Description
Designed to Meet UL544 and IEC601 Specifications for Medical and Dental Equipment
File Size122KB,1 Pages
ManufacturerETC2
Download Datasheet Compare View All

F3099BB06 Overview

Designed to Meet UL544 and IEC601 Specifications for Medical and Dental Equipment

F3099 RFI Filters
Specifications
:
Maximum Voltage:
250VAC Maximum - 50/60 Hz
Rated Current:
250VAC
6A
Current Overload:
6X for 8 seconds
Hi-Pot Test (1 min):
Line to Ground
1500VAC
Line to Line
1450VDC
Insulation Resistance:
9 x 10
9
Ω
at 100VDC
Ambient Temperature:
40°C Max at rated current
Humidity Range:
0% to 95% R.H.
Termination:
A: Quick Connect
B: Wire
Maximum Leakage Current:
Each Line to Ground
F3000 Series
115VAC, 60Hz:
2
μA
250VAC, 50Hz:
5
μA
Agency Approvals:
General Purpose Filtered Modules
Features:
• Designed to Meet UL544 and IEC601 Specifications
for Medical and Dental Equipment, both patient care
and onpatient categories.
• Leakage current in this series is extremely low to
satisfy the stringest leakage current limit imposed by
safety regulations for medical and dental equipment.
F3099AA
(6Amp) Dimensions
Amps
A
2.53
(64,30)
2.53
(64,30)
B
1.82
(46,2)
1.82
(46,2)
C
0.78
(19,8)
0.78
(19,8)
D
2.126
(54,0)
2.126
(54,0)
E
2.53
(64,30)
1.32
(33,5)
LINE
L
G
N
F3099 Series
Simplified Schematic
L
LO A D
N
WIRE LEADS, 18AWG,
(16AWG FOR 10A).
102(4.0) MIN.
BLUE
BLUE
G/Y
BROWN
BROWN
6A
6.36(0.25) FASTON TERMINAL
WITH Ø1.78 (0.070) HOLE
(SLOTTED HOLE
FOR GROUND)
MEDICAL FILTERS
A D
A D
B
B
E
E
C
C
Nominal
Current
Rating
MINIMUM INSERTION LOSS - dB (50 ohm Circuit)
Part
Number
Termination
Line/Load
QC/QC
ø
MODE
Common
Differential
Frequency - MHz
.50
1.0
20
20
22
30
0.05
3
3
0.10
7
6
.15
11
14
5.0
24
35
10
22
35
30
18
35
6A
72
F3099AA06
F3099BB06
NOTE: Other combinations of terminals may be specified on special order.
www.curtisind.com
Curtis Industries
A Division of Powers Holdings, Inc.
Specifications subject to change.
Dimensions are shown for
reference purposes only.

F3099BB06 Related Products

F3099BB06 F3099AA06
Description Designed to Meet UL544 and IEC601 Specifications for Medical and Dental Equipment Designed to Meet UL544 and IEC601 Specifications for Medical and Dental Equipment

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2693  1632  2250  2101  1552  55  33  46  43  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号