Class 1E qualified connector with quick connect 1/4 turn bayonet
coupling designed to operate safely during normal and seismic conditions
in various applications in the reactor containment buildings.
High sealing level
3
3
3
3
Submersion: 6 m of water; 24 hrs
Jet spray: 0,1MPa; 1 min
5
Temperature range: -10 to 70°C (1 to 1
4
58°F)
Radiation: 25 MRads at 20°C (68°F)
Salt spray resistance: 168 hrs
Environmental performances
Accident testing
Operating Basis Earthquake (OBE): 3g ZPA
Safe Shutdown Earthquake (SSE): 6g ZPA
Qualification standards
EDF HM63 / 7195, Class 1E K2;
RCC-E 1993 & 2002
8N45 Series
Reactor Containment Certified Connectors
Description
• Class 1E qualified connectors
• Quick connect ¼ turn bayonet coupling
• Qualification standards:
- EDF HM63 / 7195
- RCC-E 1993 & 2002
Applications
• Instrumentation, sensors, probes
Technical features
Electrical
• Current rating: 1 A max
1
• Peak current: 50A / 30ms
• Test Voltage rating: 2000 Vrms
• Insulation Resistance:
≥
5000 MΩ under
500 Vdc
• Contact resistance: 5 mΩ
• Shielding resistance:
≤
20 mΩ
Mechanical
• Mating / Unmating effort: 0,1 daN.m
2
• Endurance: 500 mating / unmating
• Cable clamp resistance:
Traction 50 N / Torsion 0,5 Nm
Environmental
• Ambient temperature:
-10 to 70°C (1 to 1
4
58°F)
• Max temperature: 85°C (185°F)
• Ambient humidity: 75% max.
• Cumulated radiation: 250 kGy (25 MRads) /
70°C (1
58°F)
• Dry heat test: 40°C (104°F) / 93% HR / 504h
• Salt spray resistance: 168h
• Protection against water penetration:
- IP X6
- IP 68
Seism / Vibration
• Seism:
- Operating Basis Earthquake (OBE): 3g ZPA
- Safe Shutdown Earthquake (SSE): 6g ZPA
• Vibration (Sine): 10 to 2000Hz; 0,35 mm; 5g
Materials
& Plating
Connector Part
Shells
Stainless Steel
Nickel (locally)
Insulator & grommet
Silicon
/
Seals
Silicon
/
Contacts
Copper alloy
(Zinc / Lead)
Gold over nickel
Material
Plating
2
8N45 Series
Reactor Containment Certified Connectors
Features & benefits
Class 1E Safety Connectors
Designed and manufactured according to RCC-E code
8N45 Series connectors meet the design and manufacturing rules of AFCEN’s RCC-E code, which stands as one
of the major worldwide references for safety electrical equipments of nuclear islands.
K2 Qualified for 40 years operation
8N45 Series connectors are K2 qualified according to RCC-E, which means they are suitable for use on safety
related equipments inside reactor building, under normal and seismic conditions. The qualified lifetime of 8N45
Series connectors is 40 years.
Approved quality assurance program
SOURIAU quality assurance program meets International & Nuclear standards:
• ISO/EN 9001: 2000
• ISO 1
7025
• SGAQ DIN-DPN 2004-04
• Q/N/100, Q/N/200, Q/N/300
• KTA 3507
• NQA-1-1994 & NQA-1a-1995
• 10 CFR50 Appendix B
• 10 CFR21
Applications
SOURIAU 8N45 series connectors are designed to be used for various applications in the
reactor containment building
• Instrumentation
• Control
Field proven
Used in main power plants
SOURIAU 8N45 Series has been extensively used in more than 60 PWR plants
(all types including 900, 1
300, 1
450 MW reactors).
40 years experience
With 40 years of successful usage without any failure experienced in the field,
the 8N45 Series guarantees a safe and reliable connection in the reactor
containment building.
3
8N45 Series
Reactor Containment Certified Connectors
Receptacle & backshell details
8N45 Square flange receptacle
2 types of receptacle backshells are available:
• Simple backnut (represented & described hereunder)
• Straight with cable clamp and sealing gland (refer to plug description
on next page)
F
G
H
ØA
11
21
16,00
20,00
B
33,50
33,50
C
15,40
15,40
D
24,00
27,00
ØE
18,60
22,60
ØF
3,2
3,2
ØG
19,00
23,00
H
H
18,00
21,00
Contact layouts
8N45 11
8N45 21
3#16
3 Contacts
Size
16
7 # 16
7 contacts size 16
4
8N45 Series
Reactor Containment Certified Connectors
Plug & backshell details
8N45 Plug details
2 types of plug backshells are available
• Simple backnut (refer to receptacle description on
previous page)
• Straight with cable clamp and sealing gland (described
hereunder)
Type *
1
1
21
21
51
21
A
80
80
80
ØB
22,50
22,50
26,50
Ø C min
7,50
10,50
10,50
Ø C max
9,50
1
2,00
1
2,00
D
23,00
23,00
23,00
* 2 types of straight backshells
with cable clamp and sealing
gland are available for shell
size 1 depending on cable
1
diameter
Ordering information
Product Series
Shell Size / Contact Layout
1
(3 contacts)
1
21
(7 contacts)
1: Receptacle
8: Plug
1:
Pin
5:
Socket
25:
Backnut
21*:
Straight backshell (Shell size 1 & 21)
1
51*:
Straight backshell (Shell size 1 only)
1
Blank:
K2 qualified product according to RCC-E code
NC:
Non-classified product
Blank:
Standard packaging
20:
Long duration packaging - without chlorine
8N45S
1
1
1
1
21
_
_
Shell Type
Contact Type
Backshell / Interface Type
Classification**
Packaging
* See definition table p.6 - ** K2 connectors are manufactured with specific traceability and delivered with End of Manufacturing Report, according to RCC-E code. NC connectors are
manufactured with standard traceability and delivered with Certificate of Conformity only.
What can BearPi HM Nano do? What functions can it achieve?
1. Learn Hongmeng operating system.
2. Communication and data exchange with the host function through the serial port
3. Turn on the LED ligh...
I would like to ask: what is 8251A called in protues? I have searched online but couldn't find it; nor is it in the detailed documentation; 8259A, 8253A, 8255A, all of these are there but not 8251A. I...
TI - MCU - MSP430 User Guide 1 - MSP430 Introduction and Selection Guide
TI - MCU - MSP430 User Guide 2 - CPU/CPUX
TI - MCU - MSP430 User Guide 3 - SYS System Control
TI - MCU - MSP430 User Guide 4 - ...
That is, I don't need to use the capture drawing function, but directly edit the netlist file, like pspice, I don't know how to do it, please give me some advice, thank you! ! ! ! ! ! ! ! ! ! ! ! !...
Many friends are learning or want to learn single-chip microcomputers, but after reading some materials, they either feel that they don’t know what to learn or can’t find the next learning method. Thi...
Assume that data is read from 8-bit AD (if it is a higher-bit AD, the data type can be defined as int), the subroutine is get_ad();
1. Limited secondary filtering
/* A value can be adjust...[Details]
1 Introduction
The high temperature tester is mainly used for temperature tracking measurement and data acquisition during the heating process. By systematically analyzing the test data, the...[Details]
Floating-point digital signal processing has become a constant requirement for precision technology, often in applications requiring high accuracy in areas such as aviation, industrial machinery, a...[Details]
1 Introduction
Solar street lights are mainly composed of four parts: solar photovoltaic cell components, batteries, charge and discharge controllers, and lighting fixtures. The bo...[Details]
Battery life is critical for portable applications. For applications such as smoke detectors, security devices, and thermostats, factory-installed batteries need to last for more than 10 years. The...[Details]
Overview
In spectral measurement, photomultiplier tubes (PMT) and charge-coupled devices (CCD) are often used as photoelectric converters. PMT is used in slow-changing, high-precision spectral...[Details]
Today, with energy becoming increasingly scarce, the utilization of natural energy has become the focus of people's attention. Among various natural energies, the endless solar energy is highly fav...[Details]
Since AC mains power may experience power outages, voltage sags and surges, continuous undervoltage and overvoltage, and frequency fluctuations during supply, these factors will affect the continuous ...[Details]
0 Introduction
Ultrasonic waves
are mechanical waves with a frequency of more than 20KHz, and the propagation speed in the air is about 340 m/s (at 20°C). Ultrasonic waves can be gene...[Details]
In industry, voltage 0…5 (10) V or current 0 (4)…20 mA is usually used as a method for analog signal transmission, which is also a method often used by programmable controllers. So what are the dif...[Details]
There are many types and styles of digital voltmeters in design and development. Traditional digital voltmeters have their own characteristics. They are suitable for manual measurement on site. Tra...[Details]
1 Introduction
Automatic Test
System The ATS (Automatic Test System) integrates all the stimulus and measurement equipment required for testing.
The computer
efficiently comp...[Details]
TPMS is the abbreviation of "Tire Pressure Monitoring System". It is mainly used to automatically monitor the tire pressure in real time when the car is driving, and to alarm for tire leakage and l...[Details]
Various electronic and electromagnetic interference inside and outside the car often puts automotive electronic equipment in dangerous working conditions, degrading the performance of electronic eq...[Details]
As the automobile consumer market heats up, the safety performance of automobiles has attracted more attention from consumers. When driving at high speed, tire failure is the most worrying and diff...[Details]