EEWORLDEEWORLDEEWORLD

Part Number

Search

LLNRK1.40

Description
Electric Fuse, Time Delay Blow, 1.4A, 250VAC, 125VDC, 20000A (IR), Inline/holder,
CategoryCircuit protection    Circuit protection   
File Size405KB,3 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet Parametric View All

LLNRK1.40 Overview

Electric Fuse, Time Delay Blow, 1.4A, 250VAC, 125VDC, 20000A (IR), Inline/holder,

LLNRK1.40 Parametric

Parameter NameAttribute value
MakerLittelfuse
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresRATED BREAKING CAPACITY AT 125 VDC: 20000
Fusing characteristicsTIME DELAY
body height50.8 mm
Body length or diameter14.3 mm
Circuit protection typeELECTRIC FUSE
Installation featuresINLINE/HOLDER
physical size14.3mm x 50.8mm
Rated breaking capacity20000 A
Rated current1.4 A
Rated voltage (AC)250 V
Rated voltage (DC)125 V
surface mountNO
Terminal shapeEND CAP
POWR-GARD
®
Fuse Datasheet
Class RK1 – llNRK • llsRK • llsRK_ID seRIes FUses
250/600 Vac • Dual Element • Time-Delay •
1
/
10
-600 A
QPL
Ordering Information
15 100
/
/
2
/
10
1
/
4
3
/
10
4
/
10
1
/
2
6
/
10
8
/
10
1 10
1
1
1
/
8
1
1
/
4
1
4
/
10
1
6
/
10
1
8
/
10
2
2
1
/
4
2
1
/
2
ampeRe RatINgs
2 /
6
1
/
4
25
3
7
30
3
2
/
10
8
35
3
1
/
2
9
40
4
10
45
4
1
/
2
12
50
5
15
60
5
6
/
10
17
1
/
2
70
6
20
75*
8 10
80
90
100
110
125
150
175
200
225
250
300
350
400
450
500
600
Note: All LLSRK_ID fuses rated 1 amp and above are Indicator
®
fuses.
*75 A is only available for the 600 V.
600 V
type
seRIes
LLSRK_ID
LLSRK
Amp
60
60
Description
RK1 fuses are extremely current-limiting fuses meaning they
greatly reduce or eliminate damage to circuits and equipment under
short-circuit conditions. Replacing existing Class H, K and RK5 fuses
with RK1 fuses is one of the easiest ways to immediately improve
the protection of plant workers and equipment.
INDICAtING
NON-INDICAtING
Catalog
NUmbeR
LLSRK060ID
LLSRK060
Catalog
NUmbeR
LLNRK080
oRDeRINg
NUmbeR
LSRK060.tXID
LSRK060.t
oRDeRINg
NUmbeR
LNRK080.V
250 V
type
NON-INDICAtING
seRIes
LLNRK
Amp
80
Applications
All general purpose circuits
Motors
Transformers
Safety upgrades
Web Resources
Download TC Curves, CAD drawings and other technical
information:
littelfuse.com/llsrk
littelfuse.com/llnrk
Dimensions
Please refer to the Class R dimensions page 3.
Features/Benefits
POWR-PRO Performance
Indication available
Dual-element design
Extremely Current-Limiting
IEC Type 2 “No Damage” protection to IEC and NEMA
type motor starters
• Indicating and DIN mount fuse holders available
Peak Let-Thru Curve (600 V)
LLSRK
1000000
100000
500 A
400 A
200 A
10000
100 A
60 A
30 A
Voltage Ratings
Interrupting Ratings
Ampere Range
Approvals
600 Vac/300 Vdc (LLSRK/LLSRK_ID)
250 Vac/125 Vdc (LLNRK)
AC: 200 kA rms symmetrical
300 kA rms symmetrical
(Littelfuse self-certified)
DC: 20 kA
1/10 – 600 A
AC: Standard 248-12, Class RK1
UL Listed (File: E81895)
CSA Certified (File: LR29862)
DC: Littelfuse self-certified
Federal Specification WF-1814
(QPL- W-F-1814)
PEAK LET-THRU IN AMPERES
Specifications
1000
100
100
1000
10000
100000
200000
Recommended Fuse Holders
LFR60 Series • LFR25 Series
littelfuse.com
AVAILABLE FAULT CURRENT
SYMMETRICAL R.M.S. AMPERES
Note: For more information, see Peak Let-Thru Table
1 of 3
© 2014 Littelfuse POWR-GARD
®
Products
Rev: 040913

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1101  1425  1815  2390  2770  23  29  37  49  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号