EEWORLDEEWORLDEEWORLD

Part Number

Search

A214903

Description
Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size2MB,6 Pages
ManufacturerEaton
Download Datasheet Parametric View All

A214903 Overview

Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)

A214903 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSAFETY APPROVAL: UL 94V-0, THERMOPLASTIC
Fastening methodSCREW
Manufacturer's serial numberA2
Installation typeBOARD
Number of layers1
Rows1
Number of channels3
Rated current30 A
Rated voltage300 V
safety certificateUL; CSA; CE; IEC
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge12 AWG
Base Number Matches1
MAGNUM
®
Series A2000, LP2000 & CB2000
Single Row Terminal Blocks
Single & Double Row
Filtered Connectors
A20510807WR
Euro-MAG Series
PCB – Spring Clamp
SPECIFICATIONS
Rating:
A2: 30A, 300V*
LP2: 30A, 150V*
CB2: 30A, 300V*
Center Spacing:
.375” or 3/8” (9.52 mm)
LP202110
Wire Range:
#12-22 AWG CU
Screw Size:
#6-32 zinc plated philslot
Torque Rating:
9 in-lb.
Base:
Standoffs standard for easy flux washing
Distance Between Barriers:
.32” (8.1 mm)
Recommended PCB Hole Diameter:
.076” (1.93 mm)
Operating Temperature
: 105°C (221°F) max., -40°C (-40°F) min.
Molded Material:
Black, UL Rated 94V0 Thermoplastic
Breakdown Voltage:
3400V (A2 & LP2); 4100V (CB2).
Agency Information:
UL/CSA; IEC Compliance;
CE Certified
*30A Rating achieved with a #10 copper wire crimped to a ring terminal.;
20A Rating without ring terminal.
CB20210507
A2000 & LP2000 Series
.375
(9.53)
.15
(3.8)
dia.
.65
(16.5)
Poles
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
MOUNTING
ENDS
ONLY
A
C
Mount Ctrs.
Length
1.13
1.50
1.88
2.25
2.63
3.00
3.38
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
1.56
1.93
2.30
2.68
3.06
3.43
3.81
4.18
4.56
4.93
5.31
5.69
6.06
6.43
6.81
7.18
7.56
7.93
8.31
8.68
9.06
9.43
9.81
10.18
10.56
10.93
11.31
11.68
12.05
BARRIER &
MOUNTING
ENDS
B
Pole Ctrs.
.38
.75
1.13
1.50
1.88
2.25
2.63
3.00
3.38
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
BARRIER
ENDS
ONLY
C
Length
.81
1.18
1.56
1.93
2.31
2.68
3.06
3.43
3.81
4.18
4.56
4.93
5.31
5.68
6.06
6.43
6.81
7.18
7.56
7.93
8.31
8.68
9.06
9.43
9.81
10.18
10.55
10.93
11.31
11.68
12.05
C
Mount End
Barrier End
Base & Rail Mount
Connectors
.76 (19.3)
.40
(10.2)
.565 (14.35)
on LP2000
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
CB2000 Series
.19
(4.8)
dia.
Power Distribution Blocks
.375
(9.53)
.70
(17.8)
.32
(8.1)
Mount End
C
Barrier End
.60
(15.2)
WIRE MANAGEMENT PRODUCTS
* Dimensions in inches. To convert to millimeters, multiply by 25.4.
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
6
Nucleo in-depth evaluation] CUBE rapid development of RTC + serial port printing
1. Use the NUCLEO board L053. External 32.768K crystal and serial port 2 (because this is connected to the serial port 2 of STLINK, convenient). 2. Use CUBE to configure the RTC external clock, config...
damiaa MCU
Delay problem of STPC ATLAS PC/104 board, using VS2003 to develop WINCE4.2 program
I use VS2003 to develop WINCE4.2 programs. The board is STPC ATLAS PC/104 of msc. The onboard configuration is CPU: STPC Atlas 133MHz, 100MHz Front Side Bus, 8 KByte unified instruction and data cache...
w2008r Embedded System
During circuit inspection, which components can be inspected in the circuit and which need to be removed for inspection?
Let's discuss this question with you. Which components can be directly tested in the circuit during the circuit inspection? I first thought of a parameter, which is the voltage to ground. The voltage ...
五加一等于六 51mcu
Does anyone have experience in programming to control Scratchpad Memory?
I want to make a program to dynamically control SPM for the purpose of saving energy, but there are several problems that have not been solved. The basic idea is to run an optimization program for a (...
6565 Embedded System
STM32MP157A-DK1 Evaluation (7) M4 Core Program Test
[i=s]This post was last edited by cruelfox on 2020-4-30 00:46[/i]  I have been playing with the Cortex-A7 core of the STM32MP157A because it is new to me. In addition to the two A7 cores, this chip is...
cruelfox Special Edition for Assessment Centres
Unable to download the program, prompting 0h verification failed..
First, the cable supports AVR. Bought it online.Connected like this, can't download, help. Schematic diagram:...
CMLite Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1803  1230  1202  1025  825  37  25  21  17  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号