C O A X I A L
C A B L E S
6.39
Standard Analog Video Cable
RG-11/U Type
Description
Part
No.
Standard
Nominal
Conductor
UL NEC/ Standard Lengths Unit Weight
Core OD
(stranding)
C(UL) CEC
Diameter
Type
Ft.
m
Lbs.
kg Nom. DCR Inch mm
Shielding Nominal OD
Materials
Nom. DCR Inch mm
Nominal
Nom. Nom. Capacitance
Vel.
Imp.
of
(Ω) Prop. pF/Ft. pF/m
Nominal
Attenuation
dB/
dB/
MHz 100 Ft. 100m
18 AWG
Stranded (7x26) .048″ Tinned Copper • 97% Bare Copper Braid Shield
Flame-retardant Semi-foam Polyethylene Insulation • Black PVC Jacket
80°C
8238
NEC:
CM
CEC:
CM
500
1000
152.4
304.8
59.0 26.8
117.0 53.2
18 AWG .285
(7x26)
.048″
TC
6.1Ω/M′
20.0Ω/km
7.24
BC Braid .405
97% Shield
Coverage
1.2Ω/M′
3.9Ω/km
10.29
75
66%
20.5
67.2
1
10
50
100
200
400
700
900
1000
1
10
50
100
200
400
700
900
1000
.2
.7
1.3
2.0
2.9
4.2
5.8
6.8
7.1
.2
.7
1.3
2.0
2.9
4.2
5.8
6.8
7.1
.6
2.2
4.3
6.6
9.5
13.8
19.0
22.3
23.3
.6
2.2
4.3
6.6
9.5
13.8
19.0
22.3
23.3
Polyethylene Insulation • Non-contaminating Black PVC Jacket
60°C
VW-1
8261
500
1000
152.4
304.8
52.5 23.9
104.0 47.3
18 AWG .285
(7x26)
.048″
TC
6.1Ω/M′
20.0Ω/km
7.24
BC Braid .405 10.29
97% Shield
Coverage
1.2Ω/M′
3.9Ω/km
75
66%
20.5
67.2
14 AWG
Solid .064″ Bare Copper • Duofoil
®
+ Tinned Copper Braid Shield
Gas-injected Foam HDPE Insulation • Black PVC Jacket
80°C
9292
1000
304.8
81.0 36.8
14 AWG
(solid)
.064″
BC
2.6Ω/M′
8.5Ω/km
.280
7.11
Duofoil
+ 60% TC
Braid
3.0Ω/M′
9.8Ω/km
.405 10.29
75
84%
16.1
52.8
1
10
50
100
200
400
700
900
1000
1
10
50
100
200
400
700
900
1000
.2
.5
.9
1.3
1.6
2.3
3.3
4.0
4.3
.2
.4
1.0
1.5
2.2
3.3
4.5
5.2
5.5
.6
1.6
3.0
4.3
5.3
7.6
10.8
13.1
14.1
.5
1.3
3.3
4.9
7.2
10.8
14.8
17.1
18.0
For Plenum versions of 9292,
see 89292.
100% Sweep tested. 5 MHz to 450 MHz.
Plenum • Foam FEP Insulation • Black FEP Jacket
200°C
89292
NEC:
CMP
CATVP
CEC:
CMP FT6
500
†
1000
†
152.4
304.8
39.5 18.0
77.0 35.0
14 AWG
(solid)
.064″
BC
2.5Ω/M′
8.2Ω/km
.274
6.96
Duofoil
+ 63% TC
Braid
3.0Ω/M′
9.8Ω/km
.346
8.79
75
83%
16.2
53.1
100% Sweep tested. 5 MHz to 450 MHz.
14 AWG
Solid .064″ Bare Copper • 97% Bare Copper Braid Shield
Gas-injected Foam HDPE Insulation • Black Polyethylene Jacket
80°C
8213
500
1000
2000
152.4
304.8
609.6
44.0 20.0
87.0 39.5
172.0 78.2
14 AWG
(solid)
.064″
BC
2.6Ω/M′
8.5Ω/km
.285
7.24
BC Braid .405 10.29 75
84% 16.1 52.8
97% Shield
Coverage
1.1Ω/M′
100% Sweep tested. 5 MHz to 450 MHz.
3.6Ω/km
1
10
50
100
200
400
700
900
1000
.2
.4
.9
1.3
1.9
2.9
4.1
4.8
5.2
.6
1.1
3.0
4.3
6.2
9.5
13.5
15.7
17.1
BC = Bare Copper • DCR = DC Resistance • HDPE = High-density Polyethylene • TC = Tinned Copper
Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference.
1-800-BELDEN-1.
Request quotations of RG/U cables not listed.
†
Spools and/or UnReel
®
cartons are one piece, but length may vary ±10% from length shown.
B e l d e n E l e c t r o n i c s D i v i s i o n
Te c h n i c a l S u p p o r t :
1 - 8 0 0 - B E L D E N - 1
o r
1 - 8 0 0 - B E L D E N - 3
•
w w w . b e l d e n . c o m
6
•
Coaxial Cables