EEWORLDEEWORLDEEWORLD

Part Number

Search

NFS110-7924

Description
AC-DC Regulated Power Supply Module, 1 Output, Hybrid
CategoryPower/power management    The power supply circuit   
File Size98KB,3 Pages
ManufacturerArtysen Embedded Technologies
Download Datasheet Parametric Compare View All

NFS110-7924 Online Shopping

Suppliers Part Number Price MOQ In stock  
NFS110-7924 - - View Buy Now

NFS110-7924 Overview

AC-DC Regulated Power Supply Module, 1 Output, Hybrid

NFS110-7924 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
package instruction,
Reach Compliance Codeunknown
ECCN codeEAR99
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage253 V
Minimum input voltage90 V
JESD-30 codeR-XXMA-X16
JESD-609 codee0
Number of functions1
Output times1
Number of terminals16
Maximum operating temperature50 °C
Minimum operating temperature
Maximum output voltage30 V
Minimum output voltage24 V
Nominal output voltage24 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelCOMMERCIAL
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Fine-tuning/adjustable outputNO
Base Number Matches1
NFS110 Medical Series
Single and quad output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
7.0 x 4.25 x 1.8 inch package
Medical, dental and laboratory applications
Overvoltage and short circuit protection
110W with 20CFM
UL, VDE and CSA safety approvals
EN60601-1 and UL2601 medical approvals
80-110W AC/DC Universal Input Switch Mode Power Supplies
1
The NFS110 medical series is a 80 to 110W universal input AC/DC power supply on a 7
x 4.25 inch card with a maximum component height of 1.8 inches for use in medical
applications. The NFS110 medical series has the same generic feature set as the
standard NFS110 series but have been designed with lower safety ground leakage and
higher isolation as required for medical safety approval. The NFS110 provides 80W of
output power with free air convection cooling which can be boosted to 110W with
20CFM of air. Standard features include overvoltage and short-circuit protection. The
series, with full medical safety approval to EN60601 and UL2601, meets conducted
emissions EN55022 level A. The NFS110 medical series is designed for use in low
power medical, dental and laboratory applications such as dialysis machines,
monitoring equipment, instrumentation and infusion pump controls.
2 YEAR WARRANTY
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage adjustability
+5.1V output on multi’s
5.1V single
12V single
15V single
24V single
LL to HL, FL
All outputs on all units
At turn-on no load
All outputs
Multi output 5.1V only
5.1V single
12V single
15V single
24V single
Primary power
limited
±3.0%
±3.0%
12V to 14V
15V to 18V
24V to 30V
±0.1% max.
0%
±0.02%/°C
6.25V±0.75V
6.25V±0.75V
15.75V±1.0V
22V±1.5V
33V±2.5V
Pin max. 160W
Pout min. 110W
Burst mode operation
GENERAL SPECIFICATIONS
Hold-up time
110VAC
110VAC
230VAC
230VAC
@
@
@
@
80W
110W
80W
110W
35ms
17ms
140ms
100ms
70%
70%
72%
75%
typ.
typ.
typ.
typ.
Efficiency
Line regulation
Overshoot/undershoot
Temperature coefficient
Overvoltage protection
Multiple outputs
+5.1V single
12V and 15V singles
24V single
Input/output
Input/chassis
At 100 Watts output
At zero load
Isolation voltage
Switching frequency
Approvals and
standards
(See Note 12)
Weight
MTBF
4000VAC
1500VAC
20 to 70kHz
100 to 250kHz
Output power limit
Short circuit protection
INPUT SPECIFICATIONS
VDE0750, IEC60601
IEC1010, UL2601
CSA C22.2 No. 125
Singles
Multiple outputs
MIL-HDBK-217E
550g (19.4oz)
600g (21.2oz)
125,000 hours
ENVIRONMENTAL SPECIFICATIONS
Input voltage range
Input frequency range
Input surge current
Safety ground
leakage current
110VAC, 50Hz
230VAC, 50Hz
132VAC
264VAC
90 to 253VAC
127 to 357VDC
47Hz to 440Hz
17A
35A
50µA
100µA
Thermal performance
Operating, see curve
0°C to +70°C
Non-operating
–40°C to +85°C
0°C to +50°C,
80W
amb. convection cooled
+50°C to +70°C,
Derate 2W/°C
amb. convection cooled
0°C to +50°C,
110W
20CFM forced air
+50°C to +70°C,
Derate
20CFM forced air
2.75W/°C
Peak, 0°C to +50°C,
110W
max. 60 seconds
Non-condensing
Operating
Non-operating
5Hz to 500Hz
5% to 95% RH
10,000 feet max.
40,000 feet max.
2.4G approx.
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Level A
Level A
criteria 1
criteria 1
criteria 1
criteria 1
criteria 2
criteria 2
Relative humidity
Altitude
Vibration (See Note 11)
Perf.
Perf.
Perf.
Perf.
Perf.
Perf.
File Name: nfs110m.pdf Rev: 29 Aug 2005

NFS110-7924 Related Products

NFS110-7924 NFS110-7915 NFS110-7901P NFS110-7912
Description AC-DC Regulated Power Supply Module, 1 Output, Hybrid AC-DC Regulated Power Supply Module, 1 Output, Hybrid AC-DC Regulated Power Supply Module, 4 Output, 103.3W, Hybrid AC-DC Regulated Power Supply Module, 1 Output, Hybrid
Is it Rohs certified? incompatible incompatible incompatible incompatible
Reach Compliance Code unknown unknown unknown unknow
ECCN code EAR99 EAR99 EAR99 EAR99
Analog Integrated Circuits - Other Types AC-DC REGULATED POWER SUPPLY MODULE AC-DC REGULATED POWER SUPPLY MODULE AC-DC REGULATED POWER SUPPLY MODULE AC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage 253 V 253 V 253 V 253 V
Minimum input voltage 90 V 90 V 90 V 90 V
JESD-30 code R-XXMA-X16 R-XXMA-X16 R-XXMA-X16 R-XXMA-X16
JESD-609 code e0 e0 e0 e0
Number of functions 1 1 1 1
Output times 1 1 4 1
Number of terminals 16 16 16 16
Maximum operating temperature 50 °C 50 °C 50 °C 50 °C
Maximum output voltage 30 V 18 V 5.253 V 14 V
Minimum output voltage 24 V 15 V 4.947 V 12 V
Nominal output voltage 24 V 15 V 5.1 V 12 V
Package body material UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED
Package shape RECTANGULAR RECTANGULAR RECTANGULAR RECTANGULAR
Package form MICROELECTRONIC ASSEMBLY MICROELECTRONIC ASSEMBLY MICROELECTRONIC ASSEMBLY MICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius) NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
Certification status Not Qualified Not Qualified Not Qualified Not Qualified
surface mount NO NO NO NO
technology HYBRID HYBRID HYBRID HYBRID
Temperature level COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL
Terminal surface TIN LEAD TIN LEAD TIN LEAD TIN LEAD
Terminal form UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED
Terminal location UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED
Maximum time at peak reflow temperature NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
Fine-tuning/adjustable output NO NO NO NO
When compiling a multimedia program, an error message appears: cannot open input file 'strmiids.lib'
First, I customized a kernel with PB and generated the corresponding SDK. After installing the SDK, when debugging a multimedia program with EVC, I always get an error: [color=#FF0000]LINK : fatal err...
ggggds Embedded System
Carefully collected some licenses, hope to be useful
If you need it, just download it directly. There are 7.1, 7.2, 8.0 and 8.1...
zhangkai0215 FPGA/CPLD
What is SDR? Software Radio Basics
From military and aerospace to hobbyists, the promise of software-defined radio (SDR) is that with a single piece of hardware, users can capture, demodulate, and access RF signals across a wide range ...
Jacktang RF/Wirelessly
【MSP430 compiler usage experience】+IAR
[table=98%] [tr][td][float=right] [url=http://ad-apac.doubleclick.net/jump/N3736.EEWORLD/B2649702.6;sz=100x250][img]http://ad-apac.doubleclick.net/ad/N3736.EEWORLD/B2649702.6;sz=100x250[/img][/url][/f...
kaisy Microcontroller MCU
LPS33HW Waterproof Package Pressure Sensor
The STMicroelectronics LPS33HW pressure sensor is an ultra-compact piezoresistive sensor that functions as an absolute digital output barometer in a waterproof package. The LPS33HW pressure sensor con...
littleshrimp MEMS sensors
After the stm32 IO port is remapped, how to operate the original IO port?
stm32f107 After enabling pin remapping for several pins of the Ethernet interface, for example, PB5, the multiplexing function is a pin of ETH. Now that remapping is enabled, how can I continue to use...
yl20084784 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 404  2865  2497  1367  35  9  58  51  28  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号