EEWORLDEEWORLDEEWORLD

Part Number

Search

PM337CE

Description
Single, dual and triple output 2.5 to 15 Watt AC/DC encapsulated modules
File Size39KB,2 Pages
ManufacturerArtesyn
Websitehttp://www.artesyn.com
Download Datasheet View All

PM337CE Overview

Single, dual and triple output 2.5 to 15 Watt AC/DC encapsulated modules

PM337CE Preview

PM300CE SERIES
Single, dual and triple output
Encapsulated package
2.5 to 15W modules
230VAC input (115VAC version, see PM300 series)
Chassis mounting inserts
Terminal strip connections
Short circuit protection
EN55022, EN55011 conducted emissions level B
EN61000-4-2, -3, -4, -5, -6 compliant
Meets EN60950
[ 2 YEAR WARRANTY ]
The PM300CE series is an encapsulated, chassis mountable linear AC/DC power
module with the CE mark to demonstrate compliance with the Low Voltage Directive
for European applications. The series has single, dual and triple output models with
industry standard output configurations operating from an input voltage of 230VAC
making the PM300CE series suitable for a wide range of low power chassis
applications. The PM300CE series includes 2.5W to 15W modules. Each module has
short-circuit protection and the 5V outputs also have overvoltage protection.
Conservative design and rating of these modules results in reliable operation and long
life. There are four threaded inserts in the bottom of each module for convenient
chassis mounting. The PM300CE design is a low emissions design with tightly
regulated outputs making the series especially suitable for test, measurement and
instrumentation equipment.
SPECIFICATION
OUTPUT SPECIFICATIONS
Voltage accuracy
Line regulation
Load regulation
Temperature coefficient
Overvoltage protection
(See Note 4)
Output power limit
Short circuit protection
INPUT SPECIFICATIONS
Input voltage range
Input frequency range
Safety ground leakage
current
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
EMC CHARACTERISTICS
±1.0%, max.
See table on
facing page
See table on
facing page
±0.02%/°C
GENERAL SPECIFICATIONS
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022
EN55022
EN61000-4-2,
EN61000-4-2,
EN61000-4-5,
EN61000-4-4,
EN61000-4-3,
EN61000-4-6,
Level B
Level B
criteria 1
criteria 1
criteria 1
criteria 1
criteria 1
criteria 1
level
level
level
level
level
level
3
4
3
3
3
3
Perf.
Perf.
Perf.
Perf.
Perf.
Perf.
5V outputs only
6.2V typical
Efficiency
130% to 200% FL typ.
100% to 200% FL
Isolation voltage
Isolation capacitance
Approvals and
standards (See Note 5)
230VAC ±10%
Case material
UL94V-0
Case C1
Case C2
47Hz to 400Hz
<3.5mA @ 50Hz
Weight
MTBF (See Note 3)
ENVIRONMENTAL SPECIFICATIONS
Temperature
Operating ambient
–25°C to +71°C
Non-operating amb. –25°C to +71°C
Derating, 50°C to 71°C
2.5%/°C
Cooling
Free-air convection
cooled
Non-condensing
20% to 95% RH
40% typical
3000VAC
50pF
Meets EN60950
Non-conductive
black plastic
567g (20.02oz)
816g (28.80oz)
710,000 hours
(See Note 2)
Relative Humidity
PAGE 1
ENCAPSULATED LINEAR AC/DC POWER SUPPLIES
|
2.5-15W AC
2.5 to 15 Watt
AC/DC encapsulated modules
OUTPUT
VOLTAGE
OUTPUT
CURRENT
OVP
(4)
REGULATION
LINE
LOAD
SINGLE OUTPUT
RIPPLE AND
NOISE
CASE
AVAILABLE MODELS
5VDC
5VDC
5VDC
500mA
1000mA
2000mA
Yes
Yes
Yes
±.05%
±.05%
±.05%
±0.10%
±0.15%
±0.15%
DUAL OUTPUT
2mV rms
2mV rms
2mV rms
C1
C1
C2
PM334CE
PM342CE
PM345CE
±12VDC
±12VDC
±15VDC
±15VDC
±15VDC
±15VDC
±240mA
±400mA
±100mA
±200mA
±350mA
±500mA
No
No
No
No
No
No
±0.05%
±0.05%
±0.05%
±0.05%
±0.05%
±0.05%
±0.05%
±0.05%
±0.05%
±0.05%
±0.05%
±0.05%
TRIPLE OUTPUT
(1)
1mV rms
1mV rms
1mV rms
1mV rms
1mV rms
1mV rms
C1
C2
C1
C1
C2
C2
PM337CE
PM397CE
PM302CE
PM365CE
PM301CE
PM396CE
5V/±12VDC
5V/±15VDC
5V/±15VDC
5V/±12VDC
Note
1
2
3
4
5
500/±120mA
500/±100mA
1000/±150mA
1000/±150mA
Yes
Yes
Yes
Yes
±0.05%
±0.05%
±0.20%
±0.20%
±0.1%/±0.05%
±0.1%/±0.05%
±0.1%/±0.02%
±0.1%/±0.02%
1mV rms
1mV rms
1.0/0.5mV rms
1.0/0.5mV rms
C1
C1
C2
C2
PM391CE
PM390CE
PM393CE
PM392CE
Triple output models only: the 5V output common is isolated from the
±12VDC or ±15VDC common.
Some units should be derated for operation at 400Hz. Please contact the
factory for details.
M.T.B.F. figures are based on actual product performance. Consult factory
for details.
Triple output models only: overvoltage protection is only available on the
5V outputs.
All models are only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
CASE C
0.75
(19.1)
0.75
(19.1)
5.40 BH
Screws
Single
Output
Models
Dual
Output
Models
Triple
Output
Models
AC
AC
AC
NC
AC
AC
NC
– OUT
COM
+ OUT
COM
+ 12V OUT
+ 15V OUT
AC
– 5V OUT
+ 5V OUT
– 12V OUT
– 15V OUT
INSERTS
4.40 THREAD
0.125 (3.2) DEEP
2.50
(63.5)
4.00
(101.6)
NC
COM
+ OUT
C1 C2
1.45
(36.8)
2.00
(50.8)
2.00
(50.8)
2.70
(68.6)
0.35
(8.9)
ALL DIMENSIONS IN INCHES (mm)
DS_PM300CE_19980401.PDF
Data Sheet © Artesyn Technologies® 2000
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
http://www.artesyn.com
PAGE 2
The design of the DSP development board seems to have problems, and the AD acquisition fluctuates greatly. I hope an expert can take a look.
I designed my own board with reference to the Ti development board. When testing the AD module, the fluctuation was very large and it could not be used. The analog ground and digital ground of the boa...
工学9号 DSP and ARM Processors
"ADI Analog University" 2013 Year-round Data Collection
[i=s]This post was last edited by chen8710 on 2014-3-11 15:48[/i] [size=6][color=#4b0082]"ADI Simulation University" 2013 Full Year Information Collection[/color][/size][size=6][color=#4b0082] [/color...
chen8710 ADI Reference Circuit
Siemens S7-300 150 Questions Answered Part 3 (Reprinted)
41: What should be noted when making direct access to I/O?   It should be noted that in an S7-300 configuration, if direct read access to I/O across modules is made (using this command to read several...
bianpinqi Industrial Control Electronics
【Share your experience】-- Characteristics and applications of STM32F0xx ADC
Characteristics and applications of STM32F0xx ADC Characteristics and applications of STM32F0xx ADC The ADC of STM32F0xx is a successive approximation type, 12 bits, with the fastest conversion time o...
dontium stm32/stm8
Not displayed Delete Reply Display Please help me! There is a problem with stdio.h
I use keil uv3 programming, and #include a stdio.h mainly for using printf. It worked before, but it doesn't work these days. I didn't make any wrong operation. The compile-time error message is as fo...
eeleader MCU
TCP communication problem
I'm begging for help... My ECV data transmission program under TCP protocol will disconnect when the client receives something (the server fails to send and prompts error 10054). The server program ca...
zuigui111 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1361  2741  1061  2409  536  28  56  22  49  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号