0.127 ] Silver Plated Stranded Copper
Standard: None
Electrical
Unbalanced
Characteristic Impedance:
131
Ω
Voltage Rating:
USA: 300V
EU: <50V
Insulation Resistance:
> 1 × 10
10
Ω/10
ft. [ 3 m ]
9.9 pF/ft [ 32.5 pF/m ]
Capacitance:
Inductance:
Propagation Delay:
Velocity of Propagation:
0.17 μH/ft [ 0.56 μH/m ]
1.29 ns/ft [ 4.23 ns/m ]
79%
Note: Unbalanced is measured between ground-signal-ground conductors.
Environmental
Temperature Rating:
-55°C to +200°C
Flammability Rating:
USA: VW-1
UL File No.: E42769, Style No: 20424
3
Interconnect Solutions
http://www.3Mconnectors.com
3M is a trademark of 3M Company.
For technical, sales or ordering information call
800-225-5373
3M
™
Round Conductor Flat Cable
.050" 28 AWG Stranded, FEP
Number of
Conductors
04
06
08
10
12
14
15
16
20
25
26
30
34
40
50
60
64
3M Part
Number
3601/04
3601/06
3601/08
3601/10
3601/12
3601/14
3601/15
3601/16
3601/20
3601/25
3601/26
3601/30
3601/34
3601/40
3601/50
3601/60
3601/64
A
B
.025
±
.007
[0.64]
.050
±
.002 Typ
[1.27]
3601 Series
Dimension A
Dimension B
0.150 ± .007 [3.81]
0.250 ± .007 [6.35]
0.350 ± .007 [8.89]
0.450 ± .007 [11.43]
0.550 ± .007 [13.97]
0.650 ± .007 [16.51]
0.700 ± .007 [17.78]
0.750 ± .007 [17.78]
0.950 ± .011 [24.13]
1.200 ± .011 [30.48]
1.250 ± .011 [31.75]
1.450 ± .011 [36.83]
1.650 ± .015 [41.91]
1.950 ± .015 [49.53]
2.450 ± .015 [62.23]
2.950 ± .015 [74.93]
3.150 ± .015 [40.01]
0.200 ± .008 [5.08]
0.300 ± .008 [7.62]
0.400 ± .008 [10.16]
0.500 ± .010 [12.70]
0.600 ± .010 [15.24]
0.700 ± .010 [17.78]
0.750 ± .010 [19.05]
0.800 ± .010 [19.05]
1.000 ± .015 [25.40]
1.250 ± .015 [31.75]
1.300 ± .015 [33.02]
1.500 ± .015 [38.10]
1.700 ± .020 [43.18]
2.000 ± .020 [50.80]
2.500 ± .020 [63.50]
3.000 ± .020 [76.20]
3.200 ± .020 [81.28]
.029
±
.003
[0.74]
28 AWG, 7X 36 AWG [7X Ø 0.127]
Silver Plated Stranded Copper
Conductors
Inch
[mm]
Tolerance Unless Noted
.0
.00
±.01
.000
±.005
Inch
±.1
Note: Blue marking on one edge of cable designates wire #1.
[ ] Dimensions for Reference Only
Ordering Information
3601/XX
Number of Conductors
(See Table)
Note: Available in standard 100 ft rolls, contact 3M for availability of additional
conductor counts and/or custom roll lengths.
TS-0553-C
Sheet 2 of 3
3
Interconnect Solutions
http://www.3Mconnectors.com
3M is a trademark of 3M Company.
For technical, sales or ordering information call
800-225-5373
Important Notice
All statements, technical information, and recommendations related to 3M’s products are based on information believed to be reliable, but the accuracy or completeness
is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated
with such use. Any statements related to the product which are not contained in 3M’s current publications, or any contrary statements contained on your purchase order
shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M.
Warranty; Limited Remedy; Limited Liability.
This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase.
3M MAKES NO OTHER WARRANTIES
INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
If this product is defective within the
warranty period stated above, your exclusive remedy shall be, at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product.
Except
where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of
Hello everyone, recently I have been trying to port UCOS-II to the DSP C6701 platform, using the source code of UCOS-II V2.52. After creating the project, I directly added some codes into it, and then...
The magnetoelectric ammeter is an instrument commonly used in middle school physics to measure the current size of a closed loop. When the current passes through the coil, the wire is acted upon by th...
Functional test In functional test, the choice of test method is more important and should be reasonable. When verifying the multi-period prompt function, the method used is to replace "hours" with "m...
1. LoRa Technology
LoRa is an ultra-long-distance wireless transmission solution based on spread spectrum technology launched by Semtech Corporation of the United States. It belongs to the Low Power W...
Previously, we have been programming by directly reading and writing registers. We need to frequently look up the macro name in lm3s8962.h, which is very inconvenient and difficult to maintain. Now we...
On August 24th, Tesla CEO Elon
Musk
revealed information about the upcoming FSD V14, claiming it will outperform human drivers. Tesla FSD lead Ashok stated last year that FSD version 12.5, ...[Details]
The core of a machine vision system is image acquisition and processing. All information comes from images, and image quality is crucial to the entire vision system. A good image can improve the st...[Details]
Most of the houses we live in now are elevator buildings, mainly because it is more convenient to go up and down the stairs! It can also make life more comfortable. It even helps to increase the ad...[Details]
On August 22, according to the Ministry of Industry and Information Technology's official website, my country's first mandatory national standard for the control of hazardous substances in electric...[Details]
There are basically three causes of spontaneous combustion of electric vehicles: The first is that the battery components are punctured or suffer fatal damage due to a collision accident, and part ...[Details]
Tires are a very important component for cars. They are related to the driving experience of the vehicle. We are almost inseparable from cars in our daily lives. For tires, according to the role of...[Details]
1. Ease of Use: The HMI module should be designed to be simple and clear, allowing users to easily operate and configure the energy storage device.
2. Ease of Maintenance: The HMI module should...[Details]
On August 22, according to CNBC's report today, the National Highway Traffic Safety Administration (NHTSA) is launching an investigation into Tesla, and the latter is questioned whether it has fail...[Details]
I recently read an article in the Wall Street Journal titled "We need the right to repair our gadgets" (reference original article: ). The author was very angry about the phenomenon of "planned obs...[Details]
AI distributed rendering architecture improves mobile phone rendering capabilities, and game performance tests can check frame generation indicators in real time
Shanghai, China, Aug...[Details]
The characteristics of electric vehicles place high demands on the motors they use. To increase top speed, the motor should have high instantaneous power and power density (W/kg); to increase drivi...[Details]
Keysight Technologies reported strong third-quarter results, with revenue and earnings per share exceeding expectations and steady order growth. The company, driven by strong growth across multiple...[Details]
The consumer electronics, appliance, industrial, and automotive markets are experiencing increasing demand for sophisticated motor control solutions. Depending on the application, a variety of moto...[Details]
Motor potting compound is a high-performance sealing material widely used for motor encapsulation and insulation. It is essential for motor protection and packaging. Its ideal moisture and water re...[Details]
The main differences between xenon lamps and halogen lamps are as follows:
1. Xenon lamps rely on high-voltage arc discharge for lighting, so xenon lamps need to be equipped with an additional...[Details]