EEWORLDEEWORLDEEWORLD

Part Number

Search

HGN-375A01W-57-1MM1

Description
Mains Power Connector, 1A, 125/250VAC, Male, Socket
CategoryThe connector    The connector   
File Size485KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Environmental Compliance  
Download Datasheet Parametric View All

HGN-375A01W-57-1MM1 Overview

Mains Power Connector, 1A, 125/250VAC, Male, Socket

HGN-375A01W-57-1MM1 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerPower Dynamics, Inc.
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC 60320; UL; VDE
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings1A, 125/250VAC
Manufacturer's serial numberHGN-375
Installation typePANEL
OptionsGENERAL PURPOSE
Total number of contacts3
HGN-375(A, B, C)
FUSED WITH ON/OFF SWITCH, IEC 60320 POWER INLET
SOCKET WITH FUSE/S (5X20MM)
MECHANICAL DIMENSIONS
(Unit: mm)
CASE A
49.83
60.71
55.04
65.4
Use only with a 250V Fuse
Employer uniqement avec
un fusible de 250V
60.0
O
32.45
-
40 + 0.2
3.5
49.37
2x M3
61.5
CASE B
FEATURES
2x 3.3
The HGN-375(A, B, C) series offers filters in three different
package styles - Flange mount (sides), Flange mount (top/
bottom), & snap-in type. This cost effective series offers more
component options with better performance in curbing
common and differential mode noise. These filters are
equipped with IEC connector, fuse holder for one or two 5 x
20 mm fuses, 2 pole on/off switch and fully enclosed metal
housing.
These filters are also available for Medical equipment with
low leakage current and have been designed to bring various
medical equipments into compliance with EN55011 and FCC
Part 15J, Class B conducted emissions limits.
82
72
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
28.5
4x R0.5
6.30 TYP.
-
40.0+ 0.2
RECOMMENDED PANEL CUTOUT
(MOUNT FROM FRONT)
R2.5 TYP.
2x 3.5
29.3
+0.5
60.8
+0.5
72.0
+0.1
29 6.3 TYP.
29.5
59.8
48.7
(3.5)
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
CASE C
(61.3)
(56.2)
TECHNICAL DATA
Rated Voltage: 125/250VAC
Rated Current: 1A, 2A, 3A, 4A, 6A, 10A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.5mA, max
@ 250VAC 50Hz: 1.0mA, max
@ 125VAC 60Hz: 2
µ
A*, max
@ 250VAC 50Hz: 5
µ
A*, max
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
65 59.5
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
59.8
28
32
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
48.7
(3.5)
R2.5 TYP.
29.3
+0.5
29 6.3 TYP.
61.4
+0.3
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
81
LM3S UART data transmission problem
When LM3S sends a data packet to the computer via UART, the computer only receives the first few bytes. What could be the problem?...
amy_shen Microcontroller MCU
I need help from a great person regarding CC2520 configuration. I'm so anxious.
I want to make a simple communication between two CC2520 and I encountered some difficulties. Could you please help me? 1.uint8 pdata CC2520_PSDU[1+CC2520_PSDU_Len]; uint8 CC2520_Source_PANID[2] = {0x...
liujilei Wireless Connectivity
Help!!! The task runs away when creating in UC/OSII
I created a start task, which ran successfully. But it ran away when I created the task in the start task. So I executed it step by step and entered the creation function. I found that the creation wa...
zhaofan0505 Embedded System
I'm looking for a master with development experience in CE5.0 to help me develop a simple program. Thank you in advance... Urgent
I have a project to scan RFID with PDA. I have experience in program development. I am quite smart. I need some advice from a senior. Please leave your QQ contact information. Thank you. It is urgent....
过云雨 Embedded System
CircuitPython 4.0.2 released
As the most important branch of micropython, CircuitPython has released version 4.0.2, which is the second bug-fix version of 4.x.New fixes since 4.0.1Fix wrong gc of root display groups causing crash...
dcexpert MicroPython Open Source section
Implementation of FIR filter based on FPGA
A scheme for realizing the hardware circuit of linear FIR digital filter by using field programmable gate array device FPGA and window function method is proposed, and the design process using Xilinx ...
zzzzer16 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2055  2625  1854  2732  443  42  53  38  56  9 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号