Thermal Overcurrent Circuit Breaker 3120-F...
Description
An extremely versatile range of rocker switch/thermal circuit breakers
(S-type TO CBE to EN 60934 with trip free mechanism) offering the
choice of single pole, double pole with single pole protection, and
double pole with protection on both poles. Designed for snap-in panel
mounting with versions available for different panel cut-out sizes.
Illumination is optional and there is a range of colours and markings for
the rocker. Under overload conditions the rocker returns to the OFF
position. 6way frame for 3120-F5 available upon request.
Any one of the following additional function modules can be supplied
factory fitted to the rear of the switch/circuit breaker.
q
Under voltage release coil (for double pole versions only).
q
Magnetic trip coil for short circuit protection.
q
Magnetic trip coil for remote relay trip.
q
Auxiliary contacts for status signalling.
q
Mechanical slide interlock.
Approved to CBE standard EN 60934 (IEC 60934).
1
3120-F...
Technical data
Voltage rating
Current ratings
Typical life
AC 240 V; DC 50 V
(AC 250 V UL/CSA)
0.1...20 A (up to 30 A to special order, single pole only)
Typical applications
Motors, transformers, solenoids, extra low voltage wiring systems,
office machines, electro-medical equipment, power supplies,
communications systems.
Standard current ratings and typical internal resistance values
Current
rating
(A)
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.2
1.5
2
2.5
3
Internal
resistance per
pole (Ω)
94
24
12
5.30
4.20
2.90
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
Current
rating
(A)
3.5
4
4.5
5
6
7
8
10
12
14
16
18
20
Internal
resistance per
pole (Ω)
0.0565
0.0435
0.0435
0.0325
0.0215
0.0165
0.0165
<0.02
<0.02
<0.02
<0.02
< 0.02
< 0.02
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664A)
50,000 operations for I
N
≤16
A double pole
30,000 operations for I
N
≤16
A single pole,
10,000 operations for I
N
>16 A
-30...+60
°C
(-22...+140
°F)
Rated impulse
Pollution
withstand voltage degree
2.5 kV
2
reinforced insulation in operating area
Test voltage
AC 3,000 V
AC 1,500 V
>100 MΩ (DC 500 V)
0.1...2 A
10 x I
N
2.5...20 A 250 A 2 pole, or 150 A 1 pole
I
N
U
N
2 pole
0.1... 2 A
AC 250 V
200 A
2.5... 3 A
AC 250 V
1,000 A
3.5... 8 A
AC 250 V
2,000 A
9 ... 16 A
AC 250 V
3,500 A
18... 20 A
AC 250 V
5,000 A
0.1...20 A
DC 50 V
1,000 A
operating area IP 40
(IP 54 with water splash protection)
terminal area IP 00
8 g (57-500 Hz),
±0.61
mm (10-57 Hz)
to IEC 60068-2-6, Test Fc
10 frequency cycles/axis
30 g (11 ms)
to IEC 60068-2-27, Test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, Test Ka
240 hours at 95 % RH,
to IEC 60068-2-3, Test Ca
approx. 33 g (double pole)
approx. 27 g (single pole)
Dielectric strength
(IEC 60664 and 60664A)
operating area
between poles (2 pole)
Insulation resistance
Interrupting capacity I
cn
Interrupting capacity
(UL 1077)
Approvals
Authority
VDE, Semko
(EN 60934)
LRoS, BV
UL, CSA
Voltage ratings
AC 240 V, DC 28 V
DC 50 V
DC 50 V
AC 250 V, DC 28 V
AC 250 V, DC 50 V
Current ratings
0.1...20 A
0.1...20 A double pole
0.1...10 A single pole
0.1...20 A
0.1...20 A
Degree of protection
(IEC 60529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
single pole two poles in parrallel up to 30A
Illumination voltage/power consumption
operating voltage
6V
12 V
24 V
48 V
115 V
230 V
power consumption
filament/neon
LED
60 mA
20 mA
20 mA
20 mA
< 1 mA
< 1 mA
9 mA
9 mA
9 mA
1,5 mA
Mass
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications without
notice is reserved.Product markings may not be exactly as the ordering codes. Errors and
omissions excepted.
Issue D
¤
USA (847) 827-7600 - www.e-t-a.com -
¤
CANADA (905) 764-9510
69
Thermal Overcurrent Circuit Breaker 3120-F...
Ordering information
Type No.
3120 rocker switch/circuit breaker
Mounting
F snap in frame
Size of frame
panel thickness
3 to fit mounting cut-out 50.5x21.5 mm 1-6.35 mm (.039-.250 in)
4 to fit mounting cut-out 44.5x22 mm
1-2.5 mm (.039-.099 in)
5 to fit mounting cut-out 44.5x 22 mm 2.6-4 mm (.102-.158 in)
6 to fit mounting cut-out 45x33.7 mm
1.2-2.4 mm (.047-.094 in)
Number of poles
0 2 pole, unprotected, switch only
1 1 pole, thermally protected
2 2 pole, thermally protected
5 2 pole, thermally protected on one pole only (terminals 11, 12k, 12i)
6 1 pole, unprotected, switch only
Mounting frame design
1 collar height 1 mm (.040 in)
3 collar height 9 mm (.354 in)
4
collar height 2 mm with water splash protection (IP 54), not with -F6...
Terminal configuration
P7 blade terminals 2x2.8x0.8 mm (QC 2x.110) (terminals 12(k),
22(k),11, 21), not for under voltage module, not for switch
H7 12(k), 22(k): blade terminals 2x2.8-0.8 (QC 2x.110)
11, 21: terminal screws, not for switch
N7 as P7, but including shunt terminals 12(i) and 22 (i)
as blade terminals 2x2.8x0.8 mm(QC 2x.110)
not for under voltage module
G7 as H7, but including shunt terminals 12(i) and 22 (i)
as blade terminals 2x2.8x0.8 mm(QC 2x.110)
Characteristic curve
T1
thermal, 1.01-1.4 x I
N
Q1 switch only
Actuator style
W rocker
U momentary switch action
Switch color designation
opaque
translucent
(for illuminated versions)
01 black
12 white
02 white
14 red
04 red
15 orange
19 green
Rocker markings
D
L
F
X
I
I
ON
0
0
OFF
OFF
Typical time/current characteristics
Single or double pole load
0.1...2 A
10000
+60
°C
+140
°F
+23
°C
+73.4
°F
1000
-30
°C
-22
°F
1
Trip time in seconds
100
10
1
0.1
1
2
4
6 8 10
… times rated current
20
40
2.5...20 A
10000
+60
°C
+140
°F
+23
°C
+73.4
°F
1000
-30
°C
-22
°F
Trip time in seconds
100
ON
10
D L F X
X = without marking
Rocker illumination (optional)
B
filament≤ 48V AC/DC; neon
≥115V
AC
G green LED, AC/DC = 24V AC/DC
Y yellow LED, AC/DC
R red LED, AC/DC
Illumination voltage range
0
4 - 7 V (B,G,Y,R)
1
10 - 14 V (B,G,Y,R)
2
20 - 28 V (B,G,Y,R)
3
90 - 140 V (B)
4 185 - 275 V (B)
5
42 - 54 V (B,Y,R)
Current ratings
0.1...20 A
3120 - F
3120 - F
3 2 1 - N7 T1 - W 14 D B 4 - 5 A
.
0 . - N7 Q1 - W ..
.
.
. - 20 A
ordering example
(switch only)
1
0.1
1
2
4
6 8 10
… times rated current
20
40
The time/current characteristic curve depends on the ambient temperature
prevailing. In order to eliminate nuisance tripping, please multiply the circuit
breaker current ratings by the derating factor shown below. See also section 9
– Technical information.
Ambient temperature
°F
-22 -4
+14 +32 +73.4 +104 +122 +140
°C
-30 -20 -10 0
+23
+40 +50 +60
Multiplication factor
0.8 0.76 0.84 0.92 1
1.08 1.16 1.24
NOTE:
Switch only versions must be specified with -N7 or -G7 terminals.
Terminals 12(k) and 22(k) are not fitted.
70
¤
USA (847) 827-7600 - www.e-t-a.com -
¤
CANADA (905) 764-9510
Issue D
Thermal Overcurrent Circuit Breaker 3120-F...
Internal connection diagrams
2 pole,
thermally protected on both poles
11
line
21
Mounting style variants
2 pole,
thermally protected on one pole only
11
line
Style F 3.3
collar height 9 mm (.354 in.)
21
9
.354
12(i)
12(k)
22(i)
22(k)
12(i)
12(k)
22(i)
25
.984
19.5
.768
54
2.13
35
1.38
load
load
35
1.38
33
1.30
1
10
.394
1 pole,
thermally protected
11
line
2 pole,
unprotected
11
line
21
12(i) 12(k)
11
12(i)
12(k) load
22(i)
12(i)
load
22(i)
3
10.7
3.5
.421
.118
.138
21
15.5
.827
.610
41
blade terminals DIN 46244-C-Ms-S
(QC 2x .110)
1.61
flat head screw M3.5x5-MS ISO1580
tightening torque max. 0.8 Nm
Dimensions
Style F3.1
collar height 1 mm
25
.984
16
.630
Actuating force max. 35 N
optional illumination in ON position
OFF position
54
2.13
Style F 3.4
collar height 2 mm (.079 in.), with water splash protection
27
1.06
19.5
.768
56
2.21
35
1.38
10
.394
3.8
.150
33
1.30
7
.276
12(i) 12(k)
11
12(i)
12(k)
11
21
15.5
.827
.610
41
blade terminals DIN 46244-C-Ms-S
1.61
(QC 2x .110)
flat head screw M3.5x5-MS ISO1580
tightening torque max. 0.8 Nm
35
1.38
33
1.30
10.7
.421
3.5
.138
3
.118
.394
10
Style F 4.1
7
.276
10.7
3.5
.138
.421
21
15.5
.610
.827
blade terminals DIN 46244-C-Ms-S
(QC 2x.110)
flat head screw ISO1580 M3.5x5-MS
tightening torque max. 0.8 Nm
3
.118
25
.984
16
.630
Optional illumination
48
1.89
41
1.61
35
1.38
33
1.30
12(i) 12(k)
11
10
.394
Installation drawing
When installing the circuit breaker apply pressure on bezel only
operating area
3
10.7
3.5
.421
.118
.138
21
15.5
.827
.610
41
blade terminals DIN 46244-C-Ms-S
1.61
(QC 2x .110)
flat head screw M3.5x5-MS ISO1580
tightening torque max. 0.8 Nm
Style F 5.1
7
.276
25
.984
16
.630
Optional illumination
48
1.89
10
.394
15.5
.610
35
1.38
33
1.30
7
.276
7
.276
8
.315
mounting area
7
10
.276 .394
15.5
21
.610
.827
41
blade terminals DIN 46244-C-Ms-S
1.61
(QC 2x .110)
flat head screw M3.5x5-MS ISO1580
tightening torque max. 0.8 Nm
10.7
.421
3.5
.138
3
.118
This is a metric design and millimeter dimensions take precedence
(
inch
)
mm
Dimension diagram for style F6 is available on request.
Issue D
¤
USA (847) 827-7600 - www.e-t-a.com -
¤
10
.394
12(i)
12(k)
11
12(i) 12(k)
11
10
.394
CANADA (905) 764-9510
71
Thermal Overcurrent Circuit Breaker 3120-F...
Accessories
Insulated cover
Y 303 068 01
Rear terminal shroud black
Y 304 275 01
(IP64)
40.5
1.59
1.75
-0.25
.069
+.020
-.010
+0.5
2.5
.098
.354
R3
4
.13 .5
.157
8
13.5
.531
4
.157
3.7
.146
10
.394
Terminal adapter
Y 303 862 01
ø8
.315
blade terminal DIN 46244-C-Ms-S
(QC 2x.110)
Water splash cover, transparent
(IP66)
for styles -F4../-F5...
X 221 619 01
48
1.89
58
2.28
50.5
1.99
ø8
.315
*
* Y 303 675 01 suitable for
panel thickness < 2 mm (.079 in)
* Y 303 675 02 suitable for
panel thickness < 4 mm (.157 in)
60
2.36
73
2.87
3.4
.134
ø4.4
.173
22
.866
28
1.10
Retaining clip for 3120-F5...
Y 303 676 01
52
2.05
44.5
1.75
Cut-out dimensions
1
.039
22.5
.886
28
1.10
1
.039
Cut-out for mounting style -F3
with rocker and push button
sharp-edged
.039-.250
1-6.35
Cut-out for mounting style -F6
with rocker
panel thickness
min. 2.5
min .098
max. R2
max .079
50.5
+0.3
1.99
+.012
max. R0.3
max .012
35
1.38
16.5
.650
25
.984
Retaining clip for 3120-F3...
Y 303 675 01/02
70
+5
2.76
+.197
20
.787
50
1.97
1
0.9
.035
9
20.5
.807
min. 2
min .079
max. R1.5
max .059
max. R0.3
max .012
without bends
0.8
.031
2.5
.098
“A”
1.33
+.008
- .002
.846
+.008
21.5
+0.2
Blanking piece in -F3 frame
Y 303 885 31
54
2.13
31
1.22
matt finish
25
.984
16.5
.650
1-2.5 mm for ...F4
.039-.098 in.
2.6-4 mm for ...F5
.102-.157 in.
Cut-out for mounting style -F4/-F5
with rocker
min. 2
min .079
max. R1.5
max .059
1
.039
33
1.30
36
1.42
44.5
+0.2
1.75
+.008
.866
+.012
22
+0.3
mm 1.2
+0.4
1.6
+0.8
2.4
+1
panel
thickness inch .047
+.016
.063
+.031
.094
+.039
+1.1
+0,2
+2.2
dimension mm 45
- 0.05
45
- 0.05
45
- 0.05
“A”
inch 1.77
+.008
1.77
+.043
1.77
+.087
- .002
- .002
- .002
max. R0.3
max .012
Edges of working parts: DIN 6784
41
1.61
21
.827
This is a metric design and millimeter dimensions take precedence
(
inch
)
mm
72
¤
USA (847) 827-7600 - www.e-t-a.com -
¤
CANADA (905) 764-9510
33.7
- 0.05
+0.2
Issue D
Thermal Overcurrent Circuit Breaker 3120-F...
Description
Switch/thermal trip free circuit breaker (S-type TO CBE to EN 60934)
with standard isolator style two button operation. Single button press-
to-reset version also available. Both types can be supplied in single
pole configuration only, in double pole with single pole protection, and
in double pole with protection on both poles. Designed for snap-in
panel mounting. There is a choice of push button colour combinations
and illumination is optional.
Any one of the following additional function modules can be supplied
factory fitted to the rear of the switch/circuit breaker:
q
Under voltage release coil (for double pole versions only).
q
Magnetic trip coil for short circuit protection.
q
Magnetic trip coil for remote relay trip.
q
Auxiliary contacts for status signalling.
q
Mechanical slide interlock.
Approved to CBE standard EN 60934 (IEC 60934).
1
3120-F...
Technical data
Voltage rating
Current ratings
Typical life
AC 240 V; DC 50 V
(AC 250 V UL/CSA)
0.1...20 A (up to 30 A to special order, single pole only)
Standard current ratings and typical internal resistance values
Current
rating
(A)
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.2
1.5
2
2.5
3
Internal
resistance per
pole (Ω)
94
24
12
5.30
4.20
2.90
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
Current
rating
(A)
3.5
4
4.5
5
6
7
8
10
12
14
16
18
20
Internal
resistance per
pole (Ω)
0.0565
0.0435
0.0435
0.0325
0.0215
0.0165
0.0165
<0.02
<0.02
<0.02
<0.02
< 0.02
< 0.02
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664A)
50,000 operations for I
N
≤16
A double pole
30,000 operations for I
N
≤16
A single pole,
10,000 operations for I
N
>16 A
-30...+60
°C
(-22...+140
°F)
Rated impulse
Pollution
withstand voltage degree
2.5 kV
2
reinforced insulation in operating area
Test voltage
AC 3,000 V
AC 1,500 V
>100 M
Ω
(DC 500 V)
0.1...2 A
2.5...20 A
I
N
0.1... 2 A
2.5... 3 A
3.5... 8 A
9 ... 16 A
18... 20 A
0.1...20 A
10 x I
N
250 A 2 pole, or 150 A 1 pole
U
N
2 pole
AC 250 V
200 A
AC 250 V
1,000 A
AC 250 V
2,000 A
AC 250 V
3,500 A
AC 250 V
5,000 A
DC 50 V
1,000 A
Dielectric strength
(IEC 60664 and 60664A)
operating area
between poles (2 pole)
Insulation resistance
Interrupting capacity I
cn
Interrupting capacity
(UL 1077)
Approvals
Authority
VDE, Semko
(EN 60934)
LRoS, BV
Voltage ratings
AC 240 V, DC 28 V
DC 50 V
DC 50 V
AC 250 V, DC 28 V
Current ratings
0.1...20 A
0.1...20 A double pole
0.1...10 A single pole
0.1...20 A
0.1...20 A
Degree of protection
(IEC 60529/DIN 40050)
Vibration
UL, CSA
AC 250 V, DC 50 V
single pole two ples in parrallel up to 30 A
operating area IP 40
terminal area IP 00
8 g (57-500 Hz),
±0.61
mm (10-57 Hz)
to IEC 60068-2-6, Test Fc
10 frequency cycles/axis
30 g (11 ms)
to IEC 60068-2-27, Test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, Test Ka
240 hours at 95 % RH,
to IEC 60068-2-3, Test Ca
approx. 33 g (double pole)
approx. 27 g (single pole)
Shock
Corrosion
Illumination voltage/power consumption
operating voltage
6V
12 V
24 V
48 V
115 V
230 V
power consumption
filament/neon
LED
60 mA
20 mA
20 mA
20 mA
< 1 mA
< 1 mA
9 mA
9 mA
9 mA
1,5 mA
Humidity
Mass
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications without
notice is reserved.Product markings may not be exactly as the ordering codes. Errors and
omissions excepted.
Issue D
¤
USA (847) 827-7600 - www.e-t-a.com -
¤
CANADA (905) 764-9510