LP209431

Description
Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size2MB,6 Pages
ManufacturerEaton
Download Datasheet Parametric View All

LP209431 Overview

Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)

LP209431 Parametric

Parameter NameAttribute value
MakerEaton
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSAFETY APPROVAL: UL 94V-0, THERMOPLASTIC
Fastening methodSCREW
Manufacturer's serial numberLP2
Installation typeBOARD
Number of layers1
Rows1
Number of channels31
Rated current30 A
Rated voltage150 V
safety certificateUL; CSA; CE; IEC
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge12 AWG
MAGNUM
®
Series A2000, LP2000 & CB2000
Single Row Terminal Blocks
Single & Double Row
Filtered Connectors
A20510807WR
Euro-MAG Series
PCB – Spring Clamp
SPECIFICATIONS
Rating:
A2: 30A, 300V*
LP2: 30A, 150V*
CB2: 30A, 300V*
Center Spacing:
.375” or 3/8” (9.52 mm)
LP202110
Wire Range:
#12-22 AWG CU
Screw Size:
#6-32 zinc plated philslot
Torque Rating:
9 in-lb.
Base:
Standoffs standard for easy flux washing
Distance Between Barriers:
.32” (8.1 mm)
Recommended PCB Hole Diameter:
.076” (1.93 mm)
Operating Temperature
: 105°C (221°F) max., -40°C (-40°F) min.
Molded Material:
Black, UL Rated 94V0 Thermoplastic
Breakdown Voltage:
3400V (A2 & LP2); 4100V (CB2).
Agency Information:
UL/CSA; IEC Compliance;
CE Certified
*30A Rating achieved with a #10 copper wire crimped to a ring terminal.;
20A Rating without ring terminal.
CB20210507
A2000 & LP2000 Series
.375
(9.53)
.15
(3.8)
dia.
.65
(16.5)
Poles
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
MOUNTING
ENDS
ONLY
A
C
Mount Ctrs.
Length
1.13
1.50
1.88
2.25
2.63
3.00
3.38
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
1.56
1.93
2.30
2.68
3.06
3.43
3.81
4.18
4.56
4.93
5.31
5.69
6.06
6.43
6.81
7.18
7.56
7.93
8.31
8.68
9.06
9.43
9.81
10.18
10.56
10.93
11.31
11.68
12.05
BARRIER &
MOUNTING
ENDS
B
Pole Ctrs.
.38
.75
1.13
1.50
1.88
2.25
2.63
3.00
3.38
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
BARRIER
ENDS
ONLY
C
Length
.81
1.18
1.56
1.93
2.31
2.68
3.06
3.43
3.81
4.18
4.56
4.93
5.31
5.68
6.06
6.43
6.81
7.18
7.56
7.93
8.31
8.68
9.06
9.43
9.81
10.18
10.55
10.93
11.31
11.68
12.05
C
Mount End
Barrier End
Base & Rail Mount
Connectors
.76 (19.3)
.40
(10.2)
.565 (14.35)
on LP2000
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
CB2000 Series
.19
(4.8)
dia.
Power Distribution Blocks
.375
(9.53)
.70
(17.8)
.32
(8.1)
Mount End
C
Barrier End
.60
(15.2)
WIRE MANAGEMENT PRODUCTS
* Dimensions in inches. To convert to millimeters, multiply by 25.4.
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
6
Get free high-speed digital design tips to avoid starting over with complex PCB designs
High-speed digital design and measurement are becoming increasingly complex.Do you always find distorted voltage waveforms only in the late stages of design? All yourprevious efforts go to waste, and ...
nmg Power technology
Philips RF SiP sets new standard for GSM/GPRS/EDGE radio unit size
Philips RF SiP sets new standard for GSM/GPRS/EDGE radio unit size50% smaller RF transceiver application enables more functionality to be integrated into Nexperia cellular system solutions2004-04-26  ...
fighting Analog electronics
What is a feedback circuit? What does feedback do?
Feedback circuits are widely used in various electronic circuits. Feedback is to feed back part or all of the amplifier output signal (voltage or current) to the amplifier input terminal for compariso...
fish001 Analogue and Mixed Signal
MSP-EXP432P401R LaunchPad User Guide
MSP-EXP432P401R LaunchPad User Guide...
Jacktang Microcontroller MCU
Special praise: wateras1 asked questions about the exam questions in the activity!
[url=https://www.eeworld.com.cn/huodong/201507TI_WCS/]>>IoT Mid-Year Exam: How Much Do You Know About Wireless Connection Technology? [/url] The activity is in progress... Nearly 50 students have pass...
soso Talking
The spindle is swinging and oscillating on its own?
Our company has a turning center with a C-axis. Now when it is turned on, the spindle swings back and forth repeatedly (without any operation), without any alarm. What is the problem? The spindle is a...
eeleader-mcu Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2443  124  855  859  2832  50  3  18  58  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号