EEWORLDEEWORLDEEWORLD

Part Number

Search

3EQ1_1

Description
120 V, 50/60 HZ, SINGLE PHASE EMI FILTER
CategoryPassive components   
File Size393KB,2 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet Parametric View All

3EQ1_1 Overview

120 V, 50/60 HZ, SINGLE PHASE EMI FILTER

3EQ1_1 Parametric

Parameter NameAttribute value
working frequency50/60 HZ
stateACTIVE
Installation typePANEL MOUNT
DimensionsL153.2XB52.6XH57.9 (mm)/L6.03XB2.07XH2.28 (inch)
Manufacturer SeriesQ
high capacity2250 V
filter typeSINGLE PHASE EMI FILTER
Rated current20 A
Rated voltage120 V
Maximum leakage current0.7300 mA
Maximum insertion loss frequency70 dB
Minimum insertion loss frequency6 dB
CORCOM Product Guide
Highest Performance RFI Filters for Switching Power Supply
Emissions down to 10 kHz
Q Series
Q8-6A
UL Recognized
CSA Certified
VDE Approved
Q1
Q3
Q Series
This series of RFI power line filters has been developed
specifically for switching power supplies and is designed to
be all the power line filtering needed to control conducted
emissions
all the way down to 10kHz.
High attenuation is
provided for both common mode and differential mode
interference throughout the frequency range with no
degradation of performance due to the large peak currents
drawn by switching power supplies.
These filters are an ideal choice for applications that must
meet emission limits below 150kHz, as well as the
mandated limits above 150kHz. In most cases they will
bring such equipment into compliance with the B-level
limits of CISPR 22. They are also well suited for bringing
ISM equipment (such as ultrasonic cleaners) into
compliance with the limits of FCC Part 18, from 10kHz to
30MHz.
The EQ models meet the very low leakage current
requirements VDE portable equipment, and (120 Volt)
UL544 non-patient medical equipment. The VQ models
offer higher common mode performance at the expense of
higher leakage current, but still meet the leakage current
limits of UL, CSA, and VDE non-portable equipment.
Specifications
Maximum leakage current,each line-to-ground
VQ Models
@ 120 VAC 60 Hz (3A, 20A):
.73 mA
@ 120 VAC 60 Hz (6A):
@ 250 VAC 50 Hz (3A, 20A):
1.27 mA
@ 250 VAC 50 Hz (6A):
Hipot rating (one minute):
line-to-ground
line-to-line
Operating frequency:
Rated voltage (max.):
Rated current:
3VQ/3EQ
6EQ
20EQ1/20VQ1
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Rating
3VQ
3EQ
6EQ
20EQ1
20VQ1
LOAD
EQ Models
.22 mA
.29 mA
.38 mA
.51 mA
2250 VDC
1450 VDC
50/60 Hz
250 VAC
3A
6A
20A
.01
22
22
26
6
6
Frequency–MHz
.02 .05 .15 .5
1
5
27
27
31
10
3
37
36
20
8
17
50
47
68
39
52
55
47
72
60
65
55
43
72
65
70
55
45
65
65
70
10
50
45
65
65
70
30
55
45
65
55
70
Electrical Schematics
3EQ & 3VQ Models
LINE
Line-to-line in 50 ohm circuit
Current
Rating
3VQ
3EQ
6EQ
20EQ1
20VQ1
.01
1
1
6
15
15
Frequency–MHz
.02 .05 .15 .5
1
5
17
17
10
20
20
42
42
43
20
20
65
65
70
46
46
75
75
75
65
65
75
75
75
70
70
60
65
65
65
65
10
65
65
55
60
60
30
65
60
55
60
60
6EQ & 20EQ Models
LINE
LOAD
Line Cord
Resistor location for reference only.
Line Cord No. GA400: 7 1/2 foot, 3-conductor line cord
to mate with Q8 models.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
82
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Power indicator
I want to make a power bank board recently. All functions are working fine now, but the problem of the power indicator light is a bit difficult to solve. It is not easy to solve because the battery vo...
雨后的梧桐 Analog electronics
"Beep, beep,..." alarm sound
[b]1. Experimental task[/b]Use AT89S51 single-chip microcomputer to generate "beep, beep,..." alarm sound and output it from P1.0 port. The frequency is 1KHz. According to the figure above, we can kno...
songbo DIY/Open Source Hardware
Let's take a look at the biogas power generation system for food waste treatment business
JFE Engineering announced on September 6, 2010 that it had received an order for a biogas power generation system for food waste treatment business in Zhengzhou, Henan Province. The system can use foo...
gina Power technology
BeagleBone Development Software Installation Process
The MM at EEWORLD is really efficient. I received the BEAGLEBONE development board the next day after I made a phone call.When you open the package, you will find: a BEAGLEBONE development board, two ...
zhdphao DSP and ARM Processors
Last day! If you don't do this, your electric car will not be able to drive on the road
Electric bicycles have become the favorite of the general public for travel due to their lightness, flexibility and compactness. Whenever the rush hour comes, the unimpeded electric bicycles save many...
EEWORLD社区 TI Technology Forum
8 Embedded C Language Tips Circulated on the Internet
[C Programming Language]. The.C.Programming.Language...
zhangkai0215 Programming Basics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1029  1175  1151  337  2512  21  24  7  51  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号