All specifications are typical at nominal input, full load at 25 °C unless otherwise stated.
EMC Charateristics
Conducted emissions:
Radiated emissions:
ESD air:
ESD contact:
Surge:
Fast transients:
Radiated immunity:
Conducted immunity:
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-2, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
120 Vac, 60 Hz
120 Vac, 65 W
Input/output
Input/chassis
Fixed
283 g (10 oz)
MIL-HDBK-217F
150,000 hours
Level A
Level A
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 2
Perf. criteria 2
16 ms @ 65 W
72% typical
4000 Vac
1500 Vac
100 kHz, ± 5 kHz
Rev.11.2.09_104
NLP65 Medical
2 of 4
General Specifications
Hold-up time:
Efficiency:
Isolation voltage:
Switching frequency:
Approvals and standards:
Weight:
MTBF demonstrated:
EN60601, UL2601, CSA 22.2 No. 125
Environmental Specifications
Thermal performance:
Operating ambient
(See derating curve)
Non-operating
0 °C to 50 °C, ambient,
convection cooled
50 °C - 70 °C ambient,
convection cooled
Peak (0 °C to 50 °C, 60 s)
Relative humidity:
Altitude:
Vibration (See Note 5):
Shock
Non-condensing
Operating
Non-operating
5 - 500 Hz
per MIL-STD-810E
0° C to +70 °C
-40 °C to +85 °C
65 W
Derate to 50% load
See table
5 to 95% RH
10,000 feet max.
30,000 feet max.
2.4 G rms approx.
516.4 Part IV
0°C
10°C 20°C 30°C 40°C 50°C 60°C 70°C
NATURAL
CONVECTION
COOLING
38W
32W
75W
20 CFM FORCED AIR COOLING
65W
DERATING CURVE
Output Power (Watts)
Embedded Power for
Business-Critical Continuity
Ordering Information
Output
Voltage
+5 V
+12 V
–12 V
+5 V
+24 V
+5 V
+12 V
+12 V
+15 V
+24 V
Output Current
Max
(1)
7A
2.5 A
0.5 A
7A
2A
7A
2.5 A
5.4 A
4.4 A
2.7 A
Peak
9.1 A
3.3 A
0.81 A
9.1 A
2.6 A
9.1 A
3.3 A
7A
5.7 A
3.5 A
Fan
(10)
8A
3A
1A
8A
2A
8A
3A
6.5 A
5.3 A
3.5 A
Ripple
(4)
50 mV
150 mV
120 mV
50 mV
240 mV
50 mV
150 mV
120 mV
150 mV
240 mV
Total
Regulation
(6)
±2.0%
±5.0%
±5.0%
±2.0%
±5.0%
±2.0%
±5.0%
±2.0%
±2.0%
±2.0%
NLP65-9912J
NLP65-9915J
NLP65-9924J
NLP65-9929J
NLP65-9920J
Model Number
(11, 12)
NLP65-9908J
Rev.11.2.09_104
NLP65 Medical
3 of 4
Notes
Natural convection cooling. Models NLP65-9929J, and NLP65-9908Jmust not exceed 62.5 Watts continuous output power with natural convection. Model
NLP65-9920J not to exceed 65 Watts continuous output power with natural convection.
2
When the input voltage is less than 90 Vac the operating temperature range is 0
°
C to +40
°
C. The ripple and regulation specifications may not be met.
3
Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total regulation limits.
4
Figure is peak-to-peak for convection power rating. Output noise measurements are made across a 20 MHz bandwidth using a 6 inch twisted pair, terminated
with a 10 µF electrolytic capacitor and a 0.1 µF ceramic capacitor.
5
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz.
6
To maintain stated regulation then:
for single output units
I ≥ 0.2 A I max.
for multiple output units
0.25 ≤ I(A)/I(B) ≤ 5, for I(A) ≥ 0.2 A I(A) max.
7
For optimum reliability, no part of the heatsink should exceed 120
o
C, and no semiconductor case temperature should exceed 130
o
C.
8
CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements.
9
This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product.
10
Maximum continuous output power for all multiple output models must not exceed 75 Watts with 20 CFM forced air cooling at 50
o
C.
11
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
12
NOTICE: Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search
tool at http://www.PowerConversion.com to find a suitable alternative.
1
Embedded Power for
Business-Critical Continuity
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Rev.11.2.09_104
NLP65 Medical
4 of 4
5.00
(127.00)
4.550
(115.57)
J1
3 N
1 L
3.00
(76.20)
J2
C19
6
T1
2.550
(64.770)
0.225
(5.715)
Europe (UK)
J3
1
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
Mounting
Hole Diameter
0.156 (4.00)
ALL DIMENSIONS IN INCHES (mm)
MAXIMUM COMPONENT
HEIGHT 1.26 (32.00)
TOLERANCE: .xxx
0.005"
.xx
0.02"
www.PowerConversion.com
techsupport.embeddedpower@
emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
Hello, everyone~~ Today's weekly evaluation report is here~~ Sorry for keeping you waiting~~ Let's take a look~Activities in the application period:
1. Free evaluation of EVK-NINA-B400 wireless develo...
Make a minimum system board: If you have never done ARM development, it is recommended that you do not be greedy and try to complete all the applications at the beginning, because the startup method o...
I recently came into contact with DC boost circuits. I can now use a charge pump to boost a 3.6V power supply to about 15V. I want to continue to boost it to 30V but I have encountered difficulties. I...
1. Introduction
RFID (radio frequency identification) is a non-contact automatic identification technology that emerged in the 1990s. It uses the characteristics of radio frequency signal prop...[Details]
introduction
With the continuous optimization of surface mount technology (SMT) and the rapid development of chip component manufacturing technology, the application of chip mounters in the el...[Details]
1. Introduction
Automobile pollution is one of the most important issues that people are most concerned about and need to solve urgently. As an important method for detecting automobile exhau...[Details]
Analog engineers have traditionally struggled with complexity when designing power supplies that required multiple outputs, dynamic load sharing, hot-swap, or extensive fault-handling capabilities....[Details]
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
The reason for the light decay of white LEDs: the decline of phosphor performance
So far, the rapid decline of the luminous performance of white light LEDs, especially low-power white light LE...[Details]
Introduction
Power subsystems are becoming more and more integrated into the overall system. Power systems have moved from being separate "essential dangerous devices" to being monitorable...[Details]
Electronic systems are located at different points on the automotive power bus and therefore often need to operate under very stringent power requirements. These include load dump, cold crank, very lo...[Details]
Power management solutions for today's portable application processors are becoming increasingly integrated. Total power consumption, standby and sleep current consumption affect battery size, bill...[Details]
1. Introduction
At present, most lighting equipment still uses traditional energy for lighting. Making full use of solar energy as the energy supply for lighting equipment is of great si...[Details]
Overview:
This paper introduces a method of connecting a CAN-bus network with Ethernet to form a medium-sized remote monitoring/data transmission network.
CAN (Controller Area Network) is ...[Details]
1. Introduction
Testing the temperature of steel billets before rolling is an important measure to ensure the quality of steel. Traditional manual testing is difficult to ensure product qu...[Details]
Many battery-powered systems require a visual indicator to show when the battery needs to be replaced. LEDs are commonly used for this purpose, but they consume at least 10mA of current. This con...[Details]
Continuity test
A variety of devices need to be checked for continuity, including cable assemblies, printed circuit boards, and connectors to ensure that these components have the expected contin...[Details]
1. Disadvantages of choosing too high a voltage level
Choosing too high a voltage level will result in too high an investment and a long payback period. As the voltage level increases, the...[Details]