EEWORLDEEWORLDEEWORLD

Part Number

Search

TPMPU50-215

Description
50W Desk Top Switching Power Supplies For Medical Equipment.
File Size294KB,2 Pages
ManufacturerTotal Power International
Websitehttp://www.total-power.com/
Download Datasheet View All

TPMPU50-215 Overview

50W Desk Top Switching Power Supplies For Medical Equipment.

TPMPU50 SERIES
50W Desk Top Switching Power Supplies For Medical Equipment.
Description:
The TPMPU50 series of AC/DC switching mode power supplies
provide 50 Watts of continuous output power. All supplies are UL
94V-0 compliant, include IEC-320-C14 input for worldwide
applications. All models meet FCC Part-15 class B and CISPR -11
EN55011 class B emission Limits and are designed to comply with
UL, C-UL, CB and CE requirements. All units are 100% burned in
and tested.
Features:
+
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
+
IEC-320-C14 Input Inlet
+
Single to Triple Output
+
Output Voltage Available From 2VDC Thru 50VDC
+
Optional Output Connector (See appendix)
+
Input Surge Current, Over Voltage And Over Load protection
+
Splash proof
+
Two Year Warranty
Safety Approvals :
C
US
EN 60601-1
Electrical Characteristics:
Sym.
Vin
Fin
Wo
Vo
Io
Iil
Iih
Irl
Irh
Eff
REG-i
REG-o
OVP
OCP
Ttr
Thold
Ts
Vrn
Ilk
Tc
CB
Typ.
Max.
Unit
VAC
Hz
W
V
A
A
A
A
A
%
%
%
%
%
mS
mS
1.5
1
2
2
0.1
0.04
S
%
mA
%/
°c
Parameter
Input Voltage
Input Frequency
Output Power Range
Output Voltage Range
Output Current Range
Input Current (Low Line)
Input Current (High Line)
Low Line Inrush Current
High Line Inrush Current
Efficiency
Line Regulation
Load Regulation
Over Voltage Protection
Over Current Protection
Transient Response
Hold-Up Time
Start Up Time
Ripple & Noise (Pea k to Peak)
Safety Ground Leakage Current
Temperature Coefficient
Test Conditions
Min.
Vin=90 to 264VAC
Io=Full load,
Io=Full load,
Io=Full load,
Vin=115VAC
Io=Full load,
Vin=230VAC
Io=Full Load,
Io=Full Load
Vin=230VAC
Vin=115VAC
Vin=230 VAC
25
°c
, Cool start,
25
°c
, Cool start,
Vin=230VAC
90
264
47
63
0
50
See rating chart
See rating chart
1.35
0.7
12
26
75
83
0.5
3
112
110
15
30
88
1
7
132
150
4
16
0.3
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=110VAC
Io=Full Load, Vin=100VAC
Full Load, Vin=90VAC
Io=Full Load, Vin=240VAC
All output
-0.04
Environmental :
Sym.
Toper
Tstg
Hr
Pd
Parameter
Test Conditions
Min.
0
-40
5
Typ.
Max.
70
85
95
Unit
°c
°c
%
Operating Temperature
Storage Temperature
Relative Humidity
Derate linearly from 100% load at 50°c to 50% load at 70°c
Safety Specifications:
Sym.
Vps
Parameter
Test Conditions
Primary to secondary
Primary to ground
Test Voltage = 500VDC
Vin=220VAC
Vin=110VAC
Min.
5656
2121
50
B
B
Typ.
Max.
Unit
VDC
VDC
MW
CLASS
CLASS
Dielectric Withstanding Voltage
for Primary to secondary
Dielectric Withstanding Voltage
Vpg
for Primary to ground
Ri Isolation Resistance
CISPR EMI requirements for CISPR-11
FCC EMI requirements for FCC PART-15

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 883  2147  2570  802  14  18  44  52  17  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号