Search

ABPDNNT060MDAA5

Description
Board interface pressure sensor BASIC PRESSURE SENSOR
CategoryThe sensor    Pressure sensor    Machine interface pressure sensor   
File Size2MB,14 Pages
ManufacturerHoneywell
Websitehttp://www.ssec.honeywell.com/
Download Datasheet Parametric View All

ABPDNNT060MDAA5 Online Shopping

Suppliers Part Number Price MOQ In stock  
ABPDNNT060MDAA5 - - View Buy Now

ABPDNNT060MDAA5 Overview

Board interface pressure sensor BASIC PRESSURE SENSOR

ABPDNNT060MDAA5 Parametric

Parameter NameAttribute value
MakerHoneywell
Product CategoryBoard interface pressure sensor
Shipping restrictionsMouser does not currently sell this product.
seriesABP
Basic Board Mount Pressure Sensors
ABP Series—High Accuracy, Compensated/Amplified
60 mbar to 10 bar | 6 kPa to 1 MPa | 1 psi to 150 psi
Digital or Analog Output, Liquid Media Capable
32305128
Issue E
Datasheet
improving resolution and system accuracy. Optional internal
diagnostics validate that the sensor readings are correct.
• Flexible: Supply voltage range, variety of pressure units,
types, and ranges, output options, and wide operating
temperature range simplify use in the application.
• Versatile: Wet-media compatibility, sleep mode, and
temperature output options make the sensor a versatile
choice for Internet of Things applications.
• Honeywell Brand: Utilize proprietary Honeywell technology,
and are protected by multiple global patents.
DIFFERENTIATION
• Enhanced accuracy helps the design engineer fully
understand the error in measurement.
• Wide supply voltage range offers design flexibility.
• Power consumption when utilizing sleep mode option allows
for use in battery-powered applications.
DESCRIPTION
The ABP Series are piezoresistive silicon pressure sensors
offering a ratiometric analog or digital output for reading
pressure over the specified full scale pressure span and
temperature range. They are calibrated and temperature
compensated for sensor offset, sensitivity, temperature
effects and accuracy errors (which include non-linearity,
repeatability and hysteresis) using an on-board Application
Specific Integrated Circuit (ASIC). Calibrated output
values for pressure are updated at approximately 1 kHz for
analog and 2 kHz for digital. All products are designed and
manufactured according to ISO 9001 standards.
• Dry gases option: The input port is limited to non-corrosive,
non-ionic media (e.g., dry air, gases) and should not be
exposed to condensation. The gases are limited to media
compatible with high temperature polyamide, silicone,
alumina ceramic, silicon, gold, and glass.
• Liquid media option: Includes an additional silicone-based
gel coating to protect the electronics under port P1, which
enables use with non-corrosive liquids (e.g. water and
saline) and in applications where condensation can occur.
Since port P2 is designed for use with non-corrosive liquids,
this option is often suitable for wet-wet differential sensing.
VALUE TO CUSTOMERS
• Simplifies design-in: Small size saves room on the PC board
(PCB), or simplifies design in smaller and lower power
devices. Meets Moisture Sensitivity Level 1 requirements,
which allows for unlimited shelf life when stored at
<30 ºC/85 %RH and, under most storage conditions, allows
for PCB soldering without any material concern about solder
joint quality due to aging of the sensor terminals, which
minimizes the concern about aging of the terminals prior
PCB assembly. Pressure choices allow engineers to select
range required for their application. Leadless SMT, SMT, and
DIP package options.
• Cost-effective: Small size helps engineers reduce design
and manufacturing costs while maintaining enhanced
performance and reliability of the systems they design.
• Accurate: Total Error Band (TEB) and wide pressure range
enable engineers to optimize system performance by
FEATURES
• Measure gage and differential pressures
• Total Error Band (see Figure 1): ±1.5 %FSS
• Liquid media option: Allows for wet/wet operation on dual
ported devices
• Industry-leading long-term stability: ±0.25 %FSS
• Industry-leading accuracy: ±0.25 %FSS BFSL
• Wide pressure range: 60 mbar to 10 bar | 6 kPa to 1 MPa |
1 psi to 150 psi
• As small as 8 mm x 7 mm
• High burst pressures (see Table 7)
• Calibrated over temperature range of 0°C to 50°C [32°F to 122°F]
• Operates from a single power supply of either 3.3 Vdc or 5.0 Vdc
• Output: Ratiometric analog or I
2
C- or SPI-compatible 12-bit
digital
• Power consumption: 2 uA typical when utilizing sleep mode option
• Meet IPC/JEDEC J-STD-020D.1 Moisture Sensitivity Level 1
requirements
• REACH and RoHS compliant
• Options: Internal diagnostic function, liquid media, sleep
mode, temperature output
POTENTIAL APPLICATIONS
Medical:
CPAP, blood analysis, blood pressure monitoring,
breast pumps, drug dosing, hospital beds, massage
machines, oxygen concentrators, patient monitoring, sleep
apnea equipment, urine analyzers, ventilators/portable
ventilators, and wound therapy
Industrial:
Air brakes, HVAC/transmitters, life sciences,
material handling, pneumatic control and regulation,
process gas monitoring, and valve positioning/positioners
Commercial:
Air beds, coffee makers, and washing
machines
PORTFOLIO
The Basic ABP Series is an addition to the following portfolio
of board mount pressure sensors: Basic NBP Series, Basic
TBP Series, TruStability™ HSC Series, TruStability™ SSC
Series, TruStability™ TSC Series, and TruStability™ NSC Series.
Sensing and Internet of Things
Detailed explanation of MSP430F5529 system working mode
[size=4][color=#8b0000]We will talk about the CPU working mode and how to control power consumption from the next level. In different working modes, the CPU will disable some modules to achieve the pu...
fish001 Microcontroller MCU
Quick Facts
ABS stands for "Anti-Lock Brake System". In the absence of ABS, emergency braking will cause the tires to lock, the braking distance will be longer, and it is easy to run off the track or drift. ABS c...
frozenviolet Automotive Electronics
Problems with using IAR5.1
I would like to ask you about IAR5.1, for example, for the flags defined in the header file of IE1, now I can't directly select and use go to definition?...
hhuchangcan Microcontroller MCU
EEWORLD University ---- TI-RSLK Module 8 - Connecting Inputs and Outputs
TI-RSLK Module 8 - Connecting Inputs and Outputs : https://training.eeworld.com.cn/course/4667...
hi5 Talking
How to control relay with infrared switch
I want to use an infrared beam switch to control the Omron MY2NJ relay. See the picture for the model of the beam switch. I connected the yellow wire to the relay, but the relay did not work. The rela...
olive85 Industrial Control Electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1843  348  2282  1152  2610  38  7  46  24  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号