Snap Acting/Limit Switch, SPST, Momentary, 23.34mm, Quick Connect Terminal, Straight Type Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size114KB,2 Pages
ManufacturerThe Cherry Corporation
Download Datasheet Parametric View All

KWEARAAG Overview

Snap Acting/Limit Switch, SPST, Momentary, 23.34mm, Quick Connect Terminal, Straight Type Actuator, Panel Mount

KWEARAAG Parametric

Parameter NameAttribute value
MakerThe Cherry Corporation
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator stroke23.34 mm
Actuator typeSTRAIGHT TYPE
body width10.31 mm
body height15.88 mm
Body length or diameter28.96 mm
Contact (AC) maximum rated R load3A@250VAC
Maximum contact current (AC)3 A
Maximum contact voltage (AC)250 V
Electrical life100000 Cycle(s)
Manufacturer's serial numberK
Installation featuresPANEL MOUNT
Maximum operating force0.04 N
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Maximum pre-travel13.01 mm
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeQUICK CONNECT
MINIATURE
K Series
Features
Choice of current ratings up to 25 amps
Choice of actuators
Choice of terminals
3 contact arrangements
Choice of operating force
Long mechanical life
Wiping contact action
Snap over actuators
Agency approved extended life versions
Flame retardant, UL94V-O
self-extinguishing
case and cover
Long-life snap action
switch mechanism
ARC-resistant case
has internal barriers,
4mm minimum between
live parts and external
hardware
NC terminal
NO terminal
International Approved Versions
K Series switches, except 25A (KWS), are
internationally approved. Switches with
straight terminals may require insulated
connectors for international approval.
Choice of U.S. (#4 screw)
or metric (3mm screw)
Common terminal
Single or double throw, either
normally open or normally closed
Electrical Ratings
Switch
Series
EN61058 Rating
UL1054 Rating
Electrical Life at Rated Load
According to VDE
According to UL
(Min. Operations)
(Min. Operations)
KWA/KWB
KWC/KWD
KWE/KWF
KWG/KWH
KWJ/KWK
KWL
50mA, 28VDC
1(0.5)A, 250VAC
3(1)A, 250VAC
6(2)A, 250VAC
10(3)A, 250VAC
N/A
KWM
16(4)A, 250VAC
KWS
N/A
50mA, 28VDC
1.0A, 125/250VAC
3A, 1/10HP, 125/250VAC
5A, 1/4HP, 125/250VAC
10A, 1/2HP, 125/250VAC
15.1A, 1/2HP, 125/250 VAC
5A, 125VAC Lamp Load
(85°C only)
0.5A, 125VDC
(85°C only)
0.25A, 250VDC
(85°C only)
15.1A, 1/2HP, 125/250VAC
0.5A, 125VDC
(85°C and 150°C only)
0.25A, 250VDC
(85°C and 150°C only)
15.1A, 1/2HP, 125/250VAC
(200°C only)
25A, 125/250VAC
(85°C only)
1HP, 125VAC
(85°C only)
2HP, 250VAC
(85°C only)
50,000
50,000
50,000
50,000
50,000
N/A
100,000
100,000
100,000
100,000
100,000
100,000
50,000
100,000
N/A
100,000
Specifications
Electrical
Temperature Rating:
Flammability Rating:
Materials
-40° to +85°C, 150°C or 200°C
UL94V-O
Thermoplastic Polyester (85°C or 150°C)
Liquid Crystal Polymer (200°C)
Thermoplastic Acetal (85°C)
Thermoplastic Polyester (150°C)
Liquid Crystal Polymer (200°C)
Cold-Rolled Steel (Nickel-Plated)
Brass
Copper (25 amp only)
Beryllium Copper
Silver Alloy
(except KWA and KWB — Gold-Plated)
Case/Cover:
Button:
Auxiliary Actuator:
Terminals:
Moving Blade:
Contacts:
I would like to ask you a small question about OrCAD Capture CIS
I'm not very familiar with it. I have a small question. When making components, I use SpreadSheet to place the pins in the Top and Right directions. How can I change the order of the pin numbers from ...
wenzheng PCB Design
Msp430f5529 car source code exchange
#includemsp430f5529.h?unsigned?int?mode_flag=0xffff;void??Init_PWM_Driver()?//?Initialize the motor drive circuit{???P4DIR?|=BIT0+BIT1+BIT2+BIT3;?//IN1~IN4???P2DIR?|=BIT0+BIT1;//Reuse p2.0 as the enab...
fish001 Microcontroller MCU
FPGA implements UART transceiver
[code] module UART (rst,clk50M,send_en,rev_en,TXD,TXD_data,RXD,RXD_data); input rst,clk50M,RXD,send_en,rev_en; input [7:0] TXD_data; output TXD; reg TXD; reg [ 7:0] TXD_cnt; output [7:0] RXD_data; reg...
k331922164 FPGA/CPLD
Encountered a weird problem.
The VC code was ported to EVC4.0. The compilation was fine, but the screen could not be displayed normally. The graphics were drawn in the ONDRAW function, which was about 20,000 lines. So I added it ...
wj54321 Embedded System
Why can't my CCS 5.2 exit DEBUG?
When debugging the target C2000, you can enter the DEBUG mode and debug normally, but you can't exit. When you click the exit button (the red square), it freezes. You have to close it. It's very troub...
dontium Microcontroller MCU
Difference Between Oscillator and Resonator
[p=30, null, left][font=宋体][size=3][color=#111111] [/color][color=#000000]In the past, resonators and oscillators were often confused. After some time of comparison, I roughly sorted it out. We are us...
Aguilera Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1393  2392  216  1379  1807  29  49  5  28  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号