EEWORLDEEWORLDEEWORLD

Part Number

Search

FMC35DREN

Description
Card Edge Connector, 70 Contact(s), 2 Row(s), 0.1 inch Pitch, Green Insulator
CategoryThe connector    The connector   
File Size277KB,3 Pages
ManufacturerSullins Connector Solutions
Environmental Compliance  
Download Datasheet Parametric View All

FMC35DREN Overview

Card Edge Connector, 70 Contact(s), 2 Row(s), 0.1 inch Pitch, Green Insulator

FMC35DREN Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid1157038197
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresNONE
body width0.4 inch
subject depth0.431 inch
body length4.135 inch
Connector typeCARD EDGE CONNECTOR
Contactor designPREASSEM CONN
Contact to complete cooperationNOT SPECIFIED
Contact completed and terminatedGold (Au) - with Nickel (Ni) barrier
Contact materialNOT SPECIFIED
contact modeRECTANGULAR
Contact resistance10 mΩ
Contact styleBELLOWED TYPE
Dielectric withstand voltage600VDC V
maximum insertion force4.448 N
Insulation resistance5000000000 Ω
Insulator colorGREEN
insulator materialGLASS FILLED POLYPHENYLENE SULFIDE
JESD-609 codee4
Plug contact pitch0.1 inch
Number of rows loaded2
Maximum operating temperature200 °C
Minimum operating temperature-65 °C
Plating thickness30u inch
Rated current (signal)3 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.225 inch
Total number of contacts70
Evacuation force-minimum value.278 N
8
7
6
5
4
3
2
1
REVISIONS
REV.
A
ECO. NO
1750
DESCRIPTION
INITIAL RELEASE
DATE
7-10-08
BY
MNH
F
E
F
D
B
A
E
.100 2.54
2X
.125 3.18
E
.075[1.90]
CARDSLOT
C
F
D
A
.186 4.72
.245 6.22
.431 10.95
.265 6.73
INSERTION
DEPTH
D
FITS
C
.043 MIN HOLE
.032 0.81
_ _C_ _ DSXH
.025 0.64
.160±.025 4.06±0.64
TAIL LENGTH
C
A
SECTION A - A
CONTACT MARKINGS
B 1 2 3 ... 60 B
A 1 2 3 ... 60 A
B
B
A
NOTES:
1. INSULATOR MATERIAL: SEE PART NUMBER CODING
2. CONTACT MATERIAL: SEE PART NUMBER CODING
3. PLATING: SEE PART NUMBER CODING
CONTACT ID
4. OPERATING TEMPERATURE: SEE PART NUMBER CODING
SCALE 2:1
5. PROCESSING TEMP: SEE PART NUMBER CODING
6. UL FLAMMABILITY RATING: 94V-0
7. VOLTAGE RATING: 600 VDC MINIMUM AT SEA LEVEL.
8. CURRENT RATING: 3 AMP PER CONTACT
9. VOLTAGE DROP: 30 MILLI VOLT AT RATED CURRENT
10. INSULATION RESISTANCE: 5000 MEGA OHM
11. CONNECTOR IDENTIFICATION: THE PART SHALL BE MARKED WITH A PART
NUMBER AND BARCODE
12. BOARD THICKNESS ACCOMMODATED: .062 .008"
13. BOARD INSERTION FORCE: 16 OZ MAX PER CONTACT PAIR WHEN USING A .062" TEST BLADE.
INTERNAL INSPECTION TO BE PER SULLIN'S WORK INSTRUCTION W17.3-01.
14. BOARD WITHDRAWAL FORCE: 1 OUNCE MINIMUM PER CONTACT PAIR USING .062" PCB
8
7
6
5
CUSTOMER COPY
UNLESS OTHERWISE SPECIFIED:
DATE
DRAWN
NAME
Pb
R
oHS COMPLIANT
4
DIMENSIONS ARE IN INCHES[MM]
TOLERANCES:
ANGULAR: 30'
.XX= .02 [.508]
.XXX= .005 [.1270]
.XXXX= .0005 [.0127]
SURFACE FINISH: 63 Ra
7-10-08
MNH
REMOVE ALL BURRS AND SHARP EDGES .010 MAX
THE INFORMATION HEREIN CONTAINS
PROPIETARY INFORMATION OF
SULLINS ELECTRONICS AND IS NOT
DESCRIPTION
TO BE REPRODUCED, USED OR
DISCLOSED TO OTHERS FOR ANY
PURPOSE EXCEPT AS SPECIFICALLY
PART NUMBER
AUTHORIZED IN WRITING BY AN
OFFICER OF SULLINS ELECTRONICS.
CONNECTOR, .100 CC LP
REV
A
_ _ C _ _ DSX _
SIZE DWG. NO.
INTERPRET DIMENSIONS AND GEOMETRIC
TOLERANCING
PER: ANSI Y14.5M-1994
3
2
C
C11127
1
A
SHEET 1 OF 3
SCALE: 2:1
FILE NAME: Z:\COMPONENTS\Part Assemblies\Customer Drawings\Customer Drawings for Catalog\C11127, _ _C_ _DSX _ PRINT: 7/10/2008
89S51
I now want to use P10---P16 of P1 port as input and P17 as output. How should I write this program using C51?...
munitis Embedded System
Small signal amplification
I want to amplify the differential small signal output by the pressure sensor 0~4mV (common mode 1.5V) to 0~200mV. I have used several instrumentation op amps. The gain is very small for small signals...
860208cnn Analog electronics
How to use the osal_set_event(task_id,event_flag) function?
[color=#666666][font=arial, 宋体]Is the osal_set_event(task_id,event_flag) function only used in task polling? For example, if I define a new event EVT, do I need to use this function to add the event t...
mr_j RF/Wirelessly
PPP protocol! Cannot get IP address during link establishment!
During the PPP protocol link establishment process! Both LCP and PAP passed! At the NCP stage! As soon as I sent a message to the ISP requesting an IP, I received a link termination message! I was kic...
dangl Embedded System
Transformer design formula (EXCEL format, suitable for power supplies below 150W)!!
1. Enter the output parameters of the switching power supply you want to design into the table. This table lists 4 output parameters, namely voltage output 1, current output 1; voltage output 2, curre...
potiancpu Power technology
Write the download program to MCU
Write the download program to MCU...
a7016 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2675  559  411  1299  1023  54  12  9  27  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号