断路器 Magnetic and Hydraulic-Magnetic Circuit Breaker 1P, ON-OFF, DC Long Delay, Toggle Actuator
CategoryCircuit protection    Circuit breakers and accessories    The circuit breaker   
File Size700KB,11 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Environmental Compliance
Download Datasheet Parametric Compare View All

8345-X01A-V3T1-DB1B2BX8345S01KW102M100AV Online Shopping

Suppliers Part Number Price MOQ In stock  
8345-X01A-V3T1-DB1B2BX8345S01KW102M100AV - - View Buy Now

8345-X01A-V3T1-DB1B2BX8345S01KW102M100AV Overview

断路器 Magnetic and Hydraulic-Magnetic Circuit Breaker 1P, ON-OFF, DC Long Delay, Toggle Actuator

8345-X01A-V3T1-DB1B2BX8345S01KW102M100AV Parametric

Parameter NameAttribute value
MakerE-T-A [E-T-A Circuit Breakers]
Product Categorybreaker
Shipping restrictionsMouser does not currently sell this product.
series8345
productMagnetic & Hydraulic Magnetic Circuit Breakers
Voltage ratingAC277 VAC
Voltage ratingDC80 VDC
Number of poles1 Pole
Actuator typeLever
Minimum operating temperature- 40 C
Maximum operating temperature+ 85 C
illuminationNot Illuminated
Termination typeThreaded Stud
Installation styleScrew
Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-...
Description
Single or multipole hydraulic-magnetic circuit breakers with trip-free-
mechanism and toggle actuation. A choice of switching characteristics
ensures suitability for a wide range of applications. Industry standard
dimensions and panel mounting. Auxiliary contacts optional. Low
temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934) S-type HM CBE.
Typical applications
In the business fields Communication and Transport: power supplies,
switchgear, instrumentation and process control engineering.
1-pole
Standard current ratings and typical internal resistance values
Current
rating (A)
0,05
0,1
1
2
3
5
10
15
20
25
30
40
50
60
80
100
125
Trip curves and internal resistance (Ω) per pole
F1
---
---
0,578
0,144
0,0644
0,0250
0,00901
0,00597
0,00468
0,00410
0,00385
0,00371
0,00358
---
---
---
---
---
---
0,347
0,0959
0,0477
0,0192
0,00714
0,00483
0,00410
0,00385
0,00371
0,00371
0,00358
---
---
---
---
F2
K1, M1, T1
531
129
1,10
0,295
0,121
0,0437
0,0147
0,00794
0,00597
0,00456
0,00458
0,00373
0,00335
0,00333
0,00325
0,00316
0,00314
K2, M2, T2
542
127
1,08
0,291
0,118
0,0449
0,0133
0,00794
0,00597
0,00456
0,00458
0,00373
0,00335
0,00333
0,00325
0,00316
0,00314
8345
1
2-pole
Technical data
Voltage rating
3 AC 415 V; AC 277/480 V;
AC 120/240 V; AC 240 V; DC 80 V
(higher DC voltages to special order)
0.02...125 A single and multipole
higher ratings upon request
AC 240 V 6 A
DC 28 V 3 A
DC 65 V 1 A
DC 80 V 0.5 A
10,000 operations at 1 x I
N
-40...+85 °C (-40...+185 °F)
2.5 kV/2
reinforced insulation in operating area
test
test
test
test
test
voltage
voltage
voltage
voltage
voltage
AC
AC
AC
AC
AC
3,000
1,500
1,500
3,000
1,500
V
V
V
V
V
Current rating range
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664)
Dielectric strength
operating area
Line to Load
pole to pole
(2- and 3-pole)
main to auxiliary circuit
switching to trip circuit
(version -X)
Insulation resistance
Degree of protection
(IEC 60529)
Vibration
mounting attitude
toggle down:
other mounting attitudes:
with curves F1, F2:
> 100 MΩ (DC 500 V)
operating area IP40
terminal area IP00
10 g (57-2000 Hz) ± 0,76 mm (10-57 Hz)
at 0.9 x I
N
10 g at 1 x I
N
10 g at 0.8 x I
N
in all mounting attitudes
(57-2000 Hz) ± 0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
100 g (11 ms) at 1 x I
N
,
100 g (11 ms) at 0.8 x I
N
,
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 90 - 120 g per pole
depending on version
Interrupting capacity
to EN 60934, CCC, UL 489, UL 1077
IEC 60934 / CCC (3-pole) – test series E:
voltage
DC 80 V
AC 240/415 V
AC 240 V
voltage
DC 80 V
AC 120 V
AC 120/240 V
AC 240 V
voltage
DC 80 V
AC 277/480 V
number of
poles
1+2
1–4
1
number of
poles
1+2
1
1 (2)
1
UL 1077:
number of
poles
1+2
1–4
I
N
max. (A)
0.02...125
0.02...70
I
cn
(A)
10 000
5 000
I
N
max. (A)
0.02...125
0.016...80
0.016...20
I
N
max. (A)
0.5...125
0.5...80
0.5...80
0.5...20
I
cn
(A)
10 000
6 x I
N
5 000
I
cn
(A)
10 000
5 000
5 000
5 000
Shock
directions 1, 2, 3, 4, 5:
direction 6:
with curves F1, F2:
Corrosion
Humidity
Mass
UL 489 – test sequence Z:
1843
www.e-t-a.de
1

8345-X01A-V3T1-DB1B2BX8345S01KW102M100AV Related Products

8345-X01A-V3T1-DB1B2BX8345S01KW102M100AV 8345-B07B V3Q0-DB1B2B-X8345-F01X12402M-125A 8345-F01A-R0M1-DB1B2B-80A 8345-FRS004-30A
Description 断路器 Magnetic and Hydraulic-Magnetic Circuit Breaker 1P, ON-OFF, DC Long Delay, Toggle Actuator breaker breaker breaker
Maker E-T-A [E-T-A Circuit Breakers] E-T-A [E-T-A Circuit Breakers] E-T-A [E-T-A Circuit Breakers] E-T-A [E-T-A Circuit Breakers]
Product Category breaker breaker breaker breaker
series 8345 8345 8345 8345
product Magnetic & Hydraulic Magnetic Circuit Breakers Hydraulic Magnetic Circuit Breakers Hydraulic Magnetic Circuit Breakers -
Actuator type Lever Lever Lever -
Minimum operating temperature - 40 C - 40 C - 40 C -
Maximum operating temperature + 85 C + 85 C + 85 C -
illumination Not Illuminated Not Illuminated Not Illuminated -
Termination type Threaded Stud Threaded Stud Round Terminals -
Installation style Screw Flange Flange -

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1670  2759  2313  556  2329  34  56  47  12  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号