EEWORLDEEWORLDEEWORLD

Part Number

Search

CA-180

Description
DIGITAL TEMP SENSOR-SINGLE TRIP POINT, ROUND
CategoryThe sensor   
File Size48KB,3 Pages
ManufacturerETC2
Download Datasheet Parametric View All

CA-180 Overview

DIGITAL TEMP SENSOR-SINGLE TRIP POINT, ROUND

CA-180 Parametric

Parameter NameAttribute value
Maximum operating temperature150 Cel
Minimum operating temperature10 Cel
Processing package descriptionROHS COMPLIANT PACKAGE
Lead-freeYes
EU RoHS regulationsYes
stateCONSULT MFR
high10 mm
terminal coatingNOT SPECIFIED
type of packagingROUND
length or diameter16 mm
sensor typeSINGLE TRIP POINT
1 / 2 ” D i s c T h e r m o s ta ts - A u t o m a t i c R e s e t
C A / O A ( 6 0 2 S ) S e r i e s , G o l d C o n ta c ts ( 6 0 2 K )
SPECIFICATIONS
Electrical ratings - Type S
Inductive load ratings
Electrical ratings - Type K
Temperature range
UL approved models
Non-UL approved models
Differential
Environmental temperature
Insulation resistance
Circuit resistance
Dielectric strength
Approvals
125VAC, 15 Amps, Resistive, 100,000 Cycles
250VAC, 10 Amps, Resistive, 100,000 Cycles
120VAC, 5.8FLA, 34.8LRA, 6,000 Cycles
240VAC, 2.9FLA, 17.4LRA, 6,000 Cycles
30VDC, 1 Amp, Resistive, 100,000 Cycles
120VAC, 125VA (pilot duty), 1 Amp
50ºF to 302ºF (10ºC to 150ºC)
302ºF to 320ºF (575ºC to 608ºC)
15ºF to 100ºF (8ºC to 56ºC)
32ºF to 350ºF (0ºC to 177ºC)
100M
S
or more (with a 500VDC megger)
50m
S
or less (initial value)
1,500VAC/1 minute
UL Recognized File No. E145478(S), XAPX2
CSA File No. LR63201
VDE File No. 69046
Demko File No. DK-451, CE
RoHS Compliant
This line of highly reliable switches utilize a temperature sensitive disc, electrically isolated from the switch. Contacts will open
or close on rise when surface or ambient temperature increase to the snap point of the calibrated bimetal disc. The entire switch
is enclosed in a phenolic dust-free housing. The bimetal disc is retained by a metal heat-conducting end cap.
The CA and OA Series thermostats are used in a variety of applications. They are produced in an ISO 9000 certified factory to
insure safe and reliable operation. All models are 100% factory inspected for temperature, continuity and function.
Value Added options available including over-mold and seal. For details regarding Value Added options, see page 51.
Models available from stock - subject to availability
CA - Close On-Rise (normally open)
OA - Open On-Rise (normally closed)
Close/Open
On-Rise
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Close
Model
Number
CA-50
CA-60
CA-60-QCV
CA-85
CA-85-PCB
CA-85-QC
CA-100
CA-104-ST-18
CA-107-QCV
CA-110
CA-110-PCB
CA-110-QC45
CA-115-QC
CA-120
CA-120-QC
CA-120-QCH
CA-120-QCV
CA-130-QC
CA-130-QCH
CA-130-ST
CA-130-WOB
CA-140
CA-140-QC
CA-140-QC18
CA-150
CA-160
CA-160-QC
CA-160-QC15
CA-170
Open ºF
32 ± 10
40 ± 9
40 ± 10
67 ± 9
55 ± 10
67 ± 10
70 ± 10
86 ± 10
90 ± 10
80 ± 10
80 ± 10
80 ± 10
100 ± 10
90 ± 10
90 ± 10
90 ± 10
90 ± 7
110 ± 10
100 ± 10
112 ± 10
100 ± 10
110 ± 10
110 ± 10
122 ± 10
120 ± 10
130 ± 10
130 ± 10
145 ± 7
140 ± 10
Close ºF
50 ± 7
60 ± 7
60 ± 7
85 ± 7
85 ± 7
85 ± 7
100 ± 7
104 ± 8
107 ± 7
110 ± 7
110 ± 7
110 ± 7
115 ± 7
120 ± 7
120 ±7
120 ± 7
120 ± 10
130 ± 7
130 ± 7
130 ± 7
130 ± 7
140 ± 7
140 ± 7
140 ± 7
150 ± 7
160 ± 7
160 ± 7
160 ± 10
170 ± 7
Mounting
surface
surface
surface
surface
air
surface
surface
6-32 stud
surface
surface
air
surface
rotating bracket
surface
surface
surface
surface
surface
surface
8-32 stud
no bracket
surface
surface
rotating
surface
surface
surface
surface
surface
Terminals
solder tabs
solder tabs
.250 quick connects, vertical
solder tabs
printed circuit board
.187 quick connects, horizontal
solder tabs
.250 quick connects, vertical
.187 quick connects, vertical
solder tabs
printed circuit board
.187 quick connects, horizontal
.250 quick connects, horizontal
solder tabs
.250 quick connects, horizontal
.187 quick connects, horizontal
.250 quick connects, vertical
.250 quick connects, vertical
.250 quick connects, horizontal
.250 quick connects, vertical
solder tabs
solder tabs
.250 quick connects, vertical
.250 quick connects, vertical
solder tabs
solder tabs
.250 quick connects, horizontal
.250 quick connects, horizontal
solder tabs
Orientation from
Mounting Holes
45º
45º
90º
45º
45º
45º
90º
45º
45º
45º
90º
45º
90º
45º
90º
45º
45º
90º
45º
45º
90º
90º
45º
I t i s t h e c u s t o m e r ’s s o l e r e s p o n s i b i l i t y t o s p e c i f y a n d d e t e r m i n e t h e s u i ta b i l i t y o f a pa r t i c u l a r
c o n t r o l o r c o m p o n e n t b a s e d o n t h e i r u n i q u e i n d i v i d u a l a p p l i c a t i o n s a n d r e q u i r e m e n ts
(714) 917-1333
(800) 257-3526
FAX (714) 917-1355
E-mail: sales@selcoproducts.com
5
www.selcoproducts.com
Question about the frequency measurement gate time
I'm working on a frequency meter topic for an electronics competition. I've written a frequency measurement program using the direct frequency measurement method and also wrote a testbench for testing...
yyj8902 FPGA/CPLD
How to set up the disassembly window of CCS?
Dear seniors: ==================================== I see in all the books that in ccs, after the executable code .out is loaded, ccs will automatically open a disassembly window. However, the CCS2.0 I...
xinyancode DSP and ARM Processors
Learning to use evc to develop wince programs, do I have to install pb4.2 before installing evc4.0?
The book I started reading is Programming Microsoft Windows CE .NET, Third Edition. I want to practice according to the book. Do I have to install pb4.2 before installing evc4.0?? Thank you!!...
yj3333 Embedded System
Things developers need to know
[Things developers need to knowAuthor: Very Earthy[ Print ][ Return ]I often see a lot of silly questions, such as what is xx language used for, is xxx language out of date? (But to be honest, these q...
fighting Analog electronics
Mental age test
You can also try http://ip.91.com/age.htm...
gaoyanmei Talking
How to convert the password in the registry?
Dear friends, how do I convert the password in the registry? If the password is Bz23HUcIbUwBAAAA, how do I convert it to the real password?...
gxlcgxlc RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1697  2494  554  420  1025  35  51  12  9  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号