800-008-06ZN8-13SY

Description
Circular Connector, 13 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Plug,
CategoryThe connector    The connector   
File Size160KB,2 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

800-008-06ZN8-13SY Overview

Circular Connector, 13 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Plug,

800-008-06ZN8-13SY Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Factory Lead Time17 weeks 1 day
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typePLUG
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
OptionsGENERAL PURPOSE
Shell surfaceZINC-NICKEL WITH CHROMATE
Shell materialALUMINUM ALLOY
Housing size8
Termination typeCRIMP
Total number of contacts13
A
B
C
Series 800 Plug Connector
D
E
F
G
H
J
K
L
800-009
Knurled Round
Plug with
Accessory
Thread
M
Series 800
Series 800 “Mighty Mouse”
Original UNF Threaded Coupling
Series 800 Plug Connectors
Compact Size
saves space and
weight. Smaller than other Series 80
plugs, these Series 800 plugs are
suitable for hostile environments and
are watertight when mated.
Two Shell Styles:
Integral platform for
direct shield attachment using
BAND-
IT
®
termination system, or accessory
thread for attaching a strain relief.
Crimp, Rear Release
contact system,
now with #12 and #16 M39029 coaxial
or power contacts.
Two Coupling Nut Styles:
Hex nut
or round knurled nut. Either style is
available with optional wave spring
which helps to prevent the nut from
backing off.
HOW TO ORDER
Sample Part Number
800-006
Series
-06
Shell Style
-06
Standard
Coupling Nut
M
Shell Material / Finish
C
7-10
Shell Size- Insert
Arrangement
3 #23 Contacts
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
37 #23 Contacts
P
Contact Type
Standard #23 contacts
accept #22 through
#28 AWG wire. Use the
following contact codes to
specify these contacts:
Z
Shell Key
Position
N
Normal
800-006
Hex Plug with
Banding Platform
-16
Coupling Nut
with Anti-
Decoupling
Wave Spring
800-007
Hex Plug with
Accessory
Thread
5-3
Aluminum / Black Anodize
6-1
M
6-4
Aluminum / Electroless
6-7
Nickel
7-1
NF
7-10
Aluminum / Cadmium with
8-13
Olive Drab Chromate
9-4
ZN
9-19
Aluminum / Zinc-Nickel with
10-26
Olive Drab Chromate
12-2
ZNU
12-37
Aluminum / Zinc-Nickel with
Black Chromate
X
Pos. X
P
Pin
Y
Pos. Y
S
Socket
Z
Pos. Z
Z1
Stainless Steel / Passivated
Special contacts for
#26 to #30 AWG are
also available. Use the
#23 contacts are packaged following contact codes to
specify these contacts:
with connectors. #16 and #12
contacts must be ordered
G
separately.
Pin
800-008
Knurled Round
Plug with Band
Platform
H
Socket
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
C-4
Rev. 05-APR-2007
E-Mail: sales@glenair.com
ucosiii freezes after running some programs in a task
I am using ucosiii + ewinGUI and have created multiple tasks. In one of the tasks, I plan to implement a small algorithm. The serial port prints information showing that the task has been started. How...
nf_xx Real-time operating system RTOS
My blog was deleted. Please tell me why.
The day before yesterday, I published a pure English blog about DS coding. I had never come across this kind of coding before, so I wanted to write it down in my blog. I would come and have a look whe...
逆风行 Suggestions & Announcements
C2000 Data Collection
The information I collected during the 2010 Jiangsu Province TI Analog Circuit Design Competition has nothing to do with the competition. Some of the information about C2000 in the TI official CD is t...
恭梧溪 Microcontroller MCU
[Showing sample photos] It turns out that Ti can no longer log in under XP.
[i=s]This post was last edited by johnrey on 2015-9-28 12:55[/i] [size=4]Last time, I encountered an electronic design competition, so I didn’t dare to apply casually. Hoho, let’s continue this time. ...
johnrey TI Technology Forum
MSP430F5438
The program can be downloaded and run, but the crystal oscillator does not oscillate. Neither the low frequency nor the high frequency oscillates. There is no response when using an oscilloscope to me...
chenchaohua99 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2300  2178  40  544  603  47  44  1  11  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号