Transient Voltage Suppressors
TransGuard
®
Surface Mount
l
HOW TO ORDER
V C 1206 05 D 150 R
12 3 4 5 6 7
1
Product Designator:
V = Varistor (TransGuard
®
)
2
Case Designator:
C = Chip
3
Case Size Designator
4
Working Voltage:
Where: 03 = 3.3VDC; 14 = 14.0VDC; 30 = 30.0VDC;
05 = 5.6VDC; 18 = 18.0VDC; 48 = 48.0VDC;
09 = 9.0VDC; 26 = 26.0VDC; 60 = 60.0VDC
5
Energy:
Where: A = 0.1J; D = 0.4J; G = 0.9J; K = 2.0J;
B = 0.2J; E = 0.6J; H = 1.2J; V = 0.02J;
C = 0.3J; F = 0.7J; J = 1.5J; X = 0.05J
6
Clamping Voltage:
Where: 100 = 10.0V; 200 = 20.0V; 560 = 56.0V;
101 = 100.0V; 300 = 30.0V; 580 = 58.0V;
121 = 120.0V; 390 = 39.0V; 620 = 62.0V;
150 = 15.5V; 400 = 40.0V; 650 = 65.0V;
7
Standard Packaging
(Pcs/Reel):
Style
D
R
T
VC0402
VC0603
VC0805
VC1206
VC1210
0805
3.3, 5.6, 9, 12, 14, 18, 26
or 30VDC
2.01±0.2 (0.79±.008)
1.25±0.2 (.049±.008)
1.02 max. (.040)
0.71 max. (.028)
-
-
Pt/Pd/Ag
T
L
W
Voltage and Dimensions:
millimeters (inches)
Case Size
Voltages
Actual Size
Length
(L)
Width
(W)
Thickness
(T)
Land Length
(l)
Termination Band Width
Termination Separation
Termination Finish*
–
1,000
1,000
1,000
1,000
4,000
4,000
4,000
4,000
2,000
1210
10,000
10,000
10,000
10,000
10,000
0402
5.6, 9.0, 14.0
or 18VDC
1.00±0.10 (.040±.004)
.50±0.10(.020±.004)
.60 max. (.024)
-
.25±0.15 (.010±.006)
.30 (0.12) min.
Pt/Pd/Ag
0603
3.3, 5.6, 9.0, 14, 18, 26
or 30VDC
1.6±0.15 (.063±.006)
0.8±0.15 (.032±.006)
0.9 max. (.035)
-
.035±0.15 (.014±.006)
0.7 (.028) min.
Pt/Pd/Ag
1206
3.3, 5.6, 14, 18, 26, 30
or 48VDC
3.20±0.2 ( .126±.008)
1.60±0.2 (.063±.008)
1.70 max. (.067)
0.71 max. (.028)
-
-
Pt/Pd/Ag
18, 26, 30, 48
or 60VDC
3.20±0.6 ( .126±.008)
2.49±0.2 (.098±.008)
1.70 max. (.067)
0.71 max. (.028)
-
-
Pt/Pd/Ag
*For Ni terminations contact factory.
0402 Surface Mount
AVX Part Number
Symbol
Units
Test Condition
VC040205X150
VC040209X200
VC040214X300
VC040218X400
AVX Part Number
Symbol
Units
Test Condition
VC060303A100
VC060305A150
VC060309A200
VC060314A300
VC060318A400
VC060326A580
VC060330A650
Working Voltage
V
WM
Volts (max.)
<50µA
5.6
9.0
14.0
18.0
Breakdown Voltage
V
B
Volts
1mA DC
7.6 ~ 9.3
11.0 ~ 14.0
16.5 ~ 20.3
22.9 ~ 28.0
Clamping Voltage
V
C
Volts (max.)
8/20µS†
15.5
20.0
30.0
40.0
Peak Current
I
peak
Amp. (max.)
8/20µs
20
20
20
20
Transient Energy
E
trans
Joules (max.)
10/1000µS
0.05
0.05
0.05
0.05
Capacitance
C
pF (typ.)
0.5Vrms @:
1MHz
360
230
120
90
Inductance
L
nH (typ.)
di/dt = 100mA/nS
<1
<1
<1
<1
0603 Surface Mount
Working Voltage
V
WM
Volts (max.)
<50µA
3.3
5.6
9.0
14.0
18.0
26.0
30.0
Breakdown Voltage
V
B
Volts
1mA DC
4.1 ~ 6.0
7.6 ~ 9.3
11.0 ~ 14.0
16.5 ~ 20.3
22.9 ~ 28.0
31.0 ~ 38.0
37.0 ~ 46.0
Clamping Voltage
V
C
Volts (max.)
8/20µS†
10
15.5
20
30
40
58
65
Peak Current
I
peak
Amp. (max.)
8/20µs
30
30
30
30
30
30
30
Transient Energy
E
trans
Joules (max.)
10/1000µS
0.1
0.1
0.1
0.1
0.1
0.1
0.1
Capacitance
C
pF (typ.)
0.5Vrms @:
1kHz
1MHz
1800
1230
1000
825
650
550
500
425
275
225
200
160
175
150
Inductance
L
nH (typ.)
di/dt = 100mA/nS
<1.0
<1.0
<1.0
<1.0
<1.0
<1.0
<1.0
Additional information on this product is available from AVX’s catalog or AVX’s FAX Service. Call 1-800-879-1613 and request document
#100.
Visit our website http://www.avxcorp.com
100
Transient Voltage Suppressors
TransGuard
®
Surface Mount
(continued from pg. 100)
0805 Surface Mount
AVX Part Number
Symbol
Units
Test Condition
VC080503A100
VC080503C100
VC080505A150
VC080505C150
VC080509A200
VC080512A250
VC080514A300
VC080514C300
VC080518A400
VC080518C400
VC080526A580
VC080526C580
VC080530A650
Working Voltage
V
WM
Volts
(max.)
<50µA
3.3
3.3
5.6
5.6
9
12
14
14
18
18
26
26
30
Breakdown Voltage
V
B
Volts
1mA DC
4.1 ~ 6.0
3.7 ~ 5.6
7.6 ~ 9.3
7.1 ~ 8.7
11.0 ~ 14.0
14.0 ~ 18.3
16.5 ~ 20.3
15.9 ~ 19.4
22.9 ~ 28.0
22.5 ~ 27.5
31.0 ~ 37.9
30.5 ~ 37.3
37.0 ~ 46.0
Clamping Voltage
V
C
Volts
(max.)
8/20µS†
10
10
15.5
15.5
20
25
30
30
40
40
58
58
65
Peak Current
I
peak
Amp.
(max.)
8/20µs
40
120
40
120
40
40
40
120
30
100
30
100
30
Transient Energy
E
trans
Joules
(max.)
10/1000µS
0.1
0.3
0.1
0.3
0.1
0.1
0.1
0.3
0.1
0.3
0.1
0.3
0.1
Capacitance
C
pF
(typ.)
0.5Vrms @:
1kHz
1MHz
1300
5500
1250
3500
780
525
375
1100
350
650
140
250
100
930
4000
860
2400
585
400
280
820
275
500
110
190
80
Inductance
L
nH
(typ.)
di/dt = 100mA/nS
<1.5
1.5
<1.5
1.5
<1.5
<1.5
<1.5
1.5
<1.5
1.5
<1.5
1.5
<1.5
1206 Surface Mount
AVX Part Number
Symbol
Units
Test Condition
VC120603A100
VC120603D100
VC120605A150
VC120605D150
VC120614A300
VC120614D300
VC120618A400
VC120618D400
VC120626D580
VC120630D650
VC120648D101
Working Voltage
V
WM
Volts
(max.)
<50µA
3.3
3.3
5.6
5.6
14
14
18
18
26
30
48
Breakdown Voltage
V
B
Volts
1mA DC
4.1 ~ 6.0
3.7 ~ 5.6
7.6 ~ 9.3
7.1 ~ 8.7
16.5 ~ 20.3
15.9 ~ 19.4
22.9 ~ 28.0
22.5 ~ 27.5
30.5 ~ 37.3
36.0 ~ 45.0
56.0 ~ 68.0
Clamping Voltage
V
C
Volts
(max.)
8/20µS†
10
10
15.5
15.5
30
30
40
40
58
65
100
Peak Current
I
peak
Amp.
(max.)
8/20µs
40
150
40
150
40
150
30
150
120
120
100
Transient Energy
E
trans
Joules
(max.)
10/1000µS
0.1
0.4
0.1
0.4
0.1
0.4
0.1
0.4
0.4
0.4
0.4
Capacitance
C
pF
(typ.)
0.5Vrms @:
1kHz
1MHz
2000
1500
4700
3800
1200
3000
600
1200
350
800
550
500
225
870
2300
500
900
270
635
450
400
185
Inductance
L
nH
(typ.)
di/dt = 100mA/nS
<1.7
1.7
<1.7
1.7
<1.7
1.7
<1.7
1.7
1.7
1.7
1.7
1210 Surface Mount
AVX Part Number
Symbol
Units
Test Condition
VC121018J390
VC121026H560
VC121030G620
VC121030H620
VC121048G101
VC121048H101
VC121060J121
See note page 103
Working Voltage
V
WM
Volts
(max.)
<50µA
18
26
30
30
48
48
60
Breakdown Voltage
V
B
Volts
1mA DC
21.5 ~ 26.5
29.7 ~ 36.3
35.0 ~ 43.0
35.0 ~ 43.0
54.5 ~ 66.5
54.5 ~ 66.5
67.0 ~ 83.0
Clamping Voltage
V
C
Volts
(max.)
8/20µS†
39
56
62
62
100
100
120
Peak Current
I
peak
Amp.
(max.)
8/20µs
500
300
220
280
220
250
250
Transient Energy
E
trans
Joules
(max.)
10/1000µS
1.5
1.2
0.9
1.2
0.9
1.2
1.5
Capacitance
C
pF
(typ.)
0.5Vrms @:
1kHz
1MHz
3100
2150
1900
1975
500
525
450
2400
1675
1530
1575
430
450
375
Inductance
L
nH
(typ.)
di/dt = 100mA/nS
2.0
2.0
2.0
2.0
2.0
2.0
2.0
Additional information on this product is available from AVX’s catalog or AVX’s FAX Service.
Call 1-800-879-1613 and request document
#101.
Visit our website http://www.avxcorp.com
101
Transient Voltage Suppressors
TransGuard
®
Axial Lead
D
Max.
Lead
Diameter
L
Max.
Lead Length
Min.
HOW TO ORDER
V A 1000 03 D 100 R
1 2 3 4 5 6 7
1
Product Designator:
V = Varistor (TransGuard
®)
2
Case Designator:
A = Axial
3
Case Size Designator
4
Working Voltage:
Where: 03 = 3.3VDC; 26 = 26.0VDC;
05 = 5.6VDC; 30 = 30.0VDC;
14 = 14.0VDC; 48 = 48.0VDC;
18 = 18.0VDC; 60 = 60.0VDC
5
Energy:
Where: A = 0.1J; D = 0.4J; G = 0.9J; K = 2.0J;
B = 0.2J; E = 0.6J; H = 1.2J; V = 0.02J;
C = 0.3J; F = 0.7J; J = 1.5J; X = 0.05J
6
Clamping Voltage:
Where: 100 = 10.0V; 300 = 30.0V;
101 = 100.0V; 400 = 40.0V;
121 = 120.V; 580 = 58.0V;
150 = 15.5V; 650 = 65.0V2
7
Standard Packaging (Pcs/Reel):
Style
D
R
T
VA1000 1,000 3,000 7,500
VA2000 1,000 2,500 5,000
Peak Current
I
peak
Amp.
(max.)
8/20µs
40
150
40
150
40
150
40
150
120
120
100
300
VA1000
Body Length
Body Diameter
Lead Diameter
Lead Length
(L) = 4.32mm.
(170" Max.)
(D) = 2.54mm
(.100" Max.)
0.51 ± .05mm
(.020 ± .002)
25.4mm
(1" Min.)
VA2000
4.83mm
(.190" Max.)
3.56mm Max.
(.140")
0.51 ± .05mm
(.020 ± .002)
25.4mm
(1" Min.)
Axial Leaded Devices
AVX Part Number
Symbol
Units
Test Condition
VA100003A100
VA100003D100
VA100005A150
VA100005D150
VA100014A300
VA100014D300
VA100018A400
VA100018D400
VA100026D580
VA100030D650
VA100048D101
VA200060K121
Working Voltage
V
WM
Volts
(max.)
<50µA
3.3
3.3
5.6
5.6
14
14
18
18
26
30
48
60
Breakdown Voltage
V
B
Volts
1mA DC
4.1 ~ 6.0
3.7 ~ 5.6
7.6 ~ 9.3
7.1 ~ 8.7
16.5 ~ 20.3
15.9 ~ 19.4
22.9 ~ 28.0
22.5 ~ 27.5
30.5 ~ 37.3
36.0 ~ 45.0
56.0 ~ 68.0
67.0 ~ 83.0
Clamping Voltage
V
C
Volts
(max.)
8/20µS†
10
10
15.5
15.5
30
30
40
40
58
65
100
120
Transient Energy
E
trans
Joules
(max.)
10/1000µS
0.1
0.4
0.1
0.4
0.1
0.4
0.1
0.4
0.4
0.4
0.4
2.0
Capacitance
C
pF
(typ.)
0.5Vrms @:
1kHz
1MHz
1500
1100
4700
3800
1000
2800
400
1200
350
900
700
600
200
400
750
2150
300
900
270
700
550
500
165
340
Inductance
L
nH
(typ.)
di/dt = 100mA/nS
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
V
WM
—Maximum steady-state DC operating voltage the varistor can maintain and not exceed 50µA leakage current
V
B
—Voltage across the device measured at 1mA DC current
V
C
—Maximum peak voltage across the varistor measured at a specified pulse current and waveform
†Transient Energy Rating
Pulse Current & Waveform
.1 Joule
.2–.3 Joules
≥.4Joules
2A8/20µS
5A 8/20µS
10A 8/20µS
I
peak
—Maximum peak current which may be applied with the specified waveform without device failure
E
Trans
—Maximum energy which may be dissipated with the specific waveform without device failure
C—Device capacitance measured with zero volt bias at .5Vrms and 1kHz
L—Device inductance measured with a current edge rate of 100mA/nS
Dimensions: Millimeters (Inches)
Additional information on this product is available from AVX’s catalog or AVX’s FAX Service.
Call 1-800-879-1613 and request document
#107.
Visit our website http://www.avxcorp.com
107