Description
400W AC-DC ACTIVE PFC MEDICAL POWER SUPPLY
File Size248KB,2 Pages
ManufacturerMicroPower Direct ( MPD )
Websitehttp://www.micropowerdirect.com
Download Datasheet Compare View All

MPA400Mxy-48z Overview

400W AC-DC ACTIVE PFC MEDICAL POWER SUPPLY

MicroPower Direct
Go Direct -
MicroPower Direct
- For Product, Performance and Price
400W AC-DC ACTIVE PFC MEDICAL POWER SUPPLY
MPA400M SINGLE OUTPUT SERIES
FEATURES:
U - Chassis Type: 8 x 5 x 1.6”
Enclosed with built-in fan Type: 9 x 5 x 1.6”
Medical Safety Approvals
Optional N+1 Forced Active Current Sharing
Power Factor Corrected to EN61000-3-2 class D
Providing Peak Power 700W within 500uS duty duration
U-Chassis & Enclosed with built-in fan Mechanical Options
1U height size and High power density: 6.25 watts/cu inches
Current Monitoring and Remote Voltage adjustment (Margin)
PRODUCT SPECIFICATIONS:
Input Voltage:
90-264 Vac full range, 47~63 Hz.
Input Current:
6.35A at 90VAC full load.
Inrush Current:
35A Max @ 230 Vac with full load and cold start.
PFC:
Active power factor correction meet EN61000-3-2 class D.
Fan Drive:
12VDC/400mA is available to drive an external fan.
Transient Response:
Returns to within 1% in less than 2.5 mS for
a 50% load change and the peak transient does not excess 5%.
Overshoot:
Turn-on/off not exceed 5% over nominal voltage.
Efficiency:
82% minimum (Measuring at 230V and full load).
Turn On Delay
: 1 second maximum at 120 VAC.
Hold Up Time:
20 mS min. at 80% of full load.
Adjustability:
Output user adjustable ±5% minimum.
Remote Sense:
Designated “RS+” and “RS-” on the CN3.
(Not available for current sharing models)
Remote On-Off:
Designated as “RSW” on the CN3, requires a low
signal to inhibit output.
Power Supply On:
Green LED designated as “LED 1” on the PCB.
LED display:
Bi-color “LED1” emit green light on operating. Any
protection occurred or RSW applied low signal will emit orange.
Power Good:
Designated as “PG” on the CN3 will go high 100-
500 mS after regulation and goes low 1mS before loss of regulation.
Current Sharing:
Designated as “CSH” on the CN3, optional
single wired for forced current sharing function and parallel up to 4
units within 10% accuracy at full load.
Current Monitor:
Designated as “CMN” on the CN3 for current
sense for a 0.5V to 3 VDC to represent 0% to 100% output current.
Margin:
Designated as “MGN” on the CN3 providing 50% of output
voltage remote adjustment by applying 0.4 ~ 5V signal on “MGN”.
AC Fail (optional):
Designated as “ACF” on the CN3 to monitor the
input voltage, when input goes under 80 +/- 5VAC the signal will go
low (0V) and then go high (+5V) once reappears over 86 Vac.
(Input voltage protection must be disabled when AC Fail is enable.)
Input Circuit (primary):
Two protected fuse inserted, shall be
blown only by an internal power fault.
CB
Input Voltage Protection:
Power shut down under 80 ±5 Vac,
and recovered over 86 Vac.
(Disabled unless AC Fail is requested)
Over-Power Protection:
C.C. mode 110-140% and auto-recovery.
Over-Voltage Protection:
Latching down will occur when output
voltage exceed 130% and recycle AC input to reset.
Short Circuit Protection:
Trip without damage and auto-recovery.
Over Temperature Protection:
Protected in the event of
excessive operating ambient 85°C, with automatic recovery.
Switching Frequency:
30 kHz fixed frequency.
Operating Temperature:
O to 70°C ambient, de-rating at 2.5%
per degree from 50°C to 70°C.
°
°
Storage Temperature:
-20 to 85°C.
Operating Humidity:
5% to 90% RH, Non-condensing.
Storage Humidity:
5% to 95% RH, Non-condensing.
Vibration:
Frequency 5 to 50 Hz, acceleration +/-7.35 M/(SxS) on
X,Y and Z Axis.
Emissions:
FCC Part 15, CISPR 22 class B, Conducted.
Safety Regulation:
Approved to UL60950-1/ 60601-1, CSA
C22.2 No. 60950-1-03/ 601.1-M90, TUV EN60950-1/ 60601-1, CE
Mark (LVD) EN61204-3/ 60601-1-2/ 61000-3-2,3 & IEC61000-4
Series Regulations and CB.
Leakage Current:
300uA
HI-POT Test:
1500 Vac between input line and chassis (2mA DC
cut off current); 4000 Vac between primary and secondary
windings; Primary to core 1500 VAC. All for 3 sec.
Grounding Test:
Apply 40 A from ground pin to the earthed
connection point. Maximum allowable resistance is 0.1ohm.
Warranty:
2 years.
MTBF:
100000 Hrs (according to MIL-HBK-217F) at 30
?
.
Cooling:
External forced air requires achieving full ratings.
Burn in:
45 +/- 5°C for 1 hour @ 230 Vac with full load.
Enclosure:
U-Chassis type - 8(L) x 5(W) x 1.6(H) inches.
Enclosed type - 9(L) x 5(W) x 1.6(H) inches.
Weight:
U-Chassis Type – 1.3KG; Enclosed Type – 1.6KG;
MicroPower Direct
www.micropowerdirect.com
292 Page Street, Ste D Stoughton, MA 02072
TEL:
(781) 344-8226
FAX:
(781) 344-8481
EMAIL:
sales@micropowerdirect.com

MPA400Mxy-48z Related Products

MPA400Mxy-48z MPA400M MPA400Mxy-36z
Description 400W AC-DC ACTIVE PFC MEDICAL POWER SUPPLY 400W AC-DC ACTIVE PFC MEDICAL POWER SUPPLY 400W AC-DC ACTIVE PFC MEDICAL POWER SUPPLY
; Please tell me, CR EQU 13
I would like to ask about a 51 assembly program: $ep CR EQU 13 LF EQU 10 PUBLIC START SAMP SEGMENT CODE ;ssfs RSEG SAMP START: MOV SCON, #52H MOV TCON, #0D2H MOV TH1, #13 SETB TR1 LOAD: MOV DPTR, #MSG...
huanbo0227 Embedded System
Can't see anymore (psychopathic joke)
A doctor in a mental hospital asked a patient: What would happen if I cut off one of your ears? The patient replied: I would not be able to hear. The doctor listened and said: Yes, that's normal. The ...
shuangshumei Talking
ISPlay v1.5
ISPlay v1.5 (2005.3.12) Loading device library completed! Failed to initialize parallel port! What's the problem?...
williams Embedded System
EEWORLD University ---- IoT Moment: Protocol Standards Driving the Development of IoT
IoT Moment: Protocol Standards Driving the Development of IoT : https://training.eeworld.com.cn/course/5079In the latest in Qorvo's "IoT Moments" series, Cees Links discusses the importance of protoco...
soso RF/Wirelessly
Looking for a professional programmer
Currently, the company needs to program an IC S29AL008D. The manufacturer is Spansion SMD packaged Flash. I wonder which programmers support this IC?...
kids Embedded System
Can I use waveout to play PCM data in WinCE6.0? What do I need to configure in the system?
As the title says, I can compile and link waveout in WinCE, but when running on the device, waveOutOpen returns 6: #define MMSYSERR_NODRIVER (MMSYSERR_BASE + 6) /* no device driver present */ It seems...
newstarce Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2815  1153  1746  943  1557  57  24  36  19  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号