EEWORLDEEWORLDEEWORLD

Part Number

Search

1600HG3G01P1EGA

Description
Strain Guage Sensor, Gage, -15Psi Min, 285Psi Max, 0.5%, 1-5V, Cylindrical,
CategoryThe sensor    Sensor/transducer   
File Size423KB,3 Pages
ManufacturerGems Sensors & Controls
Download Datasheet Parametric View All

1600HG3G01P1EGA Overview

Strain Guage Sensor, Gage, -15Psi Min, 285Psi Max, 0.5%, 1-5V, Cylindrical,

1600HG3G01P1EGA Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Reach Compliance Codecompliant
Maximum accuracy(%)0.5%
body height53.2 mm
Body length or diameter27.3 mm
shellSTAINLESS STEEL
Nominal offset1V
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range1-5V
Output typeANALOG VOLTAGE
Package Shape/FormCYLINDRICAL
port type9/16-18 EXTERNAL
Maximum pressure range285 Psi
Minimum pressure range-15 Psi
Pressure sensing modeGAGE
Response time500 µs
Sensor/Transducer TypePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage35 V
Minimum supply voltage1.5 V
Termination typeCABLE
Base Number Matches1
PSIBAR® CVD TYPES
Gauge, Vacuum, and Compound Pressure Models
General Purpose and Wash down Enclosures
High Proof Pressure Achieved by Thicker Diaphragm Construction
Voltage and Current Output Models
The 1200 Series features stability and toughness via its CVD and ASIC design coupled
with a thicker diaphragm. The thicker diaphragm enables these sensors to survive
most pressure spikes caused by pump ripple, solenoid valves, etc. The 1600 Series
extends the packaging options by providing an all welded stainless steel back end
for demanding industrial applications. A modular design allows special ordering of
fittings, electrical cables, etc. for OEM applications. The ASIC and CVD technology
enables Gems to offer almost any output over any pressure range.
Specifications
Input
Pressure Range
Proof Pressure
Burst Pressure
Fatigue Life
Performance
Supply Voltage Sensitivity
Long Term Drift
Accuracy
Thermal Error
Compensated Temperatures
Operating Temperatures
Vacuum to 400 bar (6000 psi)
4 x Full Scale (FS) (<1% FS Zero Shift)
>35 x FS <= 4 bar (60 psi);
>20 x FS <=40 bar (600 psi);
>5 x FS <= 400 bar (6000 psi)
Designed for more than 100 million FS cycles
0.01% FS/Volt
0.2% FS/year (non-cumulative)
0.5% FS typical
2.0% FS typical
-20°C to 80°C (-5°F to 180°F)
-40°C to 125°C (-40°F to 260°F) for elec. codes A, B, C, 1
-20°C to 80°C (-5°F to 180°F) for elec. codes 2, D, G, 3
-20°C to 50°C (-5°F to 125°F) for elec. code F
temperatures >100°C supply is limited to 24 VDC
1% of span
1% of span
0.5 ms
see ordering chart
17-4 PH Stainless Steel
see ordering chart
316 SS, 17-4 PH ss
IP65 NEMA 4 for elec. codes A,B,C,D,G,1,2,3
IP67 for elec. codes F
IP30 for elec. code “3” with flying leads
70g, peak to peak sinusoidal, 5 to 2000 Hz
(Random Vibration: 20 to 200 Hz @
20g
Peak
per MIL-STD.-810E Method 514.4)
100g steady acceleration in any direction 0.032% FS/g
for 1 bar (15 psi) range decreasing logarithmically
to 0.0007% FS/g for 400 bar (6000 psi) range.
20g, 11 ms, per MIL-STD.-810E Method 516.4 Procedure I
CE, UR (12 ET, 16 ET Intrinsically safe)
approx. 100 grams (additional; cable 75 g/m)
Along with the superiority of the CVD strain gauge,
Psibar
®
transducers incorporate components to
leverage the sensing element’s strength. The output is
a product with a unique balance of performance and
value unmatched in today’s pressure sensing market.
Thicker diaphragm for handling
pulsating pressures –
all stainless steel wetted parts.
CVD sensor stability and high
sensitivity allows use of our
thicker diaphragm. 17-4 PH SS
sensor beam is laser welded for
distortion-free construction.
Weldless
stainless steel
case.
Zero Tolerance
Span Tolerance
Response Time
Mechanical Configuration
Pressure Port
Wetted Parts
Electrical Connection
Enclosure
ASIC chip is the brains
behind the brawn.
Programmability provides
greater linearity correction
than common thermal
compensation methods.
RFI/EMI & ESD protection circuit
meets and exceeds requirements for
CE marking. Protecting against noise,
voltage spikes and static discharge.
Vibration
Acceleration
Shock
Approvals
Weight
www.gemssensors.com
G-7
PRESSURE TRANSDUCERS
1200 Series / 1600 Series –
OEM Transducers Featuring Exceptional
Proof Pressure and Stability Specifications
Recently, my boss has paid special attention to the program protection of laser equipment. Do you have any good methods?
Recently, my boss has been paying special attention to the program protection of laser equipment. Do you have any good methods to recommend?...
UP798 Embedded System
Xiao Meige will study FPGA digital tube dynamic scanning with you in depth
In electronic systems, output devices are usually required to output or display certain information to indicate the current operating status of the system. In electronic systems based on single-chip m...
小梅哥 FPGA/CPLD
What is the meaning of RAMIMAGE?
RAMIMAGE is said to be a place for OS. I think when starting OS, NK.bin should be first decompressed into a block like NK.nb0. I want to know whether RAMIMAGE is the first address of NK.bin or the fir...
mn14174 Embedded System
SensorTile.box firmware update
1. Material preparation Download collection: https://bbs.eeworld.com.cn/thread-1105280-1-1.html At present, the only information that can be downloaded seems to be here. In addition, there is a develo...
tinnu ST MEMS Sensor Creative Design Competition
What is the essential difference between PLC and RTU?
The remote module was originally designed for use in control rooms, so it has poor adaptability to harsh environments. Compared with remote modules, RTU has powerful communication functions and integr...
eeleader-mcu Industrial Control Electronics
Newbies make progress together - Renesas driver and firmware update
[i=s] This post was last edited by 不足论 on 2014-8-2 23:18 [/i] I read a lot of posts from great people today, but I feel that they skipped a lot of things. For those of us who have just started to lear...
不足论 Renesas Electronics MCUs

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1967  2064  1746  1901  305  40  42  36  39  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号