EEWORLDEEWORLDEEWORLD

Part Number

Search

31013203

Description
Board Connector,
CategoryThe connector    The connector   
File Size101KB,1 Pages
ManufacturerMETZ CONNECT
Websitehttp://www.metz-connect.com/
Environmental Compliance
Download Datasheet Parametric View All

31013203 Overview

Board Connector,

31013203 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerMETZ CONNECT
Reach Compliance Codecompliant
ECCN codeEAR99
Connector typeBOARD CONNECTOR
OptionsGENERAL PURPOSE
Base Number Matches1
mm to inch
1 inch = 25.4 mm
1 mm = .040 inches
Designed to IEC 60664-1
Designed to IEC 60664-1
Type
13
Additional Centerline
Type 13
Type 313
Voltage
for panel feed
thru mounting,
with rising clamp
Type
313
300 V - centerline 5 mm
600 V - centerline 10 mm
15 A
12 - 22 AWG
# (see note)
8 lbs. - in
7 mm
5 mΩ per circuit
Voltage
wire termination
on rippled side
Electrical Data
Electrical Data
300 V - centerline 5 mm
600 V - centerline 10 mm
12 A
12 - 28 AWG
4.5 lbs. - in
8 mm
10 mΩ per circuit
Headers that mate with
Type 13
Type 19
Type 29
Type 20
Type 33
Type 35
Type 30
Type 36
Type 34
Type 313
Type 270
Page H-22
Page H-22
Page H-24
Page H-23
Page H-14
Page H-18
Page H-15
Page H-16
Page H-16
Page H-19
Page H-20
Page H-20
Current
Wire range
Screw torque
Wire strip length
Contact resistance
Current
Wire range
Screw torque
Wire strip length
Contact resistance
Mechanical Data
Housing
UL 94V-0
-40 °F to 189 °F
(-40 °C to 105 °C)
brown
brass, nickel plated
berylliumcopper,
silver over nickel plating
optional: tin/gold plating
- consult factory
German silver
M3, steel,
nickel over copper plating
2 to 24 - centerline 5 mm
2 to 12 - centerline 10 mm
Mechanical Data
Housing
UL 94V-0
-40 °F to 189 °F
(-40 °C to 105 °C)
brown
brass, nickel plated
copper alloy, tin plated
M3, steel,
nickel over copper plating
2 to 24 - centerline 5 mm
2 to 12 - centerline 10 mm
Color
Terminal
Contact socket
Color
Terminal
Wire protector
Screw
Pole sizes
Wire protector
Screw
Pole sizes
D
Type 274
Type 276
Type 278
Type 280
Type 319
Type 320
Type 329
Type 330
Additional material data - pages DA-3 to DA-5
Page H-24
Page H-15
Page H-17
Page H-19
Page H-21
Additional material data - pages DA-3 to DA-5
Dimensions (mm)
Dimensions (mm)
Accessories
for
Type 13
Mounting flange
360176
Page J-3
Coding set
720254-01-6
720254-02-5 Page J-10
L = (circuits - 1) x centerline + 6.5
L = (circuits - 1) x centerline + 5
Part Numbers
Type 13
Complete the part number
by adding the pole size.
centerline 5 mm
Part Numbers
02 03 04 05 06 07 08
09 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24
02 03 04 05 06 07 08
09 10 11 12
Type 313
Complete the part number
by adding the pole size.
centerline 5 mm
Note for wire range
Additional wire sizes and/or
combinations of same size
wires as follows:
Part No.
310131
Type 13
centerline 10 mm
Part No.
313131
Type 313
centerline 10 mm
02 03 04 05 06 07 08
09 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24
02 03 04 05 06 07 08
09 10 11 12
Part No.
310132
Part No.
313132
Type 13
#
1 No. 30 AWG
(Factory-wiring)
01 standard
08 Available on demand. Minimum order
quantity 3000 poles per item.
01 standard
08 Available on demand. Minimum order
quantity 3000 poles per item.
Subject to technical changes and printing errors.
RIA electronic, Inc.
430 Industrial Way West, Eatontown, NJ 07724
phone 1-888-722-5625
fax 732-389-9066
www.riaelectronic.com
DB-10
I'm a super novice. I don't know how to deal with the compilation error. Please help me.
I just installed the software and found a program in the forum. I want to understand and familiarize myself with the software process and see if it works. :Cry: I encountered such a problem and don't ...
auksom Microcontroller MCU
TI blog post: How to select a power supply for automotive camera modules
[i=s]This post was last edited by qwqwqw2088 on 2020-9-27 10:12[/i]As automotive camera technology evolves to higher resolutions, dynamic ranges, and frame rates, power architectures need to be tailor...
qwqwqw2088 Analogue and Mixed Signal
About the program download problem of homemade STM32F4 system, No target connected
In my project, I need to design a data acquisition system using STM32F4. The PCB has been processed and there is no problem with the power supply. However, when I download the program for testing, I u...
EdwardsThompson stm32/stm8
EEWORLD University Hall----Live Replay: Evolution and Update of Keysight Signal Integrity Test
Live replay: Evolution and updates of Keysight signal integrity testing : https://training.eeworld.com.cn/course/6047...
hi5 Integrated technical exchanges
micropython update: 2020.8
August updates suddenly became lesspy/persistentcode: Maintain root ptr list of imported native .mpy code. extmod/vfs_reader: Fix mp_reader_new_file to open file in "rb" mode. tools/makemanifest.py: P...
dcexpert MicroPython Open Source section
Sanshe Rectifier Module
Series Power Module Data...
sh-caideqing Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1658  2445  1710  1025  741  34  50  35  21  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号