EEWORLDEEWORLDEEWORLD

Part Number

Search

IA-3000

Description
Hall Effect Sensor, Rectangular, Panel Mount
CategoryThe sensor    Sensor/transducer   
File Size636KB,2 Pages
ManufacturerTektronix
Websitehttps://www.tek.com/
Download Datasheet Parametric Compare View All

IA-3000 Overview

Hall Effect Sensor, Rectangular, Panel Mount

IA-3000 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
body width88.9 mm
body height139.7 mm
Body length or diameter114.3 mm
Linearity(%)0.6 %
Installation featuresPANEL MOUNT
Maximum working current50 mA
Maximum operating temperature75 °C
Minimum operating temperature-30 °C
Package Shape/FormRECTANGULAR
Sensor/Transducer TypeMAGNETIC FIELD SENSOR,HALL EFFECT
surface mountNO
Base Number Matches1
IA-100, 250, 500,1000, 2000, 3000
Open Loop Hall Effect
Current
Sensors
Description
The IA Series Hall effect current sensors accurately measure dc
and ac currents and provide electrical isolation between the
output of the sensor and the current carrying conductor.
• High accuracy
• Wide frequency range
• Excellent linearity
• Safety isolation
• DC current measurement
• Heavy duty housing
Features
Applications
• Motor controllers and drives
• Battery supplied equipment
• Switch mode and uninterruptable power supplies
• Welding equipment
• Traction sensing
Measuring Circuit
Units
IA-100
100
IA-250
250
IA-500 IA-1000 IA-2000 IA-3000
500
1000
2000
3000
Full Scale (FS) dc or ac peak ............ + A
Full Scale output ............................ + V
Frequency range ............................
Response time (1) .......................... µs
10
dc (permissible ripple content <200 A rms at 360 Hz)
<150
Excitation Circui t
Supply voltage ............................... + Vdc
Max. positive supply current ............ mA
Max. negative supply current .......... mA
15
50
10
Output
Sensitivity ......................................
Linearity ........................................
Calibration point (2) .......................
Typical zero current offset ..............
Maximum zero current offset ..........
Maximum hysteresis of offset (3) ....
Minimum load resistance ..............
mV/A
+ % FS
+ %RDG
+ mV
+ mV
+ mV
k ohms
100
0.5
40
0.5
20
0.5
0.5
10
50
>2
10
0.5
5
0.5
3.3
0.6
200
100
50
25
15
15
Influences On Accuracy
Typical offset drift with temp ...........
Max. offset drift with temp................
Excitation change of + 1%
Max. sensitivity change....................
Typical sensitivity drift with temp
......
Max. sensitivity drift with temp
........
+
mV/ C
o
+
mV/ C
+ %
o
+ %/ C
o
+ %/ C
o
1
2
0.03
0.015
0.02
Withstand Capabilities
Dielectric test (4) ........................... kV
Output short or open
...................
2.5
No Damage
General Information
Operating temperature range ....
......
o
C
-30 to +75
o
Storage temperature range ............ C
-40 to +85
Package ........................................
rugged metal case
Aperture opening .......................... in. (mm)
1.67 (42.4)
Weight ......................................... Lbs.(grams)
5 Lbs. 10 oz. (2.6 kg)
Mounting ..................................... F ive mounting holes 0.281 inch (7.1 mm) diameter on steel base plate
Output reference ...........................
To obtain a positive output on the terminal marked “+Vo”, positive conventional
current must flow as per the direction of the arrow marked on the sensor.
6120 Hanging Moss Road • Orlando, Florida 32807 •
www.fwbell.com
Phone (407) 678-6900 • Fax (407) 677-5765 • Toll Free (800) 778-6117
Rev. date 04/2003

IA-3000 Related Products

IA-3000 IA-2000 IA-100
Description Hall Effect Sensor, Rectangular, Panel Mount Hall Effect Sensor, Rectangular, Panel Mount Hall Effect Sensor, Rectangular, Panel Mount
Reach Compliance Code unknown unknown unknown
body width 88.9 mm 88.9 mm 88.9 mm
body height 139.7 mm 139.7 mm 139.7 mm
Body length or diameter 114.3 mm 114.3 mm 114.3 mm
Linearity(%) 0.6 % 0.5 % 0.5 %
Installation features PANEL MOUNT PANEL MOUNT PANEL MOUNT
Maximum working current 50 mA 50 mA 50 mA
Maximum operating temperature 75 °C 75 °C 75 °C
Minimum operating temperature -30 °C -30 °C -30 °C
Package Shape/Form RECTANGULAR RECTANGULAR RECTANGULAR
Sensor/Transducer Type MAGNETIC FIELD SENSOR,HALL EFFECT MAGNETIC FIELD SENSOR,HALL EFFECT MAGNETIC FIELD SENSOR,HALL EFFECT
surface mount NO NO NO
Base Number Matches 1 1 -
Maker - Tektronix Tektronix

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 111  1643  241  198  218  3  34  5  4  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号