EEWORLDEEWORLDEEWORLD

Part Number

Search

326XAX48P0.2F24VDC

Description
On-Delay Relay, SPDT, Momentary, 0.083A (Coil), 24VDC (Coil), 2000mW (Coil), 10A (Contact), 28VDC (Contact), 0.2s, DC Input, AC/DC Output, Socket Mount
CategoryMechanical and electronic products    relay   
File Size458KB,2 Pages
ManufacturerStruthers-Dunn
Download Datasheet Parametric View All

326XAX48P0.2F24VDC Overview

On-Delay Relay, SPDT, Momentary, 0.083A (Coil), 24VDC (Coil), 2000mW (Coil), 10A (Contact), 28VDC (Contact), 0.2s, DC Input, AC/DC Output, Socket Mount

326XAX48P0.2F24VDC Parametric

Parameter NameAttribute value
MakerStruthers-Dunn
Reach Compliance Codeunknown
ECCN codeEAR99
body width34.9 mm
body height74.9 mm
Body length or diameter34.9 mm
Maximum coil current (DC)0.083 A
Coil operating voltage (DC)19.2 V
Coil power2000 mW
Coil resistance289.16 Ω
Maximum coil voltage (DC)24 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load10A@240VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@28VDC
Maximum contact voltage (AC)240 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
timed delay0.2 s
Manufacturer's serial number326
Installation featuresSOCKET MOUNT
Maximum operating temperature70 °C
Minimum operating temperature-20 °C
physical size34.9mm X 34.9mm X 74.9mm
GuidelineUL
Relay actionMOMENTARY
Relay functionSPDT
Relay typeON-DELAY RELAY
surface mountNO
Termination typeSNAP-ON
Base Number Matches1
326/327 Series - Time Delay Relay
SPDT - 3PDT, 10 Amp
E13224
The 326 on delay and 327 off delay are “octal” base constructed time delay relays. Both AC and
DC versions are available. On delays can have up to three poles. The timing circuit is a fully
encapsulated precision RC (resistor – capacitor) network typically used in applications where
oscillators are not desired. Fixed time versions are available. Single pole and double pole
versions have 8 pin bases. The 3 pole version has 11 pins. All are intended for socket mounting.
GENERAL SPECIFICATIONS (@ 25° C)
Timing:
Functions Available
Time Range
Timing Adjustment
Timing Repeatability
(Constant voltage and temperature)
Reset Time maximum
Input Pulse Length minimum
Contacts:
Contact Configuration
Contact Material
Contact Rating
120 / 240VAC Resistive
28VDC Resistive
Motor 120VAC
Motor 240VAC
Minimum Contct Load
Contact Resistance, Initial
Coil:
Coils Available
Nominal Coil Power
Input Voltage Tolorance -AC
Input Voltage Tolorance -DC
Transient Protection
Reverse Polarity Protection
Duty
Dielectric Strength:
Across Open Contacts
Between Mutally Insulated Points
Insulation Resistance
Temperature:
Operating
Storage
Life Expectancy:
Electrical (full load operations)
Mechanical (no load operations)
Miscellaneous:
Mounting Position
Mating Socket
Enclosure
Weight
On-delay, Off-delay
Up to 300 seconds
Knob
3%
150mS
50mS
SPDT, DPDT, 3PDT
Silver Alloy
10 Amp / 10 Amp
10 Amp
1/3Hp
1/2Hp
500mW
100 milliohms max @ 6VDC, 1A
AC and DC
2.75VA 2W
85% to 110% of nominal
80% to 110% of nominal
Yes
Yes
Continuous
500Vrms
1500Vrms
1,000 Mohms min @ 500VDC
-20 to 70°C (-4 to 158°F)
-40 to 85°C (-40 to 185°F)
100,000
10,000,000
Any
8 pin = SK-CIR8-DS
11 pin = SK-CIR11-DS
Clear Polycarbonate
5.0oz (142 grams)
Ordering Code 326 XAX 48P
Series
326 - On delay
327 - Off delay
Contact Arrangement
XAX (SPDT) - (1 form C)
XBX (DPDT) - (2 form C)
XCX (3PDT) - (3 form C)
Construction Style
Octal style plug-in - CODE 48P
Non standard wiring - CODE 48P - K
Timing Ranges
0.1 - 1.0 Seconds - CODE 001
0.2 - 2.0 Seconds - CODE 002
1.0 - 10 Seconds - CODE 010
3.0 - 30 Seconds - CODE 033
6.0 - 60 Seconds - CODE 060
18 - 180 Seconds - CODE 180
30 - 300 Seconds - CODE 300
Adjustment Options
Adjustment knob - No CODE
Fixed - Specify fixed time - CODE F 3F - 3 seconds
fixed (ie. 3F)
Remote adjustment - CODE R (SPDT, DPDT only) (Call)
Operating Voltage
AC: 24, 120, 240, (Add VAC)
DC: 12, 24, 115-125 (Add VDC)
001 F
120VAC
7/15
www.struthers-dunn.com
(843) 664-3303
【R7F0C809】Part 2 Software Upgrade
[align=center][color=red][font=宋体][size=22.0pt]Chapter 2[/size][/font][/color][color=red][font=宋体][size=22.0pt] [/size][/color][color=red][font=宋体][size=22.0pt] [/size][/color][color=red][font=宋体][siz...
常见泽1 Renesas Electronics MCUs
【R7F0C809】+ Overall solution for blood oxygen saturation and heart rate measurement
[i=s] This post was last edited by RMB Fantasy on 2015-11-18 20:48 [/i] [align=left]After determining the project, the next step is to select the project plan. [/align][align=left]For this non-invasiv...
人民币的幻想 Renesas Electronics MCUs
Using STM32's MPU (Memory Protection Unit) to implement code isolation and access control
Problem/Goal and SolutionObjective: Only allow "high-level functions" to access data in OTP, other applications cannot directly read OTP contentExample @ F413-Nucleo, F401-NucleoTarget environmentThe ...
nmg stm32/stm8
C implementation of incremental pid algorithm in msp430 microcontroller
#include  #include  struct _pid {    int pv; /*integer that contains the process value*/    int sp; /*integer that contains the set point*/    float integral;    float pgain;    float igain;    float ...
灞波儿奔 Microcontroller MCU
How to emulate ROM generated by ISE
The simulation of Xilinx's ROM in modelsim fails, and it says that the .mif file cannot be read!!!...
vbeau FPGA/CPLD
【Video】HPS access FPGA experiment
[media=swf,500,375]http://player.youku.com/player.php/sid/XNzI3NjE0MjEy/v.swf[/media]...
chenzhufly FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 885  1115  1029  2438  1176  18  23  21  50  24 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号