Part Number

Search

SPS-21T-250

Description
Wire Gauge - AWG: 18~22 Plating Thickness: - Wire Gauge - mm²: 0.3~0.75 Product Type: Quick Connect Terminal Certification: RoHS
CategoryThe connector    Connector bracket   
File Size201KB,9 Pages
ManufacturerJST
Environmental Compliance
Download Datasheet Parametric Compare View All

SPS-21T-250 Overview

Wire Gauge - AWG: 18~22 Plating Thickness: - Wire Gauge - mm²: 0.3~0.75 Product Type: Quick Connect Terminal Certification: RoHS

SPS-21T-250 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresCONTACT FINISH: TIN
CertificationCSA; TUV; UL
Assembly nameCONTACT
Maximum number of cable entries0.122 inch
Minimum cable entry0.059 inch
Connector bracket typeCONNECTOR ACCESSORY
Contact point genderFEMALE
Contact resistance6 mΩ
DIN complianceNO
IEC complianceNO
MIL complianceNO
MaterialBRASS
Installation methodSTRAIGHT
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
Rated current25 A
Rated voltage (AC)250 V
Rated voltage (DC)250 V
Terminal length0.291 inch
Terminal typeCRIMP
used forPS CONNECTOR
Maximum wire diameter18 AWG
Minimum wire diameter22 AWG
Base Number Matches1
PS
CONNECTOR
Connectors for tabs
• Secure locking, easy insertion
• Stable contact performance
• Mis-insertion prevention mechanism and
housing lance
• Tab mis-mating prevention mechanism
(Short housing type)
• The product compatible with glow wire is
also available for short housing type.
Specifications –––––––––––––––––––
• Current rating: 25 A AC, DC (#250 Tab /AWG #10)
• Voltage rating: 250 V AC, DC
• Temperature range:
-
40˚C to
+
105˚C
(including temperature rise in applying
electrical current)
• Contact resistance: Initial value/ 3 mΩ max.
After environmental tests/ 6 mΩ max.
• Insulation resistance: 1,000 MΩ min.
• Withstanding voltage: 2,000 VAC/minute
• Applicable wire:
#110...AWG #24 to #16 #187...AWG #26 to #14
#205...AWG #22 to #14
#250...AWG #22 to #10
Standards ––––––––––––––––––––
1
Certified LR20812
2
R9850196
Contact
#110 Series
SPS-01T-110
3.7
0
Recognized E60389
• Applicable Tab: #110 Tab 0.5 mm thick
#187 Tab 0.5 mm/ 0.8 mm thick
#205 Tab 0.5 mm/ 0.8 mm thick
#250 Tab 0.8 mm thick
* Contact JST when you use the glow wire correspondence
product of PS-250-G (Short housing type).
* Refer to "General Instruction and Notice when using
Terminals and Connectors" at the end of this catalog.
* Contact JST for details.
* Compliant with RoHS.
SPS-41T-110
3.7
17.2
5.7
17.2
5.7
1.75
6
2.5
1.75
2.5
6
1.8
#187 Series
SPS-01T-187
(for 0.5 mm thick tabs)
SPS-51T-187
(for 0.5 mm thick tabs)
1.8
SPS-82T-187
(for 0.5 mm thick tabs)
5.6
17.2
0.9
6.4
2.5
6
1.5
0.9
6.4
5.6
17.2
6.1
2.5
1.6
0.8
6.4
5.6
18.8
7.7
3.2
1.7
2.2
2.2
2.2
SPS-01T-187-8
(for 0.8 mm thick tabs)
SPS-51T-187-8
(for 0.8 mm thick tabs)
<Flag type>
SFPS-41T-187
(for 0.5 mm thick tabs)
6.8
SFPS-41T-187-8
(for 0.8 mm thick tabs)
6.8
5.6
5.6
17.2
0.9
6.4
2.5
6.2
1.5
0.9
6.4
17.2
6.1
7.6
2.5
1.6
8
6.3
6.3
2.2
2.2
13.9
1
14.7
1
8
7.6
13.9
14.7
1

SPS-21T-250 Related Products

SPS-21T-250 SPS-01T-110 SFPS-41T-187-8 SPS-91T-250 PS-187 PS-250
Description Wire Gauge - AWG: 18~22 Plating Thickness: - Wire Gauge - mm²: 0.3~0.75 Product Type: Quick Connect Terminal Certification: RoHS Wire Gauge - AWG: 20~24 Plating Thickness: - Wire Gauge - mm²: 0.21~0.5 Product Type: Quick Connect Terminal Certification: RoHS Wire Gauge - AWG: 16~22 Plating Thickness: - Wire Gauge - mm²: 0.3~1.31 Product Type: Quick Connect Terminal Certification: RoHS Wire Gauge - AWG: 10~14 Plating Thickness: - Wire Gauge - mm²: 2~5.5 Product Type: Quick Connect Terminal Certification: RoHS Number of needles: 1 Number of rows: 1 Series: - Male and female: - Spacing: - Row spacing: - Number of needles: 1 Number of rows: 1 Series: - Male and female: - Spacing: - Row spacing: -
Several common types of pressure sensors
Pressure sensors are a very common type of sensor in industrial production and have certain applications in many fields. There are also many types of pressure sensors. Let's take a closer look.  1. Ce...
wxhxkj Sensor
Choose LED tubes and light sources from nine aspects
[hide]As a consumer, you should still be calm when choosing LEDs, make scientific analysis, and choose the light source and lamps with the best cost-effectiveness. Here are some basic properties of LE...
探路者 LED Zone
QLCE problem: An error occurred while parsing the query. [Token line number = 1,Token line offset = 15,Token in error =
int a, b; a = dataGrid1.CurrentCell.ColumnNumber; b = dataGrid1.CurrentCell.RowNumber; dataGrid1[b, a] = textBox1.Text; SqlCeConnection conn = new SqlCeConnection("Data Source=Test.sdf"); conn. Open()...
13692816588 Embedded System
Level conversion problem
Remove R12 from the figure, and the voltage at the red arrow is 0V when there is a signal input at IN, and 5V when there is no signal input. The circuit is normal. When R12 is connected, the voltage a...
qrnuyangfu Analog electronics
Looking for experts to develop Ethernet/IP slaves
[p=26, null, left][color=rgb(17, 17, 17)][font=XinGothic-SinaWeibo,][b]1. Proficient in Ethernet/IP protocol, practical Ethernet/IP project experience, preferably with mature products. [/b][/font][/co...
靠山王1023 Recruitment
Problems with complex.h in C6000
In complex.h, why do I always get incorrect results when I use the functions defined therein: _Fcomplex (_FCmulcc)(_Fcomplex, _Fcomplex); _Fcomplex (_FCaddcc)(_Fcomplex, _Fcomplex); _Fcomplex (_FCsubc...
chhtx DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2389  2101  74  2360  292  49  43  2  48  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号