EEWORLDEEWORLDEEWORLD

Part Number

Search

930C4P18K-F

Description
TELECOM AND DATACOM CONNECTOR
Categorysemiconductor    Other integrated circuit (IC)   
File Size259KB,3 Pages
ManufacturerCDE [ CORNELL DUBILIER ELECTRONICS ]
Download Datasheet View All

930C4P18K-F Online Shopping

Suppliers Part Number Price MOQ In stock  
930C4P18K-F - - View Buy Now

930C4P18K-F Overview

TELECOM AND DATACOM CONNECTOR

Axial Leaded Metallized Polypropylene
Type 930
Polypropylene Film Capacitors
Type 930 axial-leaded, metallized polypropylene
capacitors are available in a wide range of capacitance
values in small case sizes with a flame-retardant
tape wrap and epoxy end seals that provide moisture
resistance. Type 930 is used most frequently in high-
voltage/high-frequency switching power supplies where
superior stability and AC performance characteristics
are important. This film capacitor has Underwriters
Laboratories, Inc. recognition for construction only under
U.L. File Number E128034(N).
CD
E
Highlights
Outline Drawing
#20 AWG (.032 dia)
Tinned Solid Copper Leads
Small case sizes
Ripple Current Capacity
Suitable for high frequency operation
1.625
Min
(41.28 mm)
Specifications
L
+0.062
(1.5)
1.625
Min
(41.28 mm)
NOTE:
Other capacitance values, sizes and performance
specifications are available. Contact us.
.022 to 10.0 µF
100 to 630 Vdc (70 to 275 Vac 60 Hz)
±10% (K) Standard; ±5% (J) Optional
–55 ºC to +105 ºC*
*Full rated voltage at 85 ºC - derated linearly to 50%
Complies with the EU Directive
rated at 105 ºC
2002/95/EC requirement
Dielectric Withstand voltage:
200% for 1 minute
restricting the use of Lead (Pb),
Dissipation Factor (DF):
0.10% Max. (25 ºC, 1 kHz)
Mercury (Hg), Cadmium (Cd),
Hexavalent chromium (Cr(VI)),
Insulation Resistance:
200,000 MΩ x µF
PolyBrominated Biphenyls (PBB)
400,000 MΩ Min.
and PolyBrominated Diphenyl
Ethers (PBDE).
Life Test:
1,000 hours at 85 ºC at 125% rated voltage
Capacitance Range:
Voltage Range:
Capacitance Tolerance:
Operating Temperature Range:
Ratings
Cap.
(µF)
.22
.27
.33
.39
.47
.56
.68
.82
1.00
D
Catalog
Part Number
930C1P22K–F
930C1P27K–F
930C1P33K–F
930C1P39K–F
930C1P47K–F
930C1P56K–F
930C1P68K–F
930C1P82K–F
930C1W1K–F
Max.
L
+0.062 (1.5)
ESR
20-100 kHz dV/dt
100 Vdc (70 Vac)
Maximum Ripple Current (Amps rms) at 20 kHz
Case Temperature
Inches (mm) Inches (mm) (milliohms) (V/µs) +25 ºC +35 ºC +45 ºC +55 ºC +65 ºC +75 ºC +85 ºC
.275
.298
.324
.347
.376
.321
.348
.377
.421
(7.0)
(7.6)
(8.2)
(8.8)
(9.5)
(8.2)
(8.8)
(9.6)
(10.7)
.750
.750
.750
.750
.750
(19.0)
(19.0)
(19.0)
(19.0)
(19.0)
---
---
---
---
37
35
33
31
26
25
25
25
25
25
14
14
14
14
3.7
3.9
4.1
4.3
5.5
3.4
3.6
3.8
4.0
5.1
3.1
3.3
3.5
3.6
4.7
2.8
2.9
3.1
3.2
4.2
2.5
2.6
2.8
2.9
3.6
2.0
2.1
2.2
2.3
2.8
1.4
1.5
1.6
1.7
2.6
1.000 (25.4)
1.000 (25.4)
1.000 (25.4)
1.000 (25.4)
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830 • www.cde.com
Problems with stm8 debugging
#error clnk Debug\ed.lkf:1 segment .text size overflow (87)The command: "clnk -l"C:\Program Files\COSMIC\CXSTM8\Lib" -o Debug\ed.sm8 -mDebug\ed.map Debug\ed.lkf " has failed, the returned value is: 1e...
llovehsy stm32/stm8
Technology Live: MEMS sensors usher in a new era of condition monitoring, ADI takes you into the kingdom of cold machines
If you don't understand the language, there is a translation egg. If you don't understand the cold machine, how can you get into it? The answer is to participate in ADI's [MEMS sensors open a new era ...
EEWORLD社区 Sensor
Will the data stored in MSP430 FLASH be lost after power failure and restart?
Doesn't the MSP430 need to write and erase the flash when programming? Then, will the data stored in the flash be erased? How can I prevent the data saved during programming from being erased? Please ...
sdnumcu Microcontroller MCU
Configuration example: Connecting flow meter to PLC via Modbus to Porfinet gateway
[i=s]This post was last edited by Xiaojiang Intelligent Control on 2022-2-24 20:45[/i]Configuration example: Connecting flow meter to PLC via Modbus to Porfinet gatewayCase introduction:This case is a...
小疆智控 Industrial Control Electronics
How to change the picture in the picturesbox control when developing windows mobile in vs2005 c#.
Like clicking a button or something like that....
snowingsuning Embedded System
The mini2440 timer has a timing error of 100ns~300ns!! Can you help me analyze the reason? Thank you!
I am using a bare-metal program, not an embedded system. I am using timer 0, with a timer interrupt time of 10 microseconds. In the timer interrupt, the GPB7 port outputs high and low levels. I use an...
whaidong123 Real-time operating system RTOS

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1120  45  1398  2059  1634  23  1  29  42  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号