EEWORLDEEWORLDEEWORLD

Part Number

Search

50120050130G

Description
Barrier Strip Terminal Block
CategoryThe connector    terminals   
File Size293KB,1 Pages
ManufacturerAPEM
Download Datasheet Parametric Compare View All

50120050130G Overview

Barrier Strip Terminal Block

50120050130G Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
ECCN codeEAR99
Manufacturer's serial number50120
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Base Number Matches1
Wire Guard |
Spacing 5.08 mm
AKZ120/..DS-5.08-H-GREY
Technical Data
Wire Sizes
Solid min
solid max
Stranded (flexible)
min
Stranded (flexible)
max
0.2 mm²
4.0 mm²
0.2 mm²
2.5 mm²
Insulating Material
Material
Flammability Class
Temperatures
Operating Temperature
Wave Soldering Process
Soldering Temperature,
recommended
Peak Soldering Time,
recommended
Reflow Process
Soldering Temperature,
recommended
Peak Soldering Time,
recommended
Leere Zeile
-
-
265 °C
3-4 s
-30 °C - 105 °C
PA 6.6
UL 94 V-0
Order Data (Spacing mm)
Poles
2
3
4
5
6
7
8
9
10
11
12
Width (mm)
10.86
15.94
21.02
26.10
31.18
36.26
41.34
46.42
51.50
56.58
61.66
Article Designation
AKZ120/2DS-5.08-H-GREY
AKZ120/3DS-5.08-H-GREY
AKZ120/4DS-5.08-H-GREY
AKZ120/5DS-5.08-H-GREY
AKZ120/6DS-5.08-H-GREY
AKZ120/7DS-5.08-H-GREY
AKZ120/8DS-5.08-H-GREY
AKZ120/9DS-5.08-H-GREY
AKZ120/10DS-5.08-H-GREY
AKZ120/11DS-5.08-H-GREY
AKZ120/12DS-5.08-H-GREY
Article Number
50120020130G
50120030130G
50120040130G
50120050130G
50120060130F
50120070130F
50120080130E
50120090130E
50120100130E
50120110130E
50120120130E
PU
250
250
250
250
200
200
100
100
100
100
100
Stranded with Ferrule 0.2 mm²
min
Stranded with Ferrule 2.5 mm²
max
Dimensions
Stripped Length
PCB Hole Diameter
Materials
Clamp
Wire Guard
Screw
Brass
Stainless Steel
Steel
6.0 mm
1.3 mm
Accessories
Figure
Designation
Bridge, 2-pole, insulated, BRI/2-5.0/5.08-
LIGHT GREY
Article Number
50000000006
Colours
GREY
BLUE
RAL7016
RAL5015
RAL7016
Bridge, 3-pole, insulated, BRI/3-5.0/5.08-
LIGHT GREY
50000000007
RAL5015
Colours according to RAL, there may be variations on colour due to production conditions.
Special colours on request.
Bridge, 2-pole, BR/2-5.0/5.08-L7.0
50000000008
Ratings
Usegroup
Rated Voltage
Rated Current
Rated Wire Size
solid
stranded
Torque
Screw Size
Test Voltage
B
300 V
20 A
AWG 22-12
AWG 22-12
0.45 Nm
M3
1.6 kV
C
150 V
20 A
AWG 22-12
AWG 22-12
0.45 Nm
M3
1.6 kV
D
300 V
10 A
AWG 22-12
AWG 22-12
0.45 Nm
M3
1.6 kV
min
0.5 mm²
0.5 mm²
250 V
24 A
max
2.5 mm²
2.5 mm²
0.50 Nm
M3
2.0 kV

50120050130G Related Products

50120050130G 50120100130E 50120110130E 50120120130E
Description Barrier Strip Terminal Block Barrier Strip Terminal Block Barrier Strip Terminal Block Barrier Strip Terminal Block
Reach Compliance Code compli compliant compliant compliant
ECCN code EAR99 EAR99 EAR99 EAR99
Manufacturer's serial number 50120 50120 50120 50120
Terminal and terminal strip types BARRIER STRIP TERMINAL BLOCK BARRIER STRIP TERMINAL BLOCK BARRIER STRIP TERMINAL BLOCK BARRIER STRIP TERMINAL BLOCK
Maker - APEM APEM APEM
Looking for a C language code to convert the solar calendar to the lunar calendar
I'm making an electronic clock recently and need to convert the Gregorian calendar to the lunar calendar (2000-2099), so I came here for help....
孤獨の快樂 51mcu
Evolution or extinction? Let's take a look at the present and future of human-computer interaction represented by the mouse
[align=center][align=left]Since the initial prototype was developed in 1963, the mouse has been used as a computer input device for more than 50 years. Its appearance laid a solid technical foundation...
1977650578 Robotics Development
Minimum conditions for lead-acid batteries to start the starter motor
[align=left][size=3][color=#000000]The minimum conditions for the lead-acid battery to start the starter motor[/color][/size][/align] [align=left][font=Calibri][size=3][color=#000000] [/color][/size][...
Riku815 Power technology
Which textbook is better for learning Linux?
Which textbook is better for learning Linux?...
F15933643527 Linux and Android
I find studying difficult. What should I do?
Everything is difficult at the beginning. It is normal to feel that learning the science of radio is difficult in the initial stage. Problems such as not being able to understand and remember are inev...
lhy FPGA/CPLD
I want to use an op amp to do a step-down process, but I need to collect a voltage value of the us level in the nonlinear voltage.
Because the collected voltage exceeds the input range of the ADC, Now I want to use an op amp to do a voltage step-down process, but I need to collect a voltage value of the us level in the non-linear...
安_然 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 121  28  621  665  450  3  1  13  14  10 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号