Description
30-40 WATT MEDICAL POWER SUPPLIES
File Size214KB,2 Pages
ManufacturerTRUMPower
Websitehttp://www.trumpower.com/
Download Datasheet Compare View All

TM41-12 Overview

30-40 WATT MEDICAL POWER SUPPLIES

TRUMPower
D E SCR IPTION
30-40 WATT MEDICAL POWER SUPPLIES
TM41 SERIES
( LV D )
The TM41 series of compact, open PCB constructed,
AC-DC switching power supplies are capable of
delivering 30 to 40 watts of continuous output power.
They operate at 85 to 264VAC input voltage without
the need of voltage selection. They are ideally suited
for use in medical equipments, safety systems and
monitoring equipments.
RoHS
F EATU R E S
Low safety ground leakage current
100% burn-in
8 5 t o 2 6 4 VA C w i d e i n p u t r a n g e
Input surge current protection
O v e r v o l ta g e p r o t e c t i o n
Overcurrent protection
Open PCB construction
C o m p l i a n t w i t h R o H S r e q u i r e m e n ts
Saf et y Sta n da rd A ppr o va ls:
UL 2601-1
CSA C22.2 No. 601.1
IN PUT S PE C IF ICAT ION S
I n p u t v o l ta g e
Input frequency
Input current
Earth leakage current
8 5 t o 2 6 4 VA C
11 0 t o 2 8 0 V D C
47 to 63Hz
1 . 1 A
r m s
f o r 11 5 VA C
0 . 6 A
r m s
f o r 2 3 0 VA C
9 0 µ A m a x . @ 11 5 VA C , 6 0 H z
1 5 0 µ A m a x . @ 2 3 0 VA C , 5 0 H z
TÜV EN60601-1
GENERAL SPECIFICATIONS
Switching frequency:
42KHz ±5KHz
Efficiency:
70% minimum on single output
model with Vo
12V, 68%
minimum on the others
20 msec minimum at 110VAC
±0.5% maximum at full load
12 amps @ 115VAC or 24 amps
@ 230VAC, at 25ºC cold start
4000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
OUTPUT SPECIFICATIONS
Output voltage/current:
Total output power:
Ripple and noise:
Over voltage protection:
See rating chart
See rating chart
1% peak to peak max.
Provided on output; set at
112 – 132% of its nominal
output voltage
The output protected to short
circuit conditions
All outputs ±0.04%/ºC
i
Maximum excursion of 4% or
better on all models,
recovering to 1% of final value
within 500µs after a 25% step
load change
Hold-up time:
Line regulation:
Inrush current:
Withstand voltage:
Over current protection:
Temperature coefficient:
Transient response:
600,000 hours minimum at full load
at 25ºC ambient, calculated per
MIL-HDBK- 217F
EMC Performance (EN60601-1-2: 2001)
E N 5 5 0 11 :
FCC:
VCCI:
EN61000-3-2:
EN61000-3-3:
EN61000-4-2:
EN61000-4-3:
EN61000-4-4:
EN61000-4-5:
EN61000-4-6:
EN61000-4-8:
E N 6 1 0 0 0 - 4 - 11 :
Class B conducted, Class B radiated
Class B conducted, Class B radiated
Class B conducted, Class B radiated
Harmonic distortion, Class A and D
Line flicker
ESD, ±8KV air and ±6KV contact
Radiated immunity, 3V/m for 80-2500MHz
Fast transient/burst, ±2KV
Surge, ±1KV diff, ±2KV com.
Conducted immunity, 3Vrms
Magnetic field immunity, 3A/m
Voltage dips, 30% reduction for 500ms,
60% reduction for 100ms and >95%
reduction for 10ms
MTBF:
E N V IR O N M ENTA L SP E C IF ICATI O N S
Operating temperature:
Storage temperature:
Relative humidity:
Derating:
0ºC to +70ºC
-40ºC to +85ºC
5% to 95% non-condensing
Derate from 100% at +50ºC
linearly to 50% at +70ºC
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616
Fax: 408-988-6622
email: sales@trumpower.com
Website: www.TRUMPower.com

TM41-12 Related Products

TM41-12 TM41 TM41-15 TM41-5.1 TM41-28 TM41-24 TM41-18
Description 30-40 WATT MEDICAL POWER SUPPLIES 30-40 WATT MEDICAL POWER SUPPLIES 30-40 WATT MEDICAL POWER SUPPLIES 30-40 WATT MEDICAL POWER SUPPLIES 30-40 WATT MEDICAL POWER SUPPLIES 30-40 WATT MEDICAL POWER SUPPLIES 30-40 WATT MEDICAL POWER SUPPLIES
Will there be conflicts if Windows CE 5.0 and 6.0 are installed at the same time?
I want to learn Windows ce bsp development now, and I have installed 5.0 and 6.0 at the same time. Will there be any conflicts?...
tianhj2001 Embedded System
Some information about DSP parallel port emulator
Self-defense of authenticity, from the Internet, who did it, which file is OK, please tell me here. It can save you money. [[i] This post was last edited by jinpost on 2008-6-20 09:49 [/i]]...
lusongbo DSP and ARM Processors
An error encountered when compiling WinCE
WINCE420\public\common\cesysgen Creating appropriate directories and deleting COMMON.LOC NMAKE : fatal error U1077: 'echo' : return code '0x1' Stop. Microsoft (R) Program Maintenance Utility Version T...
sgyao Embedded System
stc microcontroller simulates I2C bus writing
[size=14px]I am using STC8a8k microcontroller, and want to realize EEPROM reading and writing by simulating I2C bus, but I always feel that nothing is written in, and the result of reading it through ...
nidalmahehe 51mcu
51 MCU static local variable problem>?
I just read an article on the forum titled 51 Single Chip Microcomputer Programming Skills. It said that static variables are best placed in CODE. However, if you put them in CODE and give them initia...
j1a2s3o4n 51mcu
The difference between UBRRL=(fosc/16/(baud+1))%256 and UBRRL=(fosc/16/baud-1)%256
Dear masters, I am a beginner in avr. Some of the reference programs are UBRRL=(fosc/16/(baud+1))%256, while others are UBRRL=(fosc/16/baud-1)%256. The results are also different. I hope those who kno...
jinxiang Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 725  971  1753  573  2368  15  20  36  12  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号