DF11-ABC6M150C0.0015.029

Description
Mains Power Connector, 10/15A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size913KB,5 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

DF11-ABC6M150C0.0015.029 Overview

Mains Power Connector, 10/15A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT

DF11-ABC6M150C0.0015.029 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codenot_compliant
Other featuresSTANDARDS: IEC/EN 60320-1/C14, UL 94V-0; UL 498, CSA C22.2, VDE, QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact completed and terminatedTin (Sn) - with Nickel (Ni) barrier
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3
MIL complianceNO
Power Connector Ratings10/15A, 250VAC
Plug informationMULTIPLE MATING PARTS AVAILABLE
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
Power entry modules without line filter
www.schurter.com/pg05
IEC Appliance Inlet C14 with recessed Circuit Breaker TA45
DF
C14
70° C
Description
- Panel Mount:
Screw-on version from front or rear side, snap-in version from front
side
- 2 Functions:
Appliance Inlet Protection class I, circuit breaker type TA45 2-pole
- Quick connect terminals 6.3 x 0.8 mm
Characteristics
- All single elements are already wired
- Switch non-illuminated or illuminated
Thermal overload protection
Optional with undervoltage- or remote trip release
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
Approvals
- VDE Certificate Number: 40011305
- UL File Number: E96454
- Unwired versions
- Line switch 1-pole
- Other rocker marking
- Variant with notch for V-Lock mating Cordsets
Alternative: version with line filter DF12
Substitute for type 6145
pdf, General Product Information, Approvals, RoHS, CHINA-RoHS,
Mating Connectors, e-Store, SCHURTER-Stock-Check, Distributor-
Stock-Check, Accessories
References
Weblinks
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
10 A / 250 VAC; 50 Hz
1 - 15 A / 250 VAC; 60 Hz
> 2.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
-10 °C to 55 °C
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1/1.5/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance Inlet
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Rocker switch 2-pole, non-illuminated
or illuminated, acc. to IEC 61058-1
Technical details
Circuit Breakers
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Line Switch
Material: Housing
Connectors

430 MCU Flash Operation (with source code and debugging process)
This article is published only to start a discussion. I am honored that you can learn the operation of Flash thoroughly! 1. Brief introduction of Flash: Flash is a kind of storage chip, and the data i...
qcxycwf MCU
A brief introduction to MHL
[size=4][color=black][font=宋体]With the gradual popularization and promotion of digital TV and portable audio-visual devices, consumers' demand for delivering digital high-definition content to persona...
1055875333 Mobile and portable
Source code of "Microcontroller Typical Module Design Example Navigation"
[color=#666666]Directory: [/color]Chapter 1 Basic port operations of 51 MCU1.1 Light up the simplest MCU system1.2 Brighter small lights1.3 Small lights that turn on and off at a fixed time1.4 Manual ...
maxmax007 MCU
C language implementation of string library functions (debugged with VC++6.0)
#include stdio.h char * str_index( char *string, char letter){ while ((*string != letter)(*string)) string++; if(*string=='\0') return(0); else return(string);} void main(){ char * pt;pt=str_index("ch...
zhangle0922 ARM Technology
Serial to Ethernet Interface Data Pack
Serial to Ethernet interface package, including BOM list...
taburiss001 Microcontroller MCU
Let’s talk about what issues you should pay attention to when using 51.
I skipped the parts I didn't understand at the beginning. I don't know what the problems were before. Anyway, I know it now....
天使疯子 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1937  1372  1349  2465  871  40  28  50  18  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号